The CISCO-ENTITY-FRU-CONTROL-MIB is used to monitor and configure operational status of Field Replaceable Units (FRUs) and other managable physical entities of the system listed in the Entity-MIB (RFC 2737) entPhysicalTable. FRUs include assemblies such as power supplies, fans, processor modules, interface modules, etc.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-ENTITY-FRU-CONTROL-MIB

cefcFRUPowerSupplyGroupTable
This table lists the redundancy mode and the operational status of the power supply groups in the system.
cefcFRUPowerSupplyGroupEntry
An cefcFRUPowerSupplyGroupTable entry lists the desired redundancy mode, the units of the power outputs and the available and drawn current for the power supply group. Entries are created by the agent when a power supply group is added to the entPhysicalT ...
cefcPowerRedundancyMode
The administratively desired power supply redundancy mode.
cefcPowerUnits
The units of primary supply to interpret cefcTotalAvailableCurrent and cefcTotalDrawnCurrent as power. For example, one 1000-watt power supply could deliver 100 amperes at 10 volts DC. So the value of cefcPowerUnits would be 'at 10 volts DC'. cefcPowerUn ...
cefcTotalAvailableCurrent
Total current available for FRU usage.
cefcTotalDrawnCurrent
Total current drawn by powered-on FRUs.
cefcPowerRedundancyOperMode
The power supply redundancy operational mode.
cefcPowerNonRedundantReason
This object has the value of notApplicable(1) when cefcPowerRedundancyOperMode of the instance does not have the value of nonRedundant(4). The other values explain the reason why cefcPowerRedundancyOperMode is nonRedundant(4), e.g. unknown(2) ...
cefcTotalDrawnInlineCurrent
Total inline current drawn for inline operation.
cefcFRUPowerStatusTable
This table lists the power-related administrative status and operational status of the manageable components in the system.
cefcFRUPowerStatusEntry
An cefcFRUPowerStatusTable entry lists the desired administrative status, the operational status of the power manageable component, and the current required by the component for operation. Entries are created by the agent at system power-up or the inserti ...
cefcFRUPowerAdminStatus
Administratively desired FRU power state.
cefcFRUPowerOperStatus
Operational FRU power state.
cefcFRUCurrent
Current supplied by the FRU (positive values) or current required to operate the FRU (negative values).
cefcFRUPowerCapability
This object indicates the set of supported power capabilities of the FRU. realTimeCurrent(0) - cefcFRURealTimeCurrent is supported by the FRU.
cefcFRURealTimeCurrent
This object indicates the realtime value of current supplied by the FRU (positive values) or the realtime value of current drawn by the FRU (negative values).
cefcMaxDefaultInLinePower
The system will provide power to the device connecting to the FRU if the device needs power, like an IP Phone. We call the providing power inline power. This MIB object controls the maximum default inline power for the device connecting to the FRU in the ...
cefcFRUPowerSupplyValueTable
This table lists the power capacity of a power FRU in the system if it provides variable power. Power supplies usually provide either system or inline power. They cannot be controlled by software to dictate how they distribute power. We can also have what ...
cefcFRUPowerSupplyValueEntry
An cefcFRUPowerSupplyValueTable entry lists the current provided by the FRU for operation. Entries are created by the agent at system power-up or FRU insertion. Entries are deleted by the agent at FRU removal. Only power supply FRUs are listed in the tab ...
cefcFRUTotalSystemCurrent
Total current that could be supplied by the FRU (positive values) for system operations.
cefcFRUDrawnSystemCurrent
Amount of current drawn by the FRU's in the system towards system operations from this FRU
cefcFRUTotalInlineCurrent
Total current supplied by the FRU (positive values) for inline operations.
cefcFRUDrawnInlineCurrent
Amount of current that is being drawn from this FRU for inline operation.
cefcMaxDefaultHighInLinePower
The system will provide power to the device connecting to the FRU if the device needs power, like an IP Phone. We call the providing power inline power. This MIB object controls the maximum default inline power for the device connecting to the FRU in the ...
cefcModuleTable
A cefcModuleTable entry lists the operational and administrative status information for ENTITY-MIB entPhysicalTable entries for manageable components of type PhysicalClass module(9).
