CPQCMC

CPQCMC Download

MIBs list

Compaq Console Management Controller - (CMC) MIB

With the IPHost SNMP tool, you can monitor any SNMP objects of the CPQCMC . You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the CPQCMC .

OID list for CPQCMC

cpqCmcMibRevMajor
The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information, correct interpretation of data may require ...
cpqCmcMibRevMinor
The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
cpqCmcMibCondition
The overall condition (status) of the system (rack(s)) represented by this MIB. (2) OK (3) a minor problem, warning condition (yellow LED on CMC) (4) a major problem (red LED on CMC)
cpqCmcOsCommonPollFreq
The Insight Agents's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management sta ...
cpqCmcDeviceCondition
Condition of CMC device, (3) an overload of the 24V DC supply to the connected accessories occured (4) the overload-protection (fuse) has released
cpqCmcsetLanguage
Language of LCD
cpqCmcsetTempUnit
Unit of all temperature values and thresholds, Celsius or Fahrenheit
cpqCmcsetAudibleAlarm
Audible alarm in CMC unit: (2): silencing with button on CMC is enabled (3): silencing with button on CMC is disabled (4): audible alarm is off (general). On/off of audible alarm for each event is possible in cpqCmcsetupEvents-group
cpqCmcPassword
Password to get access to terminal or LCD
cpqCmcPasswordOption
Enable or disable password entry to get access to terminal or LCD
cpqCmcquitRelay1
Enable or disable acknowledging currently active alarm relay 1 (with 'ENTER' on CMC).
cpqCmcquitRelay2
Enable or disable acknowledging currently active alarm relay 2 (with 'ENTER' on CMC).
cpqCmclogicRelay1
Logic of Relay 1: (2) Relay will pick up in case of an alarm (3) Relay will release in case of an alarm (4) not used
cpqCmclogicRelay2
Logic of Relay 2: (2) Relay will pick up in case of an alarm (3) Relay will release in case of an alarm (4) not used
cpqCmcSetupTemp1Avail
Temperature sensor: (2) sensor available (3) sensor not available
cpqCmcSetupTemp1RelaysWarn
Alert handling of Alarm Relays in case of warning condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupTemp1RelaysMax
Alert handling of Alarm Relays in case of max. alarm condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupTemp1RelaysMin
Alert handling of Alarm Relays in case of min. alarm condition of temperature sensor 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupTemp1AudibleAlarmWarn
Alert handling of Audible Alarm of in case of warning condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupTemp1AudibleAlarmMax
Alert handling of Audible Alarm of in case of max. alarm condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupTemp1AudibleAlarmMin
Alert handling of Audible Alarm of in case of min. alarm condition of temperature sensor 1: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupTemp2Avail
Temperature sensor: (2) sensor available (3) sensor not available
cpqCmcSetupTemp2RelaysWarn
Alert handling of Alarm Relays in case of warning condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupTemp2RelaysMax
Alert handling of Alarm Relays in case of max. alarm condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupTemp2RelaysMin
Alert handling of Alarm Relays in case of min. alarm condition of temperature sensor 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupTemp2AudibleAlarmWarn
Alert handling of Audible Alarm of in case of warning condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupTemp2AudibleAlarmMax
Alert handling of Audible Alarm of in case of max. alarm condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupTemp2AudibleAlarmMin
Alert handling of Audible Alarm of in case of min. alarm condition of temperature sensor 2: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupFan1Avail
Fan 1: (2) Fan 1 available (3) Fan 1 not available
cpqCmcSetupFan1Relays
Alert handling of Alarm Relays in case of alarm condition of Fan 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupFan1AudibleAlarm
Alert handling of Audible Alarm of in case of alarm condition of Fan 1: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupFan2Avail
Fan 2: (2) Fan 2 available (3) Fan 2 not available
cpqCmcSetupFan2Relays
Alert handling of Alarm Relays in case of alarm condition of Fan 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupFan2AudibleAlarm
Alert handling of Audible Alarm of in case of alarm condition of Fan 2: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupVoltageAvail
Voltage monitoring: (2) available (3) not available
