CISCO-FICON-MIB

CISCO-FICON-MIB Download

MIBs list

This is the FICON (FIber CONnection) MIB module. FICON is an IBM standard of transport mechanism for communication between the mainframes and devices and is a major consideration for enterprise data centers. The Cisco MDS Storage Area Network (SAN) switches provide the functionality of a FICON Director to the customers.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-FICON-MIB

cficonDefaultPortBlock
This object indicates the default state which whether to prohibit traffic or allow traffic among all External Ports of a new FICON VSAN. If 'true' the default state is prohibit all traffic, else the default state is allow all traffic. The default values o ...
cficonPortSwapTable
A table to issue the port swap command. In FICON, lots of configuration in the host is associated with a port-address. If the FICON port connecting the host to the switch has some problem and the user wants to connect the host to a different port in the s ...
cficonPortSwapEntry
A cficonPortSwapTable entry. A management station wishing to create an entry should first generate a pseudo-random serial number to be used as the index to this sparse table. The station should then create the associated instance of the row status object ...
cficonPortSwapIndex
An arbitrary index for the swap command.
cficonSwapPortNumberFirst
The first port number that needs to be swapped .
cficonSwapPortNumberSecond
The second port number that needs to be swapped.
cficonSwapPortEntryStatus
If this object is set to 'createAndGo(4)' then the port configurations of the ports specified by objects cficonSwapPortNumberFirst and cficonSwapPortNumberSecond will be swapped.
cficonVsanTable
A table containing the objects to manage FICON functionality in a VSAN.
cficonVsanEntry
A cficonVsanTable entry. Each entry, identified by vsanIndex, provides the objects to manage FICON functionality in this VSAN, identified by vsanIndex. To create a vsan, only the cficonVsanEntryStatus needs to be set in the PDU. A vsan will be created wit ...
cficonVsanHostControlSwOffline
The object specifying whether the host can put the VSAN offline. If 'true' it allows the host to put the VSAN offline, else it cannot.
cficonVsanHostControlClkAlrtMode
The object indicates whether director clock alert mode is enabled or disabled. If 'true', the mode is enabled, else it is disabled.
cficonVsanSnmpControl
The object indicates whether network management system is allowed to alter FICON director connectivity parameters. If 'true', the network management system is allowed to alter FICON director connectivity parameters, else, it cannot.
cficonVsanAutoSavePortAddrCfg
The object indicating whether the configuration will be saved in the configuration file for this VSAN. When an operator modifies a configuration, the running configuration is modified. If this object is 'true', then the configuration is saved in the confi ...
cficonVsanEnableCup
The object indicating Control Unit Port (CUP) is enabled. If 'true', CUP is enabled, else it is disabled.
cficonVsanCodePage
The EBCDIC Code page used for the exchange of information with the host in this VSAN.
cficonVsanCharSet
The Character Set used for the exchange of of information with the host in this VSAN. DEFVAL { charSet697 } ::= { cficonVsanEntry 8 } SYNTAX Integer32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION A counter that is incre ...
cficonVsanUserAlertMode
The object indicating whether director user alert mode is enabled or disabled. If 'true', the mode is enabled. else it is disabled.
cficonVsanDeviceAllegience
The object indicating whether CUP is in a allegiance state. If it is in allegiance state with a channel, it cannot accept any commands from any logical paths. A CUP goes in an allegiance state when it accepts command from a channel and forms 'an allegianc ...
cficonVsanTime
The system time in the VSAN. This could be set either by the host or be the default global time in the FICON Director. The default global time is the local time in the FICON Director. The format is as follows - Wed Nov 5 18:53:52.172485 2003 ::= { cficon ...
cficonVsanCupName
The name of CUP.
cficonSetHostTimeControl
The object indicating whether VSAN time can be set by the host. If 'true', the host can set the time, else it can not.
cficonVsanClearAllegience
The object used to clear a CUP allegiance. If this object is set with value, 'clear(1)' the CUP goes in a 'non-allegiance' or 'unlocked' mode as described in the description of cficonVsanDeviceAllegience object above.
cficonVsanEntryStatus
The status of this table entry.
cficonVsanFiconState
The object used to control the state of the ports belonging to a vsan in the context of the FICON functionality. If this object is set to 'offline(1)' all the ports belonging to the vsan, specified by the vsanIndex are put in the suspended state. If this ...
