CISCO-90-MIB Download
The Cisco 90i Series MIB
IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges,
Firewalls, Repeaters.
OID list for CISCO-90-MIB
- frxSysDescr
- Description of the Cisco 90 Series System.
- frxClockHour
- Synchronized 24 hour clock for the Cisco 90 Series system - Hour. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals.
- frxClockMin
- Synchronized 24 hour clock for the Cisco 90 Series system - Minutes. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals.
- frxClockSec
- Synchronized 24 hour clock for the Cisco 90 Series system - Seconds. This clock is used by the channel units and BRITE cards to set the performance monitoring end-of-hour and end-of-day intervals.
- frxUpTime
- Time since the agent was last initialized in 0.01 second increments.
- frxAdminContact
- Cisco 90 Series administrative contact name.
- frxSysName
- Administratively assigned name for this Cisco 90 Series agent.
- frxSysLoc
- Physical location of the Cisco 90 Series agent.
- frxSysVersion
- Cisco 90 Series Agent version number. The version number is an INTEGER representation of the actual version number string. The way to translate to a version number string is 200 = 2.0.0, 201 = 2.0.1, etc.
- frxUPerfTrapEnable
- 1=Enable sending the frxUPerfTrap trap to the SNMP manager when a performance monitoring threshold is crossed at an Cisco 90 Series channel unit or a downstream BRITE card. 2=Disable Trap.
- frxAgtLinkErrors
- Number of Annex-D signaling link reliability errors between the Cisco 90 Series Agent and the Frame Relay Switch. A signaling reliability error is declared whenever the Cisco 90 Series Agent did not receive a reply from the frame relay switch in response ...
- frxAgtProtErrors
- Number of Annex-D signaling protocol errors between the Cisco 90 Series Agent and the Frame Relay Switch. A signaling protocol error is declared whenever the Cisco 90 Series Agent receives a reply with incorrect format or sequence numbers from the frame r ...
- frxAgtChInactive
- Number of times the Cisco 90 Series Agent Annex-D signaling channel was declared inactive.
- frxAgtChStatus
- Current status of the Annex-D signaling channel between the Cisco 90 Series Agent and the Frame Relay Switch.
- frxDefaultEnable
- 1=Enable automatic loading of defaults (defined in this group) to the channel unit when the Download Configuration pushbutton on the channel unit faceplate is pushed. 2=Disable loading.
- frxDefaultTrap
- 1=Enable sending the frxDownloadTrap trap to the SNMP manager when the Download Configuration pushbutton on the channel unit faceplate is pushed. 2=Disable Trap
- frxDConfigSrc
- System default for frxConfigSrc - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. 1=Data rate and protocol set by Annex-D assignment rules. 2=Data rate and protocol set by the ...
- frxDMgtT391
- System Default for frxMgtT391 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how often (in seconds) the channel units send an Annex-D poll to the frame relay s ...
- frxDMgtT392
- System Default for frxMgtT392 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how long (in seconds) the channel unit will wait for a subscriber to send it an An ...
- frxDMgtN391
- System Default for frxMgtN391 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This controls how often the channel units send a full status inquiry poll to the frame relay swi ...
- frxDMgtN392
- System Default for frxMgtN392 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the ne ...
- frxDMgtN393
- System Default for frxMgtN393 - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the ne ...
- frxDPortSpeed
- System Default for frxPortSpeed - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the speed that the channel unit port runs at. 1=56kbps 2=64kbps 3=128kbps 4=144k ...
- frxDPortProtocol
- System Default for frxPortProtocol - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. 1=Port uses Frame Relay protocol 2=Port uses PPP protocol - do RFC-1973 encapsulation
- frxDCktCIR
- System Default for frxCktCIR - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the committed information rate (CIR) in bits per second. (Typical value 1536000/#ports)
- frxDCktBc
- System Default for frxCktBc - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the committed BurstSize (Bc) in bits. The time interval over which the burst is measured i ...