cefcModuleEntry
A cefcModuleStatusTable entry lists the operational and administrative status information for ENTITY-MIB entPhysicalTable entries for manageable components of type PhysicalClass module(9). Entries are created by the agent at the system power-up or module ...
cefcModuleAdminStatus
This object provides administrative control of the module.
cefcModuleOperStatus
This object shows the module's operational state.
cefcModuleResetReason
This object identifies the reason for the last reset performed on the module.
cefcModuleStatusLastChangeTime
The value of sysUpTime at the time the cefcModuleOperStatus is changed.
cefcModuleLastClearConfigTime
The value of sysUpTime when the configuration was most recently cleared.
cefcModuleResetReasonDescription
A description qualifying the module reset reason specified in cefcModuleResetReason. Examples: command xyz missing task switch over watchdog timeout etc. cefcModuleResetReasonDescription is for display purposes only. NMS applications must not parse.
cefcModuleStateChangeReasonDescr
This object displays human-readable textual string which describes the cause of the last state change of the module. This object contains zero length string if no meaningful reason could be provided. Examples: 'Invalid software version' 'Software download ...
cefcModuleUpTime
This object provides the up time for the module since it was last re-initialized. This object is not persistent; if a module reset, restart, power off, the up time starts from zero.
cefcIntelliModuleTable
This table sparsely augments the cefcModuleTable (i.e., every row in this table corresponds to a row in the cefcModuleTable but not necessarily vice-versa). A cefcIntelliModuleTable entry lists the information specific to intelligent modules which cannot ...
cefcIntelliModuleEntry
A cefcIntelliModuleTable entry lists the information specific to an intelligent module which cannot be provided by this module's corresponding instance in the cefcModuleTable. Only an intelligent module with Internet address configured has its entry here. ...
cefcIntelliModuleIPAddrType
The type of Internet address by which the intelligent module is reachable.
cefcIntelliModuleIPAddr
The Internet address configured for the intelligent module. The type of this address is determined by the value of the object cefcIntelliModuleIPAddrType.
cefcModuleLocalSwitchingTable
This table sparsely augments the cefcModuleTable (i.e., every row in this table corresponds to a row in the cefcModuleTable but not necessarily vice-versa). A cefcModuleLocalSwitchingTable entry lists the information specific to local switching capable mo ...
cefcModuleLocalSwitchingEntry
A cefcModuleLocalSwitchingTable entry lists the information specific to a local switching capable module which cannot be provided by this module's corresponding instance in the cefcModuleTable. Only a module which is capable of local switching has its ent ...
cefcModuleLocalSwitchingMode
This object specifies the mode of local switching. enabled(1) - local switching is enabled. disabled(2) - local switching is disabled.
cefcFanTrayStatusTable
This table contains the operational status information for all ENTITY-MIB entPhysicalTable entries which have an entPhysicalClass of 'fan'; specifically, all entPhysicalTable entries which represent either: one physical fan, or a single physical 'fan tray ...
cefcFanTrayStatusEntry
An cefcFanTrayStatusTable entry lists the operational status information for the ENTITY-MIB entPhysicalTable entry which is identified by the value of entPhysicalIndex. The value of entPhysicalClass for the identified entry will be 'fan', and the represen ...
cefcFanTrayOperStatus
The operational state of the fan or fan tray. unknown(1) - unknown. up(2) - powered on. down(3) - powered down. warning(4) - partial failure, needs replacement as soon as possible.
cefcPhysicalTable
This table contains one row per physical entity.
cefcPhysicalEntry
Information about a particular physical entity.
cefcPhysicalStatus
The status of this physical entity. other(1) - the status is not any of the listed below. supported(2) - this entity is supported. unsupported(3) - this entity is unsupported. incompatible(4) - this entity is incompatible. It would be unsupported(3), if t ...
cefcPowerSupplyInputTable
This table contains the power input information for all the power supplies that have entPhysicalTable entries with 'powerSupply' in the entPhysicalClass. The entries are created by the agent at the system power-up or power supply insertion. Entries are de ...
cefcPowerSupplyInputEntry
An entry containing power input management information applicable to a particular power supply and input.
cefcPowerSupplyInputIndex
A unique value, greater than zero, for each input on a power supply.