cficonVsanSerialNum
The serial number of the FICON director.
cficonPortTable
A table listing the port information as stored in the configuration file.
cficonPortEntry
A cficonPortTable entry. Each entry provides the information about a port, identified by cficonPortAddr, in the configuration file, identified by cficonPortFilename, on this VSAN, identified by vsanIndex.
cficonPortAddr
The Port Address of this port.
cficonPortBlock
The object indicates whether to block or unblock this port. This is one of the port-connectivity parameters. If 'true' this port is blocked, else it is unblocked.
cficonPortName
The name of this port.
cficonProhibitPortNumbers
The list of ports that will be prohibited from communication. Each octet within the value of an object of this type, specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Wi ...
cficonPortRunCfgTable
A table listing the port information as stored in the running configuration. Each port is identified by the port address in the context of its vsan Index.
cficonPortRunCfgEntry
A cficonPortRunCfgTable entry. Each entry provides the information about a port (identified by cficonPortAddr), on this VSAN (identified by vsanIndex), for the running configuration.
cficonPortRunCfgAddr
The address of this port.
cficonPortRunCfgBlock
The object indicating whether to block or unblock this port. If 'true' this port is blocked, else it is unblocked.
cficonPortRunCfgName
The port name of this port.
cficonRunCfgProhibitPrtNums
The list of ports that will be prohibited. Each octet within the value of an object of this type specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the ...
cficonRunCfgTypeNumber
The type number for this FICON Director.
cficonRunCfgModelNumber
The model number for this FICON Director. It is in the form of ASCII characters.
cficonRunCfgManufacturer
The name of the the company that manufactured this FICON Director. ::= { cficonPortRunCfgEntry 7 } SYNTAX DisplayString (SIZE (1..16)) MAX-ACCESS read-only STATUS current DESCRIPTION The plant code that identifies the plant of ...
cficonRunCfgUnitType
The peer type of the port that this port is communicating. channel - Host controlUnit - Disk fabric - Another SAN switch
cficonRunCfgPortId
This is the identifier of the peer port. If the peer port is channel, as described by the instance of cficonRunCfgUnitType, then cficonRunCfgPortId will be the CHPID (Channel Path Identifier) of the channel path that contains this peer port. If the peer p ...
cficonRunCfgStatus
This object specifies the status of the row, whether some specific columns in this row are valid, invalid or old. These specific columns are - cficonRunCfgProhibitPrtNums, cficonRunCfgTypeNumber, cficonRunCfgModelNumber, cficonRunCfgManufacturer, cficonRu ...
cficonCfgFileEntry
A cficonCfgFileTable entry. Each entry provides the configuration file for a vsan (identified by vsanIndex) and a file (identified by cficonCfgFilename). Each entry lists the file status, the time the file was last updated etc. The cficonCfgFileRowStatus ...
cficonCfgFileDescr
The description of the configuration file.
cficonCfgFileStatus
The status of filename containing these ports. Network Management station must check this object before it can read the contents of the configuration file. If it is 'locked', it means that the host or the CLI or the network management station is in the pr ...
cficonCfgFileLastUpdated
The time this file was last updated. The format is as follows - Wed Nov 5 18:53:52.172485 2003 ::= { cficonCfgFileEntry 4 } SYNTAX INTEGER { apply(1), noOp(2), open(3), close(4) } MAX-ACCESS read-create STATUS current DESCRIPTION The ...
cficonCfgFileRowStatus
The rowStatus of this row.
cficonCfgFileCmdStatus
The object to describe the status of the last 'apply' command. success - The last apply command was successful. inProgress - The last apply command is still in the process of execution. failed - The last apply command failed. notApplicable ...
cficonCfgFileCmdErrorString
The string describing the reason the the last 'apply' command failed. This string needs to be polled only in the case when the value of the cficonCfgFileCmdStatus is 'failed'. ::= { cficonCfgFileEntry 8 } -- -- Port number to ifIndex association table -- ...
cficonPortNumIfEntry
A cficonPortNumIfTable entry. Each entry provides a mapping between the port number and its interface index.
cficonPortNumber
The port number of this port.
cficonPortIfIndex
The interface index of this port. For ports that are not installed, this object would be zero.
