CISCO-MDI-METRICS-MIB Download
This MIB module defines objects that describe the Media
Delivery Index (MDI). The MDI [RFC4445] measurement describes
the quality indicator of a network intended to delivery
applications such as streaming media, MPEG video, VoIP, or other
information sensitive to arrival time and packet loss.
IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges,
Firewalls, Repeaters.
OID list for CISCO-MDI-METRICS-MIB
- cfmMdiMetricsTable
- This table contains aggregate data maintained by a flow monitor for traffic flows for which it is computing MDI metrics. This table has an sparse dependent relationship on the cfmFlowMetricsTable (defined by the CISCO-FLOW-MONITOR-MIB), containing a row f ...
- cfmMdiMetricsEntry
- An entry describes cumulative and aggregate MDI metrics for a single traffic flow. The devices creates a row in the cfmMdiMetricsTable when a flow monitor starts monitoring a traffic flow and has been configured to compute MDI metrics for the same traffic ...
- cfmMdiMetricsCfgRateType
- This object indicates how the corresponding flow monitor computes the DF for the traffic flow.
- cfmMdiMetricsCfgBitRate
- This object indicates the units for the corresponding instance of cfmMdiMetricsCfgRate. The value of this column only has relevance if the corresponding instance of cfmMdiMetricsCfgRateType is 'ipBitRate' or 'mediaRate'.
- cfmMdiMetricsCfgRate
- This object indicates the configured bit rate used by the flow monitor to compute the DF for the traffic flow. The value of this column only has relevance if the corresponding instance of cfmMdiMetricsCfgRateType is 'ipBitRate' or 'mediaRate'.
- cfmMdiMetricsCfgMediaPktSize
- This object indicates the configured media packet size used by the flow monitor to compute the DF for the traffic flow. The value of this column only has relevance if the corresponding instance of cfmMdiMetricsCfgRateType is 'mediaRate'.
- cfmMdiMetricsValid
- This object indicates which metrics are valid for the traffic flow: 'lostPkts' If this bit is set to '1', then the corresponding instance of cfmMdiMetricsLostPkts is valid. 'mediaLossRate' If this bit is set to '1', then the corresponding instances of cfm ...
- cfmMdiMetricsLostPkts
- This object indicates the number of packets lost for the traffic flow. The value of this column is valid if and only if the 'lostPkts' bit in the corresponding instance of cfmMdiMetricsValid is set to '1'.
- cfmMdiMetricsMlrScale
- This object indicates the scale factor for the corresponding instance of cfmMdiMetricsMlr. The value of this column is valid if and only if the 'mediaLossRate' bit in the corresponding instance of cfmMdiMetricsValid is set to '1'.
- cfmMdiMetricsMlrPrecision
- This object indicates the precision for the corresponding instance of cfmMdiMetricsMlr. The value of this column is valid if and only if the 'mediaLossRate' bit in the corresponding instance of cfmMdiMetricsValid is set to '1'.
- cfmMdiMetricsMlr
- This object indicates the MLR for the traffic flow since the flow monitor started collecting data for the traffic flow. The value of this column is valid if and only if the 'mediaLossRate' bit in the corresponding instance of cfmMdiMetricsValid is set to ...
- cfmMdiMetricsMdc
- This object indicates the media discontinuity events count for the traffic flow since the flow monitor started collecting data for the traffic flow. The value of this column is valid if and only if the 'mediaDiscontinuityCount' bit in the corresponding in ...
- cfmMdiMetricsTableChanged
- This object indicates the value of sysUpTime the last time the device created/destroyed a row in the cfmMdiMetricsTable.
- cfmMdiMetricsIntTable
- This table contains historic MDI metrics for the traffic flows monitored by each of the flow monitors supported by the device. This table has an sparse dependent relationship on the cfmFlowMetricsIntTable (defined by the CISCO-FLOW-MONITOR-MIB), containin ...
- cfmMdiMetricsIntEntry
- An entry describes MDI metrics collected for a previous measurement interval for a corresponding traffic flow.
- cfmMdiMetricsIntValid
- This object indicates which metrics are valid for the measurement interval: 'lostPkts' If this bit is set to '1', then the corresponding instance of cfmMdiMetricsIntLostPkts is valid. 'vbMin' If this bit is set to '1', then the corresponding instance of c ...