cefcPowerSupplyInputType
The type of an input power detected on the power supply. unknown(1): No input power is detected. acLow(2): Lower rating AC input power is detected. acHigh(3): Higher rating AC input power is detected. dcLow(4): Lower rating DC input power is detected. dcH ...
cefcPowerSupplyOutputTable
This table contains a list of possible output mode for the power supplies, whose ENTITY-MIB entPhysicalTable entries have an entPhysicalClass of 'powerSupply'. It also indicate which mode is the operational mode within the system.
cefcPowerSupplyOutputEntry
A cefcPowerSupplyOutputTable entry lists the power output capacity and its operational status for manageable components of type PhysicalClass 'powerSupply'. Entries are created by the agent at the system power-up or power supply insertion. Entries are del ...
cefcPSOutputModeIndex
A unique value, greater than zero, for each possible output mode on a power supply.
cefcPSOutputModeCurrent
The output capacity of the power supply.
cefcPSOutputModeInOperation
A value of 'true' indicates that this mode is the operational mode of the power supply output capacity. A value of 'false' indicates that this mode is not the operational mode of the power supply output capacity. For a given power supply's entPhysicalInde ...
cefcChassisCoolingTable
This table contains the cooling capacity information of the chassis whose ENTITY-MIB entPhysicalTable entries have an entPhysicalClass of 'chassis'.
cefcChassisCoolingEntry
A cefcChassisCoolingEntry lists the maximum cooling capacity that could be provided for one slot on the manageable components of type PhysicalClass 'chassis'. Entries are created by the agent if the corresponding entry is created in ENTITY-MIB entPhysical ...
cefcChassisPerSlotCoolingCap
The maximum cooling capacity that could be provided for any slot in this chassis. The default unit of the cooling capacity is 'cfm', if cefcChassisPerSlotCoolingUnit is not supported.
cefcChassisPerSlotCoolingUnit
The unit of the maximum cooling capacity for any slot in this chassis.
cefcFanCoolingTable
This table contains the cooling capacity information of the fans whose ENTITY-MIB entPhysicalTable entries have an entPhysicalClass of 'fan'.
cefcFanCoolingEntry
A cefcFanCoolingEntry lists the cooling capacity that is provided by the manageable components of type PhysicalClass 'fan'. Entries are created by the agent if the corresponding entry is created in ENTITY-MIB entPhysicalTable. Entries are deleted by the a ...
cefcFanCoolingCapacity
The cooling capacity that is provided by this fan. The default unit of the fan cooling capacity is 'cfm', if cefcFanCoolingCapacityUnit is not supported.
cefcFanCoolingCapacityUnit
The unit of the fan cooling capacity.
cefcModuleCoolingTable
This table contains the cooling requirement for all the manageable components of type entPhysicalClass 'module'.
cefcModuleCoolingEntry
A cefcModuleCoolingEntry lists the cooling requirement for a manageable components of type entPhysicalClass 'module'. Entries are created by the agent at the system power-up or module insertion. Entries are deleted by the agent upon module removal.
cefcModuleCooling
The cooling requirement of the module and its daughter cards. The default unit of the module cooling requirement is 'cfm', if cefcModuleCoolingUnit is not supported.
cefcModuleCoolingUnit
The unit of the cooling requirement of the module and its daughter cards.
cefcFanCoolingCapTable
This table contains a list of the possible cooling capacity modes and properties of the fans, whose ENTITY-MIB entPhysicalTable entries have an entPhysicalClass of 'fan'.
cefcFanCoolingCapEntry
A cefcFanCoolingCapacityEntry lists the cooling capacity mode of a manageable components of type entPhysicalClass 'fan'. It also lists the corresponding cooling capacity provided and the power consumed by the fan on this mode. Entries are created by the a ...
cefcFanCoolingCapIndex
An arbitrary value that uniquely identifies a cooling capacity mode for a fan.
cefcFanCoolingCapModeDescr
A textual description of the cooling capacity mode of the fan.
cefcFanCoolingCapCapacity
The cooling capacity that could be provided when the fan is operating in this mode. The default unit of the cooling capacity is 'cfm', if cefcFanCoolingCapCapacityUnit is not supported.
cefcFanCoolingCapCurrent
The power consumption of the fan when operating in in this mode.
cefcFanCoolingCapCapacityUnit
The unit of the fan cooling capacity when operating in this mode.