- frxDCktBe
- System Default for frxCktBe - used when the Download Configuration pushbutton on the channel unit faceplate is pushed and when frxDefaultEnable is set to 1. This is the excess BurstSize (Be) in bits. The time interval over which the excess burst is measur ...
- frxBankTable
- This Cisco 90 Series Bank Di-group Table contains channel bank level information for each of the channel bank di-groups in the system. A di-group is a T1 interface to the frame relay network. The table is indexed using the Cisco 90 Series channel bank dig ...
- frxBankEntry
- A specific entry in the Cisco 90 Series Bank Di-group Table. There is one entry for each channel bank di-group (T1) in the system. There are no entries for unused banks
- frxBankIndex
- Channel Bank Di-group Number. This index is used to address the various channel banks in the system. This number is the same as the DLCI number used to communicate with the bank at the Cisco 90 SNMP Agent. (note that this is NOT the same as the DLCI numbe ...
- frxBankType
- This is the type of channel bank and is for future use. D4 banks return a value of 1.
- frxChUTable
- This Cisco 90 Series Channel Unit Table contains channel unit level control and statistics for each of the Cisco 90 Series channel units in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit ...
- frxChUEntry
- A specific entry in the Cisco 90 Series Channel Unit Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots
- frxChUIndex
- Channel Unit Number. This index is used to address a specific channel unit in a bank. For D4 channel banks this number is the same as the physical slot number 1-24
- frxChUType
- Type of Cisco 90 Series channel unit installed.
- frxChUVersion
- Cisco 90 Series channel unit version number.
- frxSigProtocol
- This is the type of Local In-channel Signaling used when the subscriber is running frame relay protocol. It is provided for future use. Set to 1 for T1.617 Annex-D
- frxConfigSrc
- Source for configuring speed and protocol for each port. 1=Data rate and protocol set by DLCI assignment rules as reported by Annex-D. This option allows control of these basic parameters from the frame relay switch management station instead of the Cisc ...
- frxDLCIAdLen
- The number of bytes used for the DLCI address. For future use. 1=two octets.
- frxNetInOctets
- Total number of octets received by this channel unit from Frame Relay Switch (on the T1 interface) Only frames whose DLCI is addressed to a port on this channel unit are counted. Bad frames, Annex-D and SNMP frames are not counted. CRC bytes are not coun ...
- frxNetOutOctets
- Total number of octets transmitted to the Frame Relay Switch (on the T1 interface) by this channel unit. Annex-D and SNMP frames are not counted. CRC bytes are not counted
- frxNetBadFrames
- Total number of frames received on the network (T1) interface that are discarded by this channel unit. Possible reasons for discard are: Frame contained HDLC abort (7 or more ones in a row) Frame had a CRC error Frame had a non-integral number of bytes Fr ...
- frxNetHDLCEs
- Network Errored Seconds caused by HDLC aborts (7 or more ones in a row). Total number of seconds in which a frame with an HDLC abort is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this chan ...
- frxNetCRCEs
- Network Errored Seconds caused by CRC errors. Total number of seconds in which a frame with a CRC error is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channel unit are counted.
- frxNetLinkEs
- Network Errored Seconds caused by Non-integral Bytes. Total number of seconds in which a frame with a non-integral number of bytes is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this channe ...
- frxNetFrShEs
- Network Errored Seconds caused by Short Frames received. Total number of seconds in which a frame that is too short (less than 5 bytes) is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this c ...
- frxNetFrLgEs
- Network Errored Seconds caused by Long Frames received. Total number of seconds in which a frame that is too long (more than 8192 bytes) is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port on this ...
- frxNetPPPEs
- Errored seconds caused by bad RFC-1973 (PPP) header. Total number of seconds in which a frame with an invalid RFC-1973 (PPP) header is received by this channel unit on the network (T1) interface. Only frames whose DLCI is addressed to a port that is set t ...
- frxNetBufEs
- Errored Seconds caused by Buffer Overflow. Total number of seconds in which a frame received by this channel unit on the network (T1) interface was discarded due to insufficient buffer space. Only frames whose DLCI is addressed to a port on this channel u ...