cpqCmcSetupVoltageRelaysMax
Alert handling of Alarm Relays in case of max. alarm condition of voltage monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupVoltageRelaysMin
Alert handling of Alarm Relays in case of min. alarm condition of voltage monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupVoltageAudibleAlarmMax
Alert handling of Audible Alarm of in case of max. alarm condition of voltage monitoring: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupVoltageAudibleAlarmMin
Alert handling of Audible Alarm of in case of min. alarm condition of voltage monitoring: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupHumidityAvail
Humidity sensor: (2) available (3) not available
cpqCmcSetupHumidityRelaysMax
Alert handling of Alarm Relays in case of max. alarm condition of humidity monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupHumidityRelaysMin
Alert handling of Alarm Relays in case of min. alarm condition of humidity monitoring: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupHumidityAudibleAlarmMax
Alert handling of Audible Alarm of in case of max. alarm condition of humidity monitoring: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupHumidityAudibleAlarmMin
Alert handling of Audible Alarm of in case of min. alarm condition of humidity monitoring: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupInput1Avail
Input 1 sensor: (2) available (3) not available
cpqCmcSetupInput1Relays
Alert handling of Alarm Relays in case of a warning condition of Input 1 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupInput1AudibleAlarm
Alert handling of Audible Alarm of in case of a warning condition of Input 1 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupInput1FansOff
Fan switching off if Door/Sidewall 1 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off
cpqCmcSetupInput1ShockSensor
Shock sensor function if Door/Sidewall 1 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)
cpqCmcSetupInput1Description
Descriptional text of Input1
cpqCmcSetupInput1Lock
Door/Sidewall 1 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices
cpqCmcSetupInput2Avail
Input 2 sensor: (2) available (3) not available
cpqCmcSetupInput2Relays
Alert handling of Alarm Relays in case of a warning condition of Input 2 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupInput2AudibleAlarm
Alert handling of Audible Alarm of in case of a warning condition of Input 2 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupInput2FansOff
Fan switching off if Door/Sidewall 2 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off
cpqCmcSetupInput2ShockSensor
Shock sensor function if Door/Sidewall 2 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)
cpqCmcSetupInput2Description
Descriptional text of Input2
cpqCmcSetupInput2Lock
Door/Sidewall 2 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices
cpqCmcSetupInput3Avail
Input 3 sensor: (2) available (3) not available
cpqCmcSetupInput3Relays
Alert handling of Alarm Relays in case of a warning condition of Input 3 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupInput3AudibleAlarm
Alert handling of Audible Alarm of in case of a warning condition of Input 3 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupInput3FansOff
Fan switching off if Door/Sidewall 3 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off
cpqCmcSetupInput3ShockSensor
Shock sensor function if Door/Sidewall 3 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)
cpqCmcSetupInput3Description
Descriptional text of Input3
cpqCmcSetupInput3Lock
Door/Sidewall 3 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices
cpqCmcSetupInput4Avail
Input 4 sensor: (2) available (3) not available
cpqCmcSetupInput4Relays
Alert handling of Alarm Relays in case of a warning condition of Input 4 (Door/Sidewall open): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupInput4AudibleAlarm
Alert handling of Audible Alarm of in case of a warning condition of Input 4 (Door/Sidewall open): (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupInput4FansOff
Fan switching off if Door/Sidewall 4 is opened: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off
cpqCmcSetupInput4ShockSensor
Shock sensor function if Door/Sidewall 4 is opened: (2) Shock Sensor is off (disabled) (3) Shock Sensor is on (enabled)
cpqCmcSetupInput4Description
Descriptional text of Input4
cpqCmcSetupInput4Lock
Door/Sidewall 4 is locked by: (2) no locking device (3) locking device 1 (4) locking device 2 (5) both locking devices
cpqCmcSetupLock1Avail