cefcConnectorRatingTable
This table contains the connector power ratings of FRUs. Only components with power connector rating management are listed in this table.
cefcConnectorRatingEntry
A cefcConnectorRatingEntry lists the power connector rating information of a component in the system. An entry or entries are created by the agent when an physical entity with connector rating management is added to the ENTITY-MIB entPhysicalTable. An ent ...
cefcConnectorRating
The maximum power that the component's connector can withdraw.
cefcModulePowerConsumptionTable
This table contains the total power consumption information for modules whose ENTITY-MIB entPhysicalTable entries have an entPhysicalClass of 'module'.
cefcModulePowerConsumptionEntry
A cefcModulePowerConsumptionEntry lists the total power consumption of a manageable components of type entPhysicalClass 'module'. Entries are created by the agent at the system power-up or module insertion. Entries are deleted by the agent upon module rem ...
cefcModulePowerConsumption
The combined power consumption to operate the module and its submodule(s) and inline-power device(s).
cefcMIBEnableStatusNotification
This variable indicates whether the system produces the following notifications: cefcModuleStatusChange, cefcPowerStatusChange, cefcFRUInserted, cefcFRURemoved, cefcUnrecognizedFRU and cefcFanTrayStatusChange. A false value will prevent these notification ...
cefcEnablePSOutputChangeNotif
This variable indicates whether the system produces the cefcPowerSupplyOutputChange notifications when the output capacity of a power supply has changed. A false value will prevent this notification to generated.
cefcMIBPowerModeGroup
The collection of objects which are used to configure and monitor power-control for FRUs.
cefcMIBPowerFRUControlGroup
The collection of objects which are used to configure and monitor power-control for FRUs.
cefcMIBModuleGroup
The collection of objects which are used to get the operational state and redundancy state of the modules
cefcMIBInLinePowerControlGroup
The collection of objects which are used to configure and monitor inline power control for FRUs.
cefcMIBNotificationEnablesGroup
The collection of objects which are used to enable notification.
cefcModuleGroupRev1
The collection of objects which are used to get the operational state and redundancy state of the modules
cefcMIBPowerFRUValueGroup
The collection of objects which are used to retrieve the total and used capacity of a power supply for both system and inline power.
cefcMIBFanTrayStatusGroup
The collection of objects which show information of the status of Fan Tray FRUs.
cefcMIBPhysicalGroup
The collection of objects which show information of the Physical Entity.
cefcMIBPowerOperModeGroup
The collection of objects which are used to monitor the device's power supply operational redundancy mode.
cefcMIBInLinePowerControlGroupRev1
The collection of objects which are used to configure and monitor inline power control for FRUs.
cefcModuleExtGroup
The collection of objects which are used to get the state change reason and up time of the modules.
cefcIntelliModuleGroup
The collection of objects which are used to get the information specific to intelligent modules.
cefcPowerCapacityGroup
The collection of objects which are used to get the power capacity information
cefcCoolingGroup
The collection of objects which are used to get the cooling capacity information.
cefcConnectorRatingGroup
The collection of objects which are used to get the power connector rating and module power total consumption information.
cefcMIBNotificationEnablesGroup2
The collection of objects which are used to enable additional group of notifications.
cefcMIBInLinePowerCurrentGroup
The collection of objects which are used to monitor inline power usage for FRUs.
cefcMIBPowerRedundancyInfoGroup
The collection of objects provide additional information about the device's power supply redundancy.
cefcFanCoolingCapGroup
The collection of objects provide the cooling capacity modes and properties of the fans.
cefcMIBModuleLocalSwitchingGroup
The collection of objects which show information of the local switching status of modules.
cefcFRUPowerRealTimeStatusGroup
The collection of objects provide the power-related realtime information of the manageable entities.
cefcFRUPowerCapabilityGroup
The collection of objects provide the power-related capability information of the manageable entities.
cefcFRUCoolingUnitGroup
The collection of objects provide the cooling unit information of the manageable entities.
cefcFRUFanCoolingUnitGroup
The collection of objects provide the cooling unit information of the manageable fan entities.
cefcCoolingGroup2
The collection of objects which are used to get the cooling capacity or requirement information.
cefcFanCoolingGroup
The collection of objects provide the cooling capacity modes and properties of the fans.