- frxMgtTable
- This table monitors and controls the T1-617 Annex-D parameters used by the channel units. There is one table row for every channel unit in every bank. The table is indexed first using the Cisco 90 Series channel bank digroup number, then the channel unit ...
- frxMgtEntry
- A specific entry in the Cisco 90 Series Management Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots
- frxPortsInSvc
- Ports in service. The number of ports on a Cisco 90 Series channel unit that have one or more active PVCs, as determined by Annex-D.
- frxMgtT391
- This controls how often (in seconds) the channel unit sends an Annex-D poll to the frame relay switch. This is the Annex-D T391 parameter (Typical value 10)
- frxMgtT392
- This controls how long (in seconds) the channel unit will wait for a subscriber to send it an Annex-D poll before declaring a link error from the subscriber. This is the Annex-D T392 parameter (Typical value 15)
- frxMgtN391
- This controls how often (in polls) the channel unit sends a full status inquiry poll to the frame relay switch instead of a link integrity verification poll. This is the Annex-D N391 parameter (Typical value 6)
- frxMgtN392
- When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N392 parameter (Typical value 3)
- frxMgtN393
- When more than frxMgtN392 errors are detected in any frxMgtN393 monitored Annex-D events, the network is declared inactive. This is the Annex-D N393 parameter (Typical value 4)
- frxNetLinkErrors
- Number of signaling link reliability errors from network. A signaling reliability error is declared whenever the channel units did not receive a reply from the frame relay switch to an Annex-D link integrity poll or full status inquiry poll
- frxNetProtErrors
- Number of signaling protocol errors from network. A signaling protocol error is declared whenever the channel units receive a reply with incorrect format or sequence numbers from the frame relay switch in response to an Annex-D link integrity poll or full ...
- frxNetChInactive
- Number of times network Annex-D signaling channel was declared inactive.
- frxNetChStatus
- Current status of the Annex-D signaling channel on the network side of the channel bank.
- frxMgtPortTable
- This table monitors the T1-617 Annex-D link between the channel units and the subscribers. There is one table row for every port on every channel unit in every bank. The table is indexed first using the channel bank digroup number, then the channel unit n ...
- frxMgtPortEntry
- A specific entry in the Cisco 90 Series Management Port Table. There is one entry for each port on each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots.
- frxPortIndex
- Which subscriber port on the channel unit is addressed. Ports are numbered from 0 to 3. Some channel unit types have less than 4 ports.
- frxPortLinkErrors
- Number of signaling link reliability errors from subscriber port. A signaling reliability error is declared whenever the channel units did not receive an Annex-D link integrity poll or full status inquiry poll from the subscriber port within the required ...
- frxPortProtErrors
- Number of signaling protocol errors from subscriber port. A signaling protocol error is declared whenever the channel units receive an Annex-D link integrity poll or full status inquiry poll with incorrect format or sequence numbers from the subscriber po ...
- frxPortChInactive
- Number of times the subscriber port Annex-D signaling channel was declared inactive
- frxPortTable
- This Cisco 90 Series Port Table contains per-port control and statistics for each of the subscriber ports in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then by the channel unit number (1 to 24), and final ...
- frxPortEntry
- A specific entry in the Cisco 90 Series Port Table. There is one entry for each port on each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots.
- frxPortSpeed
- This is the speed that the channel unit port runs at. 1=56kbps 2=64kbps 3=128kbps 4=144kbps This parameter can only be changed if frxConfigSrc is set to SNMP.
- frxPortProtocol
- This parameter controls what protocol the channel unit should expect the subscriber to send on the port. 1=Port uses Frame Relay protocol - no encapsulation 2=Port uses PPP protocol - do RFC-1973 encapsulation This parameter can only be changed if frxConf ...
- frxDSLStatus
- This is the status of the DSL loop to the subscriber. 1=Loop is down. 2=Frx card has achieved physical layer activation with the first BRITE card or the NT1 if there are no BRITE cards. 3=Link is up but Annex-D is still inactive. The ACT bit has been exc ...