cficonPortAddrNumTable
A table listing the association of Port address to port number.
cficonPortAddrNumEntry
A cficonPortAddrNumTable entry. Each entry provides the port address to port number mapping.
cficonPortAddrPortAddr
The port address of this port.
cficonPortAddrPortNumber
The port number of this port.
cficonPortNumAddrTable
A table listing the association of Port number to its port number.
cficonPortNumAddrEntry
A cficonPortNumAddrTable entry. Each entry provides a mapping between the port number and its port number.
portAddrPortNumber
The port number of this port.
portAddress
The port address of this port.
cficonDirHistTable
A table listing the director history buffer. Director History Buffer is a mechanism to determine those ports that have changed their configuration for a particular value of a key counter. The FICON Director maintains a change vector of 256 bits (32 bytes) ...
cficonDirHistPortNumbers
The list of ports that have configuration change for a value of cficonDirHistKeyCounter. If a port has configuration change, its bit position will be 1. Each octet within the value of an object of this type, specifies a set of eight ports, with the first ...
cficonStatsTable
A table listing the FICON Statistics .
cficonStatsEntry
An entry listing the FICON statistics for FICON port.
cfStatsFramePacingTime
Number of 2.5 microsecond units that frame transmission is blocked due to zero credit.
cfStatsDispErrorsInFrame
Number of frames with disparity errors.
cfStatsEOFErrs
Number of frames with EOF errors.
cfStatsDispErrsOutOfFrame
Number of frames with OOF errors.
cfStatsInvalidOrderSets
Number of invalid or unrecognizable Order Sets outside of frames.
cfStatsErrorSummary
This counter contains a sum of the errors counted by a set of the other defined error counters.
cficonShowPorts
An object to control which ports are displayed. If set to all(1), all the ports, regardless whether they are installed or not are displayed in the cficonPortTable and cificonPortRunCfgTable. If set to 'installed', only the ports that are installed ports a ...
cficonLinkIncidentEntry
An entry listing the cficonLinkIncidentTable.
cficonLinkIncident
The type of link incident that occurred on an interface. bitErrThreshExceeded - Bit Error Threshold exceeded. lossOfSignalOrSync - Loss of Signal or Sync message. nosReceived - NOS msg Received NOS - Non Operational State primitiveSeqTimeOut - ...
cficonCfgFileCupNameTable
A table listing the CUP names for each vsan in a configuration file.
cficonCfgFileCupNameEntry
A cficonCfgFileCupNameTable entry. Each entry provides the CUP name for a VSAN (identified by vsanIndex) and a file (identified by cficonCfgFilename). INDEX { vsanIndex,cficonCfgFilename } ::= { cficonCfgFileCupNameTable 1 } CficonCfgFileCupNameEntry : ...
cficonConfigCopyTable
A table of config-copy requests.
cficonConfigCopyEntry
A config-copy request. A management station wishing to create an entry should first generate a random serial number to be used as the index to this sparse table. The station should then create the associated instance of the row status object. This config ...
cficonConfigCopyIndex
Object which specifies a unique entry in the cficonConfigCopyTable. A management station wishing to initiate a config-copy operation should use a random value for this object when creating an instance of a cficonConfigCopyEntry.
cficonCopyState
Specifies the result of this config-copy request. This value of this object is instantiated only after the row has been instantiated, i.e. after the cficonCopyEntryRowStatus has been made active.
cficonCopyFailReason
An error string describing the reason the copy failed.
cficonCopyEntryRowStatus
The status of this table entry. Once the entry status is set to active, the associated entry cannot be modified until the request completes (cficonCopyState transitions to successful or failed state).
cficonAutoSaveState
The object indicates whether auto save state is enabled or disabled. Enabling the auto save state, saves the configuration to the configuration file whenever a configuration change is made. If the cficonAutoSaveState is disabled (false), the configuration ...
cficonPortMap1
The port map1. This object contains information specific to third party vendor and the usage is vendor specific. Each record is 6 bytes long and there can be up to 42 records in this object. Each record consists of the following - 0-3 bytes - IfIndex byt ...
cficonPortMapTable
The port map table. This table contains the list of port map objects to carry the information of IfIndex, port Address, unit Type and Port Number for all ports. ::= { ciscoFiconPortMap 8 } SYNTAX CficonPortMapEntry MAX-ACCESS not-accessible ...