- cfmMdiMetricsIntLostPkts
- This object indicates the number of packets lost for the traffic flow during the measurement interval. The value of this column is valid if and only if the 'lostPkts' bit in the corresponding instance of cfmMdiMetricsValid is set to '1'.
- cfmMdiMetricsIntVbMin
- This object indicates the minimum virtual buffer size computed for the traffic flow over the course of the measurement interval. The value of this column is valid if and only if the 'vbMin' bit in the corresponding instance of cfmMdiMetricsValid is set to ...
- cfmMdiMetricsIntVbMax
- This object indicates the maximum virtual buffer size computed for the traffic flow over the course of the measurement interval. The value of this column is valid if and only if the 'vbMax' bit in the corresponding instance of cfmMdiMetricsIntValid is set ...
- cfmMdiMetricsIntMrUnits
- This object indicates the units for the corresponding instance of cfmMdiMetricsIntMr. The value of this column is valid if and only if the 'mediaRate' bit in the corresponding instance of cfmMdiMetricsIntValid is set to '1'.
- cfmMdiMetricsIntMr
- This object indicates the media rate used by the flow monitor to compute the DF for the traffic flow. If the corresponding instance of cfmMdiMetricsCfgRateType is 'auto', then the value of this column indicates the MR for the traffic flow during the meas ...
- cfmMdiMetricsIntDfScale
- This object indicates the scaling factor for the corresponding instance of cfmMdiMetricsIntDf. The value of this column is valid if and only if the 'delayFactor' bit in the corresponding instance of cfmMdiMetricsIntValid is set to '1'.
- cfmMdiMetricsIntDfPrecision
- This object indicates the precision for the corresponding instance of cfmMdiMetricsIntDf. The value of this column is valid if and only if the 'delayFactor' bit in the corresponding instance of cfmMdiMetricsIntValid is set to '1'.
- cfmMdiMetricsIntDf
- This object indicates the DF for the traffic flow during the measurement interval. The value of this column is valid if and only if the 'delayFactor' bit in the corresponding instance of cfmMdiMetricsIntValid is set to '1'.
- cfmMdiMetricsIntMlrScale
- This object indicates the scaling factor for the corresponding instance of cfmMdiMetricsIntMlr. The value of this column is valid if and only if the 'mediaLossRate' bit in the corresponding instance of cfmMdiMetricsIntValid is set to '1'.
- cfmMdiMetricsIntMlrPrecision
- This object indicates the precision for the corresponding instance of cfmMdiMetricsIntMlr. The value of this column is valid if and only if the 'mediaLossRate' bit in the corresponding instance of cfmMdiMetricsIntValid is set to '1'.
- cfmMdiMetricsIntMlr
- This object indicates the MLR for the traffic flow during the measurement interval. The value of this column is valid if and only if the 'mediaLossRate' bit in the corresponding instance of cfmMdiMetricsIntValid is set to '1'.
- cfmMdiMetricsIntMdc
- This object indicates the media discontinuity events count for the traffic flow during the measurement interval. The value of this column is valid if and only if the 'mediaDiscontinuityCount' bit in the corresponding instance of cfmMdiMetricsIntValid is s ...
- cfmeMdiCumulativeLostPkts
- This object identifier represents the monitored element describing the cumulative number of lost packets for a traffic flow (cfmMdiMetricsLostPkts).
- cfmeMdiCumulativeMlr
- This object identifier represents the monitored element describing the MDI MLR for a traffic flow (cfmMdiMetricsMlr).
- cfmeMdiCumulativeMdc
- This object identifier represents the monitored element describing the MDI MDC for a traffic flow (cfmMdiMetricsMdc).
- cfmeMdiLostPkts
- This object identifier represents the monitored element describing the number of lost packets for a traffic flow during the last measurement interval (cfmMdiMetricsIntLostPkts).
- cfmeMdiDf
- This object identifier represents the monitored element describing the MDI DF for a traffic flow during the last measurement interval (cfmMdiMetricsIntDf).
- cfmeMdiMlr
- This object identifier represents the monitored element describing the MDI MLR for a traffic flow during the last measurement interval (cfmMdiMetricsIntMlr).
- cfmeMdiMdc
- This object identifier represents the monitored element describing the MDI MDC for a traffic flow during the last measurement interval (cfmMdiMetricsIntMdc).
- cfmMdiMetricsGroup
- This group contains objects that describe MDI metrics.
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.