- frxPVCAssigned
- Number of PVCs assigned to Subscriber Port as determined by Annex-D
- frxLastChange
- Time since DSL went in sync or lost sync in 0.01 second increments.
- frxBrite
- Number of BRITE cards downstream. BRITE cards are used to extend the loop over subscriber loop carrier systems and are detected via a background polling operation.
- frxDSLInOctets
- Number of octets received from the subscriber DSL Does not include Annex-D octets
- frxDSLOutOctets
- Number of octets transmitted to the subscriber DSL. Does not include Annex-D octets
- frxT1InOctets
- Number of octets received from the network directed at this subscriber port
- frxT1OutOctets
- Number of octets transmitted to the network from this subscriber port
- frxDSLBadFrames
- Total number of frames received from this subscriber port that were discarded. Possible reasons for discard are: Frame contained HDLC abort (7 or more ones in a row) Frame had a CRC error Frame had a non-integral number of bytes Frame was too short (less ...
- frxDSLHDLCEs
- Subscriber port Errored Seconds caused by HDLC aborts (7 or more ones in a row). Total number of seconds in which a frame with an HDLC abort is received from this port.
- frxDSLCRCEs
- Subscriber port Errored Seconds caused by CRC errors. Total number of seconds in which a frame with a CRC error is received from this port.
- frxDSLLinkEs
- Subscriber port Errored Seconds caused by Non-integral Bytes. Total number of seconds in which a frame with a non-integral number of bytes is received from this port.
- frxDSLFrShEs
- Subscriber port Errored Seconds caused by Short Frames. received Total number of seconds in which a frame that is too short (less than 5 bytes) is received from this port.
- frxDSLFrLgEs
- Subscriber port Errored Seconds caused by Long Frames received. Total number of seconds in which a frame that is too long (more than 8192 bytes) is received from this port.
- frxDSLDLCIEs
- Subscriber port Errored Seconds caused by illegal DLCI. Total number of seconds in which a frame that has a DLCI other than 16 to 23 (or 0) is received from this port.
- frxTxBuf
- Number of octets in the transmit buffer for this subscriber port. This data is waiting to be sent to the network (T1).
- frxRxBuf
- Number of octets in the receive buffer for this subscriber port. This data is from the network (T1) and is waiting to be sent to the subscriber port.
- frxPortNetEs
- Total number of seconds in which a frame received from the network (T1) and targeted at this subscriber port was discarded.
- frxCircuitTable
- This Cisco 90 Series Circuit Table contains per-virtual-circuit control and statistics for each of the permanent virtual circuits in the system. The table is indexed first using the Cisco 90 Series channel bank digroup number, then by the channel unit num ...
- frxCircuitEntry
- A specific entry in the Cisco 90 Series Circuit Table. There is one entry for each permanent virtual circuit in the system. There are no entries for unused banks or empty channel unit slots.
- frxPvcIndex
- This index is the subscriber loop DLCI number of the permanent virtual circuit. It ranges from 16 to 23. The corresponding network side DLCI must be assigned in the frame relay switch and communicated to the Cisco 90 Series channel units via the Annex-D p ...
- frxCktCIR
- This is the committed information rate (CIR) in bits per second for the addressed permanent virtual circuit. (Typical value 1536000/#ports).
- frxCktBc
- This is the Committed Burst Size (Bc) in bits for the addressed permanent virtual circuit. The time interval over which the burst is measured is Bc/CIR. (Typically set to same number as frxCktCIR).
- frxCktBe
- This is the Excess Burst Size (Be) in bits for the addressed permanent virtual circuit. The time interval over which the excess burst is measured is Be/CIR. (Typical value 1536000).
- frxFarEndOpStat
- This is the status of the far end of the frame relay permanent virtual circuit (through the frame relay network) as determined by Annex-D. 1=active 2=inactive
- frxCktInOctets
- The number of input octets from the subscriber port on the addressed permanent virtual circuit. These octets are destined for the network (T1).