cficonSlotReservedPN
Chassis slot port numbers. Reserved port numbers for one chassis slot. There can be up to 64 port numbers reserved for each slot in the chassis. ::= { cficonSlotPortNumEntry 2 } -- -- Reserved Port Number Array For Logical Ports -- SYNTAX OCTET ...
cficonRlirErlEntry
An entry (conceptual row) containing information about an Nx_Port which has registered to receive RLIRs on the VSAN indicated by vsanIndex.
cficonRlirErlFcId
The Fibre Channel Identifier (FC-ID) of the subscribing Nx_Port.
cficonRlirErlFormat
Indicates the device type for which the Nx_Port is interested in receiving RLIR ELS.
cficonRlirErlRegType
This object indicates the type of registration desired by the subscriber. conditionalRx(1) - the Nx_Port is registered as a valid recipient of subsequent RLIRs. But such an Nx_Port is chosen as the recipient of a link incident record only if no other reci ...
cficonInterfaceSwapNextIndex
Next unique index available for creating new entry in the FICON interface swap table.
cficonInterfaceSwapTable
This table provides a management application with the capability to swap the configuration of two specified interfaces. In FICON, a host associates a great deal of configuration data with a port-address. If the FICON port connecting the host to the switc ...
cficonInterfaceSwapEntry
A cficonInterfaceSwapTable entry contains 2 interface indices to be swapped among other objects. A management station wishing to create an entry should first obtain a unique serial number, e.g. get the cficonInterfaceSwapNextIndex scalar as the index to t ...
cficonInterfaceSwapIndex
An arbitrary index for the swap command.
cficonSwapInterfaceIndexFirst
The first port number that needs to be swapped .
cficonSwapInterfaceIndexSecond
The second port number that needs to be swapped.
cficonSwapInterfaceActionStatus
The status of the port swap request. pending - the request is waiting to be processed by the device. executing - the request is currently being processed by the device. success - the request has been completed successfully by the device. failure - the req ...
cficonSwapInterfaceFailReason
The reason of failed port swap request other - the failure is caused by other sub-module. none - no failure. dmFailure - the failure is caused by Domain Manager. ficonFailure - the failure is caused by FICON Manager. pmFailure - the failure is caused by P ...
cficonSwapInterfaceSystemError
A system error string readable by user for the failed swap action.
cficonSwapInterfaceEntryStatus
If this object is set to 'active(1)' then the port configurations of the ports specified by objects cficonSwapInterfaceIndexFirst and cficonSwapInterfaceIndexSecond will be swapped.
cficonPortSwapGroup
A collection of objects providing port swap functionality.
cficonVsanGroup
A group containing objects providing ficon information in a vsan.
cficonPortGroup
A group containing an object providing ficon port information.
cficonPortRunCfgGroup
A group containing an object providing ficon port information.
cficonCfgFileGroup
A collection of objects for the per VSAN config file table.
cficonPortNumIfGroup
A collection of objects giving association of a Port Number to Interface Index of the Port.
cficonPortAddrNumGroup
A collection of objects giving association of a port address to port number and interface index of the port.
cficonPortNumAddrGroup
A collection of objects for the port number to port Address translation table.
cficonDirHistGroup
A collection of objects for the Director History table.
cficonStatsGroup
A collection of objects for the FICON statistics table.
cifconShowPortGroup
A collection of objects for the FICON statistics table.
cficonLinkIncidentGroup
A collection of objects for the FICON incidents table.
cficonCfgFileCupNameGroup
A collection of objects for the FICON CUP name for the vsan in the configuration files.
cficonConfigCopyGroup
A collection of objects for the FICON configuration copy operation.
cficonAutoSaveStateGroup
A collection of objects for the FICON configuration copy auto save operation.
cficonPortMapGroup
A collection of objects for the FICON port maps.
cficonPortMapGroupRev1
A collection of objects for the FICON port maps.
cficonReservedPortNumGroup
A collection of objects for the reserved FICON port numbers.
cficonRlirErlGroup
A collection of objects for displaying RLIR ERL.
cficonInterfaceSwapGroup
A collection of objects providing port swap functionality.
cficonDefaultPortBlockGroup
A collection of objects providing default port block state.