Door locking device 1: (2) device available (3) device not available, no alarm, if door is not locked
cpqCmcSetupLock1Relays
Alert handling of Alarm Relays in case of an alarm condition of Lock 1 (door not locked..): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupLock1RelaysDevice
Alert handling of Alarm Relays in case of an alarm condition of Locking device 1 (power fail, low battery...): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupLock1AudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Lock 1: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupLock1AudibleAlarmDevice
Alert handling of Audible Alarm of in case of an alarm condition of Locking device 1 (power fail, low battery..): (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupLock1Time
Time in seconds while the lock 1 is unlocked after getting an unlock-command
cpqCmcSetupLock1PwrFailUnlock
Unlock door in case of power fail of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupLock1BattLowUnlock
Unlock door in case of low battery of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupLock1NetFailUnlock
Unlock door in case of network failure: (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupLock1LifeFailUnlock
Unlock door in case of lifecheck failure (connection CMC<->locking device): (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupLock2Avail
Door locking device 2: (2) device available (3) device not available, no alarm, if door is not locked
cpqCmcSetupLock2Relays
Alert handling of Alarm Relays in case of an alarm condition of Lock 2 (door not locked..): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupLock2RelaysDevice
Alert handling of Alarm Relays in case of an alarm condition of Locking device 2 (power fail, low battery...): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupLock2AudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Lock 2: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupLock2AudibleAlarmDevice
Alert handling of Audible Alarm of in case of an alarm condition of Locking device 2 (power fail, low battery..): (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupLock2Time
Time in seconds while the lock 2 is unlocked after getting an unlock-command
cpqCmcSetupLock2PwrFailUnlock
Unlock door in case of power fail of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupLock2BattLowUnlock
Unlock door in case of low battery of locking device: (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupLock2NetFailUnlock
Unlock door in case of network failure: (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupLock2LifeFailUnlock
Unlock door in case of lifecheck failure (connection CMC<->locking device): (2) disabled (3) auto unlock the door (4) unlock door with remote signal
cpqCmcSetupSmokeAvail
Smoke sensor: (2) available (3) not available
cpqCmcSetupSmokeRelays
Alert handling of Alarm Relays in case of an alarm condition of Smoke Sensor: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupSmokeAudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Smoke Sensor: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupSmokeFansOff
Fan switching off if in case of smoke-alarm: (2) both fans would be switched off (3) only fan1 will be switched off (4) only fan2 will be switched off (5) no fan will be switched off
cpqCmcSetupSmokeUnlock
Lock is unlocked in case of smoke-alarm: (2) both locks will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) no lock will be unlocked
cpqCmcSetupShockAvail
Shock sensor: (2) available (3) not available
cpqCmcSetupShockRelays
Alert handling of Alarm Relays in case of an alarm condition of Shock Sensor: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupShockAudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Shock Sensor: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupShockSensitivity
Sensitivity of shock-sensor. 1 = low sensitivity, 10 = high sensitivity
cpqCmcSetupAux1Avail
Aux 1 sensor: (2) available (3) not available
cpqCmcSetupAux1Relays
Alert handling of Alarm Relays in case of an alarm condition of Aux 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupAux1AudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Aux 1: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupAux1InputType
Type of other digital input (used for any digital signal): (2) contact is normally open, no alarm if contact is open, alarm if contact is closed (3) contact is normally closed, no alarm if contact is closed, alarm if contact is open
cpqCmcSetupAux1Description
Descriptional text of the digital input (Aux1)
