Compaq Intelligent Drive Array information

With the IPHost SNMP tool, you can monitor any SNMP objects of the CPQIDA. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the CPQIDA .

OID list for CPQIDA

cpqDaMibRevMajor
The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the support ...
cpqDaMibRevMinor
The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
cpqDaMibCondition
The overall condition (status) of the system represented by this MIB.
cpqDaNw3xDriverName
Compaq Array Controller Driver Interface Name. This is the name of the device driver for the Compaq Array Controllers.
cpqDaNw3xDriverVer
Compaq Array Controller Driver Interface Version. This is the version number of the device driver for the Compaq Array Controllers.
cpqDaNw3xPollType
Compaq Array Controller Driver Interface Poll Type. The Insight Agent collects information from the device driver in two ways: Polled (2) Indicates that the information is periodically requested and stored by the server based agent and is available when r ...
cpqDaNw3xPollTime
Compaq Array Controller Driver Interface Poll Time. If the Poll Type is Polled, this value shows how frequently, in seconds, the instrument agent requests Information from the device driver. For example, if the Poll Type is Polled and the Poll Time is two ...
cpqDaNw3xDriverStatTable
Compaq Array Controller Driver Statistics Table. This is a table of logical drive statistics which are gathered by the device driver.
cpqDaNw3xDriverStatEntry
Compaq Array Controller Driver Statistics Table Entry. One entry in the driver statistics table. Each entry represents a logical drive for which the statistics are kept.
cpqDaNw3xCntlrIndex
Compaq Array Controller Index. This maps the logical drives into their respective controllers. This controller index matches the controller group entries.
cpqDaNw3xLogDrvIndex
Compaq Array Logical Drive Index. This is the logical drive number which keeps track of multiple instances of logical drives which are on the same controller. For each controller index value, the logical drive index starts at 1 and increments for each log ...
cpqDaNw3xTotalReads
Compaq Array Logical Drive Total Reads. This shows the total number of reads performed by the IDA device driver to this logical drive. This number is reset each time the device driver is loaded for this logical drive.
cpqDaNw3xTotalWrites
Compaq Array Logical Drive Total Writes. This shows the total number of writes performed by the IDA device driver to this logical drive. This number is reset each time the device driver is loaded for this logical drive.
cpqDaNw3xCorrReads
Compaq Array Logical Drive Corrected Reads. This is the total number of read commands sent to the specified logical drive which had to be corrected by fault tolerance. This number is reset each time the device driver is loaded for this logical drive. If ...
cpqDaNw3xCorrWrites
Compaq Array Logical Drive Corrected Writes. This is the total number of write commands sent to the specified logical drive which had to be corrected by fault tolerance. This number is reset each time the device driver is loaded for this logical drive. I ...
cpqDaNw3xFatalReads
Compaq Array Logical Drive Fatal Reads. This is the total number of read commands sent to the specified logical drive which failed. This number is reset each time the device driver is loaded for this logical drive. The drive array was unable to correct t ...
cpqDaNw3xFatalWrites
Compaq Array Logical Drive Fatal Writes. This is the total number of write commands sent to the specified logical drive which failed. This number is reset each time the device driver is loaded for this logical drive. The drive array was unable to correct ...
cpqDaNw3xVolMapTable
Volume Map Table. This is a table of NetWare volumes which map into the logical drives
cpqDaNw3xVolMapEntry
Volume Map Table Entry. One entry in the volume map table. Each entry represents a logical drive for which the volume map is kept.
cpqDaNw3xVolCntlrIndex
Compaq Array Controller Index. This maps the logical drives into their respective controllers. This controller index matches the controller group entries.
cpqDaNw3xVolLogDrvIndex
Compaq Array Logical Drive Index. This is the logical drive number which keeps track of multiple instances of logical drives which are on the same controller. For each controller index value, the logical drive index starts at 1 and increments for each log ...
cpqDaNw3xVolMap
NetWare Volume Map. This is a data structure containing the volume mappings for this logical drive. There are 8 entries in a volume mapping. Each entry has the following format. An entry can be null indicating no mapping exists. BYTE Name[16] BYTE S ...
cpqDaOsCommonPollFreq
The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management stat ...
cpqDaOsCommonModuleTable
A table of software modules that provide an interface to the device this MIB describes.
cpqDaOsCommonModuleEntry
A description of a software module that provides an interface to the device this MIB describes.
cpqDaOsCommonModuleIndex
A unique index for this module description.
cpqDaOsCommonModuleName
The module name.
cpqDaOsCommonModuleVersion
The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the agent cannot provide the module version.
cpqDaOsCommonModuleDate
The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 ...
cpqDaOsCommonModulePurpose
The purpose of the module described in this entry.
cpqDaOsCommonCollectionReset
Drive Array MIB Collection Reset. This variable is used to force the collection agent for this MIB to scan the associated hardware for configuration changes. The following values are defined: other(1) The agent is unable to determine if collection reset i ...
cpqDaCntlrTable
Compaq Array Controller Table.
cpqDaCntlrEntry
Compaq Array Controller Entry.
cpqDaCntlrIndex
Compaq Array Controller Index. This value is a logical number whose meaning is OS dependent. Each physical controller has one unique controller number associated with it.
cpqDaCntlrModel
Compaq Array Controller Model. The type of controller card. The valid types are: Other (1) You may need to upgrade your driver software and\or instrument agent(s). You have a drive array controller in the system that the instrument agent does not recog ...
cpqDaCntlrFWRev
Compaq Array Controller Firmware Revision. The firmware revision of the Compaq Drive Array Controller. This value can be used to help identify a particular revision of the controller.
cpqDaCntlrStndIntr
