CISCO-NETSYNC-MIB

CISCO-NETSYNC-MIB Download

MIBs list

The Synchronous Ethernet (SyncE) MIB is defined for monitoring network synchronization based on ITU-T G.781 clock selection. Synchronous Ethernet (SyncE) is a standard defined for delivering timing to the remote NEs through a Packet Network. SyncE is well defined by ITU-T which included G.8261, G.8262, G.8264 and G.781. It leverages the PHY layer of Ethernet to transmit frequency to the remote sites. Its functionality and accuracy mimics that of the SONET/SDH network because of its physical layer characteristic. In order to allow best clock source traceabiliy, correctly define the timing source and helps preventing timing loop, Synchronization Status Message is required for SyncE. This is similar to SONET/SDH. However, since SONET/SDH use 4 bits from the two S bytes in the SONET/SDH overhead frame for such message, Ethernet relies on a different channel called ESMC (Ethernet Synchronization Messaging Channel) which is based on IEEE 802.3 Organization Specific Slow Protocol.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-NETSYNC-MIB

cnsClkSelGlobalTable
G.781 clock selection process table. This table contains the global parameters for the G.781 clock selection process.
cnsClkSelGlobalEntry
An entry is added to cnsClkSelGlobalTable when G.781 clock selection is enabled in the device configuration. The entry is removed when G.781 clock selection is removed from the configuration.
cnsClkSelGloProcIndex
An index that uniquely represents a clock selection process. This index is assigned arbitrarily by the system and may not be persistent across reboots.
cnsClkSelGlobProcessMode
This object indicates the QL mode of the network synchronization clock selection process as described in ITU-T standard G.781 section 5.12. ::= { cnsClkSelGlobalEntry 2 } SYNTAX CiscoNetsyncClockMode MAX-ACCESS read-only STATUS curr ...
cnsClkSelGlobNetsyncEnable
This object indicates whether the G.781 clock selection is enabled or not. 'true' - G.781 clock selection is enabled 'false' - G.781 clock selection is disabled
cnsClkSelGlobRevertiveMode
This object indicates the revertive mode setting in the G.781 clock selection process. The switching of clock sources can be made revertive or non-revertive. In non-revertive mode, an alternate clock source is maintained even after the original clock sour ...
cnsClkSelGlobESMCMode
This object indicates if global ESMC is enabled. With ESMC enabled globally, the system is capable of handling ESMC messages.
cnsClkSelGlobEECOption
This object indicates the network synchronization EEC (Ethernet Equipment Clock) option.
cnsClkSelGlobNetworkOption
This object indicates the synchronization network option.
cnsClkSelGlobHoldoffTime
This object indicates the global holdoff time in the G.781 clock selection process.
cnsClkSelGlobWtrTime
This object indicates the global wait-to-restore time in the G.781 clock selection process.
cnsClkSelGlobNofSources
This object indicates the number of synchronization sources currently configured for the G.781 clock selection process.
cnsClkSelGlobLastHoldoverSeconds
This object indicates the duration of the last holdover period in seconds. If the holdover duration is less than a second, the object will carry the value zero.
cnsClkSelGlobCurrHoldoverSeconds
This object indicates the duration of the current holdover period. If a system clock is in holdover mode, the object carries the current holdover duration in seconds. If the system clock is not in holdover, the object carries the value 0.
cnsSelectedInputSourceTable
T0 selected clock source table. This table contains the selected clock source for the input T0 clock.
cnsSelectedInputSourceEntry
An entry is created in the table when the G.781 clock selection process has successfully selected a T0 clock source. The entry shall remain during the time the G.781 clock selection process remains enabled.
cnsSelInpSrcNetsyncIndex
An index that uniquely represents an entry in this table. This index is assigned arbitrarily by the clock selection process and may not be persistent across reboots.
cnsSelInpSrcName
This object indicates the name of the selected T0 clock.
cnsSelInpSrcIntfType
This object indicates the type of the selected T0 clock.
cnsSelInpSrcQualityLevel
This object indicates the selected T0 clock source's effective quality level, which is the derived clock quality based on the three factors: (a) Received quality level. (b) Configured Rx quality level. This factor supersedes (a). (c) System overridden qu ...
cnsSelInpSrcPriority
This object indicates the configured priority of the selected T0 clock. A smaller value represents a higher priority.
cnsSelInpSrcTimestamp
This object indicates the timestamp of the T0 clock source being selected by the G.781 clock selection process.
cnsSelInpSrcFSW
This object indicates the forced switching flag. Forced switching, as described in G.781, is used to override the currently selected synchronization source. The 'true' value indicates the currently selected clock source is a result of the forced switching ...
cnsSelInpSrcMSW
This object indicates the manual switching flag. The 'true' value indicates the currently selected clock source is a result of the manual switch command. The command allows a user to select a synchronization source assuming it is enabled, not locked out, ...
cnsInputSourceTable
T0 clock source table. This table contains a list of input sources for input T0 clock selection.
cnsInputSourceEntry
An entry is created in the table when a user adds a T0 clock source in the configuration. An entry is removed in the table when a user removes a T0 clock source from the configuration.
cnsInpSrcNetsyncIndex