cpqCmcSetupAux1Unlock
Lock will be unlocked with Aux-Input 1: (2) no lock will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) both locks will be unlocked
cpqCmcSetupAux2Avail
Aux 2 sensor: (2) available (3) not available
cpqCmcSetupAux2Relays
Alert handling of Alarm Relays in case of an alarm condition of Aux 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupAux2AudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Aux 2: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupAux2InputType
Type of other digital input (used for any digital signal): (2) contact is normally open, no alarm if contact is open, alarm if contact is closed (3) contact is normally closed, no alarm if contact is closed, alarm if contact is open
cpqCmcSetupAux2Description
Descriptional text of the digital input (Aux2)
cpqCmcSetupAux2Unlock
Lock will be unlocked with Aux-Input 2: (2) no lock will be unlocked (3) only lock1 will be unlocked (4) only lock2 will be unlocked (5) both locks will be unlocked
cpqCmcSetupAlarm1Relays
Alert handling of Alarm Relays in case of an alarm condition of Alarm 1: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupAlarm1AudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Alarm 1: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupAlarm1Description
Descriptional text of alarm 1
cpqCmcSetupAlarm2Relays
Alert handling of Alarm Relays in case of an alarm condition of Alarm 2: (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
cpqCmcSetupAlarm2AudibleAlarm
Alert handling of Audible Alarm of in case of an alarm condition of Alarm 2: (2) Start Audible Alarm (3) No Audible Alarm
cpqCmcSetupAlarm2Description
Descriptional text of alarm 2
cpqCmcSetupDate
actual Date in format DD.MM.YYYY
cpqCmcSetupTime
actual Time in format HH:MM:SS, HH (0-23), MM (0-59), SS (0-59)
cpqCmcThresholdMaxTemp1
Threshold value maximum temperature 1
cpqCmcThresholdWarningTemp1
Threshold value warning temperature 1
cpqCmcThresholdMinTemp1
Threshold value minimum temperature 1
cpqCmcThresholdMaxTemp2
Threshold value maximum temperature 2
cpqCmcThresholdWarningTemp2
Threshold value warning temperature 2
cpqCmcThresholdMinTemp2
Threshold value minimum temperature 2
cpqCmcThresholdFan1
Threshold Fan 1 in deg F or deg C, Fan 1 will start if temperature 1 exceeds this value
cpqCmcThresholdFan1Hysteresis
Hystersis of Fan 1, Fan 1 will stop if temperature 1 falls below value of cpqCmcThresholdFan1 minus cpqCmcThresholdFan1Hysteresis
cpqCmcThresholdFan2
Threshold Fan 2 in deg F or deg C, Fan 2 will start if temperature 2 exceeds this value
cpqCmcThresholdFan2Hysteresis
Hystersis of Fan 2, Fan 2 will stop if temperature 2 falls below value of cpqCmcThresholdFan2 minus cpqCmcThresholdFan2Hysteresis
cpqCmcThresholdMaxVoltage
Threshold high value Voltage alarm
cpqCmcThresholdMinVoltage
Threshold low value Voltage alarm
cpqCmcThresholdMaxHumidity
Threshold high value Humidity alarm
cpqCmcThresholdMinHumidity
Threshold low value Humidity alarm
cpqCmcTrapTableNumber
Number of trapTable entries. The number of trap-receivers
cpqCmcTrapTable
A list of trap-receiver entries
cpqCmcTrapEntry
Entries of trapTable
cpqCmcTrapIndex
Index for the trap-receiver-table. Its value ranges between 1 and the value of cpqCmcTrapTableNumber
cpqCmcTrapStatus
Enable or disable trap receiver
cpqCmcTrapIPaddress
IP-address of trap-receiver
cpqCmcValueTemp1
Actual temperature value of temperature sensor 1 in deg C or deg F
cpqCmcValueTemp2
Actual temperature value of temperature sensor 2 in deg C or deg F
cpqCmcValueVoltage
Actual value of power supply (voltage monitoring and fans) in V
cpqCmcValueHumidity
Actual value of humidity 0..100%
cpqCmcValueOperatingTime
Operating time CMC-unit
cpqCmcStatusTemp1
The status of temperature 1, see thresholds of temperature 1: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) err ...
cpqCmcStatusTemp2
The status of temperature 2, see thresholds of temperature 2: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) err ...
cpqCmcStatusFan1
The status of fan 1: (2) fan is switched off by temperature sensor 1 (3) fan is switched on by temperature sensor 1 (4) fan is switched off by Manual Control (cpqCmcSetFan1) (5) fan is switched on by Manual Control (cpqCmcSetFan1) (6) fan is switched off ...
cpqCmcStatusFan2
The status of fan 2: (2) fan is switched off by temperature sensor 2 (3) fan is switched on by temperature sensor 2 (4) fan is switched off by Manual Control (cpqCmcSetFan2) (5) fan is switched on by Manual Control (cpqCmcSetFan2) (6) fan is switched off ...