- frxCktOutOctets
- The number of output octets to the subscriber port on the addressed permanent virtual circuit. These octets were received from the network (T1).
- frxCktInFrames
- The number of input frames from the subscriber port on the addressed permanent virtual circuit. These frames are destined for the network (T1).
- frxCktOutFrames
- The number of output frames to the subscriber port on the addressed permanent virtual circuit. These frames were received from the network (T1).
- frxCktDiscards
- The number of input frames from the subscriber port on the addressed permanent virtual circuit that were discarded due to congestion (lack of buffer space or congestion control.
- frxUEocTable
- This Cisco 90 Series Embedded Operations Channel Table is used to diagnose and sectionalize problems with the subscriber loop. It contains one entry for each of the Cisco 90 Series channel units in the system. The table is indexed first using the Cisco 9 ...
- frxUEocEntry
- A specific entry in the Cisco 90 Series Embedded Operations Channel Table. There is one entry for each Cisco 90 Series channel unit in the system. There are no entries for unused banks or empty channel unit slots
- frxTestPort
- This parameter indicates which subscriber port on the channel unit to test. It has no effect until frxStartTest is set to start the test. Only one port on a given channel unit may be tested at a time.
- frxTestType
- This parameter indicates the type of test to perform. It has no effect until frxStartTest is set to start the test. 1=Set up a loopback and run a PN-2047 Bit Error Rate Test. 2=Run a (straightaway) PN-2047 Bit Error Rate Test. This test assumes a loopbac ...
- frxLoopLoc
- This parameter indicates the location of the loopback or the card that will send corrupt CRC. It has no effect until frxStartTest is set to start the test. It has no effect for a BertOnly test. 7=Local Cisco 90 Series card 8=NT1 at customer premise 1 to ...
- frxLoopCh
- This parameter indicates which channels to use for the loopbackOnly and localLoopAllPorts test. It has no effect until frxStartTest is set to start the test. Note that the loopbackAndBert test always loops all channels back. 1=B1 channel 2=B2 channel ...
- frxStartTest
- This parameter is used to start and stop the test. frxTestPort, frxTestType, frxLoopLoc, and frxLoopCh should be set up prior to starting the test. 1=stop test. 2=start test.
- frxBertRst
- This parameter may be used during a LoopbackAndBert test or a BertOnly test to reset the frxBertBE counter. It must be returned to the normal posiion to allow errors to be counted. 1=normal. 2=Reset BERT counter.
- frxBertBE
- BERT test block errors
- frxBertTestTime
- BERT test time in 0.01 second increments
- frxTestInProg
- Test in progress (1); Normal operation (2)
- frxUThrTable
- This table contains the U-interface Performance Monitoring Thresholds and Alarms for each of the subscriber loops in the system and for any BRITE cards extending those loops (e.g. using Subscriber Loop Carrier systems) The table is indexed first using th ...
- frxUThrEntry
- A specific entry in the U-interface Performance Monitoring Threshold table. There is one entry for each port on each Cisco 90 Series channel unit in the system and one entry for each BRITE card extending those ports. There are no entries for unused bank ...
- frxPAddrIndex
- This is the physical location where the performance monitoring takes place. It may be set to localFrx(7) to access and control PM values local to the Cisco 90 Series channel unit. If there are BRITE cards in the subscriber loop between the Cisco 90 Serie ...
- frxChEsTh
- Current Hour Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxT ...
- frxCdEsTh
- Current Day Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in the frxTh ...
- frxChSesTh
- Current Hour Severely Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in ...
- frxCdSesTh
- Current Day Severely Errored Seconds threshold. This threshold is used for both the transmit and receive directions. When errors are detected that exceed this threshold and the corresponding bit in the frxAlertMask register is 0, the corresponding bit in ...
- frxAlertMask
- 8-bit Alert Mask register. One bit for each threshold in both directions. When set to 1, the corresponding threshold crossing is ignored. When set to 0, the corresponding threshold crossing is indicated in frxThCond and may cause a trap to be sent depend ...