An index that uniquely represents an entry in this table. This index is assigned arbitrarily by the clock selection process and may not be persistent across reboots.
cnsInpSrcName
This object indicates the name of an input clock source configured for the T0 clock selection.
cnsInpSrcIntfType
This object indicates the type of an input clock source configured for the T0 clock selection.
cnsInpSrcPriority
This object indicates the priority of an input clock source configured for the T0 clock selection. A smaller value represents a higher priority.
cnsInpSrcESMCCap
This object indicates the ESMC capability of an input clock source configured for the T0 clock selection. This is applicable only to Synchronous Ethernet input clock source identified by cnsInpSrcIntfType 'netsyncIfTypeEthernet'.
cnsInpSrcSSMCap
This object indicates the SSM capability of an input clock source configured for the T0 clock selection. This is applicable only to any synchronous interface clock source except SyncE interface, which is identified by cnsInpSrcIntfType 'netsyncIfTypeEther ...
cnsInpSrcQualityLevelTxCfg
This object indicates the configured transmit clock quality level of an input clock source.
cnsInpSrcQualityLevelRxCfg
This object indicates the configured receive clock quality level of an input clock source.
cnsInpSrcQualityLevelTx
This object indicates the most recent clock quality level transmitted on the input clock source.
cnsInpSrcQualityLevelRx
This object indicates the last clock quality level received on the input clock source.
cnsInpSrcQualityLevel
This object indicates the current clock quality level of the input clock source. This is the effective quality which is derived from three values: 1) most recent clock quality level received, 2) forced clock quality level (entered via configuration) 3) o ...
cnsInpSrcHoldoffTime
This object indicates the hold-off time value of an input clock source. The hold-off time prevents short activation of signal failure is passed to the selection process. When a signal failure event is reported on a clock source, it waits the duration of ...
cnsInpSrcWtrTime
This object indicates the wait-to-restore time value of an input clock source. The wait-to-restore time ensures that a previous failed synchronization source is only again considered as available by the selection process if it is fault-free for a certain ...
cnsInpSrcLockout
This object indicates whether or not the lockout command has been applied to a clock source. The 'true' value means the clock source is not considered by the selection process.
cnsInpSrcSignalFailure
This object indicates whether or not a signal failure event is currently being reported on the input clock source.
cnsInpSrcAlarm
This object indicates whether or not an alarm event is currently being reported on the input clock source.
cnsInpSrcAlarmInfo
This object indicates the alarm reasons of an input clock source if an alarm event is being reported on it.
cnsInpSrcFSW
This object indicates the forced switching flag. Forced switching, as described in G.781, is used to override the currently selected synchronization source. The 'true' value indicates the currently selected clock source is a result of the forced switching ...
cnsInpSrcMSW
This object indicates the manual switching flag. The 'true' value indicates the currently selected clock source is a result of the manual switching. The switch allows a user to select a synchronization source assuming it is enabled, not locked out, not in ...
cnsExtOutputTable
T4 external output table. This table contains a list of T4 external outputs. Each T4 external output is associated with clock source(s) to be found in cnsT4ClockSourceTable. The clock selection process considers all the available clock sources and select ...
cnsExtOutputEntry
An entry is created in the table when a user adds a T4 external output in the configuration. A T4 external output configured input clock sources are defined in cnsT4ClockSourceTable. An entry is removed from the table when a user removes a T4 external ou ...
cnsExtOutListIndex
An index that uniquely represents an entry in this table. This index is assigned arbitrarily by the clock selection process and may not be persistent across reboots.
cnsExtOutSelNetsyncIndex
An index that uniquely represents the selected input clock source whose information is reported by a row in cnsT4ClockSourceTable. The index lists the value of cnsT4ClkSrcNetsyncIndex, which is the input clock source of the T4 external output selected by ...
cnsExtOutName
This object indicates the name of a T4 external output.
cnsExtOutIntfType
This object indicates the interface type of the T4 external output.
cnsExtOutQualityLevel
This object indicates the clock quality of the T4 external output.
cnsExtOutPriority
This object indicates the priority of the selected clock source for a T4 external output. A smaller value represents a higher priority.
cnsExtOutFSW
This object indicates the forced switching flag. Forced switching, as described in G.781, is used to override the currently selected synchronization source, The T4 selected synchronization source is identified by cnsExtOutSelNetsyncIndex, which contains t ...
cnsExtOutMSW
This object indicates the manual switching flag. The 'true' value indicates the currently selected T4 clock source is a result of the manual switch command. The command allows a user to select a synchronization source assuming it is enabled, not locked ou ...
cnsExtOutSquelch
This object indicates whether or not a T4 external output is squelched. Squelching is a sychronization function defined to prevent transmission of a timing signal with a quality that is lower than the quality of the clock in the receiving networks element ...
cnsT4ClockSourceTable