cpqCmcStatusVoltage
The voltage-status, see thresholds of power supply: (2) voltage normal (3) voltage exceeds max. threshold (4) voltage drops under min. threshold (5) no power connected
cpqCmcStatusHumidity
The humidity-status, see thresholds of humidity: (2) humidity normal (3) humidity exceeds max. threshold (4) humidity drops under min. threshold (5) no sensor connected, not available (6) error, sensor disconnected
cpqCmcStatusInput1
The status of door/sidepanel 1, closed (2), open (3) or no sensor connected (4)
cpqCmcStatusInput2
The status of door/sidepanel 2, closed (2), open (3) or no sensor connected (4)
cpqCmcStatusInput3
The status of door/sidepanel 3, closed (2), open (3) or no sensor connected (4)
cpqCmcStatusInput4
The status of door/sidepanel 4, closed (2), open (3) or no sensor connected (4)
cpqCmcStatusLock1Lock
The status of door locking 1 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is u ...
cpqCmcStatusLock2Lock
The status of door locking 2 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is u ...
cpqCmcStatusSmoke
Status smoke-sensor, OK (2), smoke detected (3) or no sensor connected (4)
cpqCmcStatusShock
Status Shock sensor, OK (2), shock detected (3) or no sensor connected (4)
cpqCmcStatusAux1
Status aux. digital input
cpqCmcStatusAux2
Status aux. digital input
cpqCmcStatusAlarm1
Status of alarm 1, see cmpCmcsetAlarm1. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm1Description.
cpqCmcStatusAlarm2
Status of alarm 2, see cmpCmcsetAlarm2. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm2Description.
cpqCmcStatusLock1Dev
The status of door-locking device 1 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (7) Connection CMC->door locking devi ...
cpqCmcStatusLock2Dev
The status of door-locking device 2 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (6) Connection CMC->door locking devi ...
cpqCmcStatusAccess
Status access, for future use
cpqCmcSetLock1Lock
Set door locking device 1, see table With this command the management-station can set the conditions for the door locking device (2) Door will be locked (3) Door will be unlocked for a defined time, time can be changed, see cpqCmcSetupLock1Time (4) Door i ...
cpqCmcSetLock1Key
Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the management station can set the conditions for unlocking the door: (2) unlocking is disabled, no unlocking with keypad or remote input ...
cpqCmcSetLock2Lock
Set door locking device 2, see table With this command the management-station can set the conditions for the door locking device (2) Door will be locked (3) Door will be unlocked for a defined time, time can be changed, see cpqCmcSetupLock2Time (4) Door i ...
cpqCmcSetLock2Key
Enable or disable unlocking of the rack-door with external components like keypad or remote input. With this command the management-station can set the conditions for unlocking the door: (2) unlocking is disabled, no unlocking with keypad or remote input ...
cpqCmcSetMessage
Set message to CMC, for future use
cpqCmcSetAlarm1
Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an alarm-relay or the AudibleAlarm of the CMC. Can be used for alert-handling
cpqCmcSetAlarm2
Is used to set an alarm in the CMC from the management-station. With this command the management-station can i.e. switch on an alarm-relay or the AudibleAlarm of the CMC. Can be used for alert-handling
cpqCmcSetFan1
Is used for run and stop control of fan1. (2) fan will run and stop according to temperature of sensor 1 and threshold of fan1 (3) fan will run independant of temperature and threshold (4) fan will stop independant of temperature and threshold (3) and (4) ...
cpqCmcSetFan2
Is used for run and stop control of fan2. (2) fan will run and stop according to temperature of sensor 2 and threshold of fan2 (3) fan will run independant of temperature and threshold (4) fan will stop independant of temperature and threshold (3) and (4) ...
cpqCmcSetQuitRelay1
Status and quit of alarm relay 1. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 1 in case of alarm
cpqCmcSetQuitRelay2
Status and quit of alarm relay 2. (2) relay is switched because of an alarm (3) relay is not switched, no alarm (4) (set) will quit relay 2 in case of alarm
cpqCmcLogsNumber
Number of Log-entries
cpqCmcLogTable
Log-table
cpqCmcLogEntry
Log-table entries
cpqCmcLogIndex
Index for the Log-table. Its value ranges between 1 and the value of cpqCmcLogsNumber
cpqCmcLogDate
Date of log information.
cpqCmcLogTime
Time of log information.
cpqCmcLogText
Log information.
cpqCmcLogClass
Status of log information.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now. Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access. The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.

MIBs list