- frxThCond
- 8-bit Threshold Condition register. One bit for each threshold in both directions. Set to 1 if the threshold is exceeded and the corresponding bit in the frxAlertMask register is set to 0. Only set to 0 by the SNMP manager. 1 Current Day Severely Errore ...
- frxUPerfTable
- This table contains the U-interface Performance Monitoring Statistics for each of the subscriber loops in the system and for any BRITE cards extending those loops (e.g. using Subscriber Loop Carrier systems) The table is indexed first using the Cisco 90 ...
- frxUPerfEntry
- A specific entry in the U-interface Performance Monitoring Statistics table. There is one entry for each port on each Cisco 90 Series channel unit in the system and one entry for each BRITE card extending those ports. There are no entries for unused ban ...
- frxResetPM
- Reset all of the performance monitoring statistics on the specified Cisco 90 Series channel unit or BRITE card. 1=Normal. 2=Reset. There is no need to set this register back to Normal after doing a reset.
- frxPMtype
- Determines if the Cisco 90 Series channel unit or the downstream BRITE cards is doing segmented or path performance monitoring as specified in Bellcore document TR-NWT-000397. Only segmented performance monitoring should be used. In segmented PM, CRC er ...
- frxChEsTx
- Current Hour Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV erro ...
- frxChEsRx
- Current Hour Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors ...
- frxPhEsTx
- Previous Hour Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV err ...
- frxPhEsRx
- Previous Hour Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH2EsTx
- Errored Seconds 2 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH2EsRx
- Errored Seconds 2 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxH3EsTx
- Errored Seconds 3 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH3EsRx
- Errored Seconds 3 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxH4EsTx
- Errored Seconds 4 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH4EsRx
- Errored Seconds 4 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxH5EsTx
- Errored Seconds 5 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH5EsRx
- Errored Seconds 5 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxH6EsTx
- Errored Seconds 6 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH6EsRx
- Errored Seconds 6 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxH7EsTx
- Errored Seconds 7 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH7EsRx
- Errored Seconds 7 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxH8EsTx
- Errored Seconds 8 hours ago - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxH8EsRx
- Errored Seconds 8 hours ago - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxCdEsTx
- Current Day Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV error ...
- frxCdEsRx
- Current Day Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors) ...
- frxPdEsTx
- Previous Day Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV erro ...
- frxPdEsRx
- Previous Day Errored Seconds - Receive direction. Receive is data from the customer towards the network. Errored Seconds are seconds in which one or more block errors occur. These errors are measured at the physical link level (e.g. DSL CRC or BPV errors ...
- frxChSesTx
- Current Hour Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. ...
- frxChSesRx
- Current Hour Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. D ...
- frxPhSesTx
- Previous Hour Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g ...
- frxPhSesRx
- Previous Hour Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. ...
- frxCdSesTx
- Current Day Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. ...
- frxCdSesRx
- Current Day Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. DS ...
- frxPdSesTx
- Previous Day Severely Errored Seconds - Transmit direction. Transmit is data from the network towards the customer. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. ...
- frxPdSesRx
- Previous Day Severely Errored Seconds - Receive direction. Receive is data from the customer towards the network. Severely Errored Seconds are seconds in which three or more block errors occur. These errors are measured at the physical link level (e.g. D ...
- frxChBeTx
- Current Hour Block Errors - Transmit direction. Transmit is data from the network towards the customer. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame ...
- frxChBeRx
- Current Hour Block Errors - Receive direction. Receive is data from the customer towards the network. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame re ...
- frxPhBeTx
- Previous Hour Block Errors - Transmit direction. Transmit is data from the network towards the customer. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame ...
- frxPhBeRx
- Previous Hour Block Errors - Receive direction. Receive is data from the customer towards the network. Block errors are 12 millisecond time periods in which a physical link level (e.g. DSL CRC or BPV) error occurs. These errors are not the same as frame r ...
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.