T4 clock source table. This table contains a list of input sources for a specific T4 external output. An entry shall be added to cnsExtOutputTable first. Then clock sources shall be added in this table for the selection process to select the appropriate T ...
cnsT4ClockSourceEntry
An entry is created in the table when a user adds a clock source to a T4 external output in the configuration. The T4 external output is defined in the T4 external output table. An entry is removed in the table when a user removes a T4 clock source from t ...
cnsT4ClkSrcNetsyncIndex
An index that uniquely represents an entry in this table. This index is assigned arbitrarily by the clock selection process and may not be persistent across reboots.
cnsT4ClkSrcName
This object indicates the name of a input clock source configured for the T4 clock selection.
cnsT4ClkSrcIntfType
This object indicates the type of an input clock source configured for the T4 clock selection.
cnsT4ClkSrcPriority
This object indicates the priority of an input clock source configured for the T4 clock selection. A smaller value represents a higher priority.
cnsT4ClkSrcESMCCap
This object indicates the ESMC capability of an input clock source configured for the T4 clock selection. This is applicable only to Synchronous Ethernet input clock source identified by cnsT4ClkSrcIntfType 'netsyncIfTypeEthernet'.
cnsT4ClkSrcSSMCap
This object indicates the SSM capability of an input clock source configured for the T4 clock selection. This is applicable only to any synchronous interface clock source except SyncE interface, which is identified by cnsT4ClkSrcIntfType 'netsyncIfTypeEth ...
cnsT4ClkSrcQualityLevelTxCfg
This object indicates the configured transmit clock quality level of a T4 input clock source.
cnsT4ClkSrcQualityLevelRxCfg
This object indicates the configured receive clock quality level of a T4 input clock source.
cnsT4ClkSrcQualityLevelTx
This object indicates the most recent clock quality level transmitted on the T4 input clock source.
cnsT4ClkSrcQualityLevelRx
This object indicates the last clock quality level received on the T4 input clock source.
cnsT4ClkSrcQualityLevel
This object indicates the current clock quality level of the T4 input clock source. This is the effective quality which is derived from three values: 1) most recent clock quality level received, 2) forced clock quality level (entered via configuration) 3 ...
cnsT4ClkSrcHoldoffTime
This object indicates the hold-off time value of a T4 input clock source. The hold-off time prevents short activation of signal failure is passed to the selection process. When a signal failure event is reported on a clock source, it waits the duration o ...
cnsT4ClkSrcWtrTime
This object indicates the wait-to-restore time value of a T4 input clock source. The wait-to-restore time ensures that a previous failed synchronization source is only again considered as available by the selection process if it is fault-free for a certai ...
cnsT4ClkSrcLockout
This object indicates whether or not the lockout command has been applied on a T4 clock source. The 'true' value means the clock source is not considered by the selection process.
cnsT4ClkSrcSignalFailure
This object indicates whether or not a signal failure event is currently being reported on the T4 input clock source.
cnsT4ClkSrcAlarm
This object indicates whether or not an alarm event is currently being reported on the T4 input clock source.
cnsT4ClkSrcAlarmInfo
This object indicates the alarm reasons of a T4 input clock source if an alarm event is being reported on the clock source.
cnsT4ClkSrcFSW
This object indicates the forced switching flag. Forced switching, as described in G.781, is used to override the currently selected synchronization source. The 'true' value indicates the currently selected T4 clock source is a result of the forced switch ...
cnsT4ClkSrcMSW
This object indicates the manual switching flag. The 'true' value indicates the currently selected T4 clock source is a result of the manual switching. The switch allows a user to select a synchronization source assuming it is enabled, not locked out, not ...
cnsInpSrcFailClear
This object indicates the clear status of a signal failure event. A value of 'true' means a signal failure event reported on a clock source has been cleared. A value of 'false' means a signal event has been reported on a clock source.
cnsInpSrcAlarmClear
This object indicates the clear status of an alarm event. A value of 'true' means an alarm event reported on a clock source has been cleared. A value of 'false' means an alarm event has been reported on a clock source.
cnsMIBEnableStatusNotification
A control object to enable/disable ciscoNetsyncSelectedT0Clock, ciscoNetsyncSelectedT4Clock, ciscoNetsyncInputSignalFailureStatus, ciscoNetsyncInputAlarmStatus notifications at the system level. This object should hold any of the below values. true - The ...
cnsClkSelGlobalObjectGroup
This group contains all objects referenced by the G.781 clock selection process table.
cnsSelectedInputSourceObjectGroup
This group contains all objects referenced by cnsSelectedInputSourceTable.
cnsInputSourceObjectGroup
This group contains all objects referenced by cnsInputSourceTable.
cnsExtOutputObjectGroup
This group contains all objects referenced by cnsExtOutputTable.
cnsT4ClkSrcObjectGroup
This group contains all objects referenced by cnsT4ClockSourceTable.
cnsMIBNotifEnablesGroup
The collection of objects which are used to enable notification. ::= { ciscoNetsyncMIBGroups 6 } ciscoNetsyncMIBNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { ciscoNetsyncSelectedT0Clock, ciscoNetsyncSelectedT4Clock, ciscoNetsyncInputSignalFailur ...

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.

MIBs list