The status of the Standard Interface. The Standard Interface is how DOS communicates with a drive. Run the Compaq EISA Configuration Utility to change the Standard Interface setting. The following values are valid for Standard Interface: Other (1) The dev ...
cpqDaCntlrSlot
Compaq Array Controller Slot. This identifies the physical slot where the Compaq Array Controller resides in the system. For example, if this value is three, the Compaq Array Controller is located in slot three of your computer.
cpqDaCntlrCondition
The condition of the device. This value represents the overall condition of this controller, and any associated logical drives, physical drives, and array accelerators.
cpqDaCntlrProductRev
Compaq Array Controller Product Revision. The Product Revision of the Compaq Drive Array Controller. This value can be used to further identify a particular revision of the controller model. This will be one character ASCII value that is zero terminated. ...
cpqDaCntlrPartnerSlot
Compaq Array Controller Partner Slot. For duplexed array controllers, this is the slot number of the partner controller. For non-duplexed controllers, the value should be -1.
cpqDaCntlrCurrentRole
Compaq Array Controller Current Role. For duplexed array controllers, this is the controllers current role. The following values are valid: other (1) Indicates that the instrument agent does not recognize the role of the controller. You may need to upgr ...
cpqDaCntlrBoardStatus
Compaq Array Controller Board Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize the status of the controller. You may need to upgrade the instrument agent. ok (2) The array controller is operating pr ...
cpqDaCntlrPartnerBoardStatus
Compaq Array Controller Partner Board Status. The following values are valid: other (1) Indicates that the instrument agent does not recognize the status of the controller. You may need to upgrade the instrument agent. ok (2) The partner array controller ...
cpqDaCntlrBoardCondition
The condition of the device. This value represents the condition of the controller and any associated array accelerators.
cpqDaCntlrPartnerBoardCondition
The condition of the device. This value represents the condition of the controller and any associated array accelerators.
cpqDaCntlrDriveOwnership
Compaq Array Controller Drive Ownership. For duplexed controllers, indicates to which controller slot the shared devices are associated. The following values are valid: other (1) Indicates that the instrument agent does not recognize the status of the con ...
cpqDaCntlrSerialNumber
Compaq Array Controller Serial Number. The serial number of the array controller. This field will be a null (size 0) string if the controller does not support serial number.
cpqDaCntlrRedundancyType
Compaq Array Controller Redundancy Type. The following values are valid: other (1) Indicates that the instrument agent does not recognize the redundancy type of the controller. You may need to upgrade the instrument agent. notRedundant (2) The array cont ...
cpqDaCntlrRedundancyError
Compaq Array Controller Redundancy Error. The following values are valid: other (1) Indicates that the instrument agent does not recognize the redundancy error of the controller. You may need to upgrade the instrument agent. noFailure (2) No failures hav ...
cpqDaCntlrAccessModuleStatus
Compaq Array Controller RAID ADG Enabler Module Status. The following values are valid: other (1) Indicates that the agent does not recognize the RAID ADG Enabler Module status. You may need to upgrade the agent. notSupported (2) Indicates that the RAID ...
cpqDaCntlrDaughterBoardType
Compaq Array Controller Daughter Board Type. The following values are valid: other (1) Indicates that the agent does not recognize the daughter board type. You may need to upgrade the agent. notSupported (2) Indicates that the daughter board type field i ...
cpqDaCntlrHwLocation
A text description of the hardware location, on complex multi SBB hardware only, for the controller. A NULL string indicates that the hardware location could not be determined or is irrelevant.
cpqDaCntlrNumberOfBuses
Compaq Array Controller Number of Buses. This value is the number of buses on the controller.
cpqDaCntlrBlinkTime
Controller Physical Drive Blink Time Count. The controller blink time variable allows the drive tray LEDs of all physical drives attached to this controller to blink. This value indicates the amount of time, in tenths of a second, that the physical drive ...
cpqDaAccelTable
Array Accelerator Board Table.
cpqDaAccelEntry
Array Accelerator Board Entry.
cpqDaAccelCntlrIndex
Array Accelerator Board Controller Index. This value is a logical number whose meaning is OS dependent. The value has a direct mapping to the controller table index such that controller 'i' has accelerator table entry 'i'.
cpqDaAccelStatus
Array Accelerator Board Status. This describes the status of the Compaq 4MB Array Accelerator Write Cache. The status can be: Other (1) Indicates that the instrument agent does not recognize the status of the Array Accelerator. You may need to upgrade th ...
cpqDaAccelMemory
Write Cache Memory. This shows the amount of memory allocated for the write cache in kilobytes. Because data is kept in duplicate (mirrored), the actual amount of usable memory is half the amount shown.
cpqDaAccelBadData
Array Accelerator Board Bad Data. The following values are valid: None (2) Indicates that no data loss occurred. The battery packs were properly charged when the system was initialized. Possible (3) Indicates that at power up, the battery packs were not ...
cpqDaAccelErrCode
Array Accelerator Board Error Code. Use this to determine the status of the write cache operations. The status can be: Other (1) Indicates that the instrument agent does not recognize the error code. You may need to update your software. Invalid (2) Indi ...
cpqDaAccelBattery
Array Accelerator Board Battery Status. This monitors the status of each battery pack on the board. The batteries can only recharge when the system has power applied. The following values are valid: Other (1) Indicates that the instrument agent does not ...
cpqDaAccelReadErrs
Array Accelerator Board Read Errors. This shows the total number of read memory parity errors that were detected while reading from the Array Accelerator board. The mirrored copy of data on the board can be accessed to obtain correct data if a memory pari ...
cpqDaAccelWriteErrs
Array Accelerator Board Write Errors. This shows the total number of write memory parity errors that were detected while writing to the Array Accelerator board. Write parity errors occur when the system detects that information has not been transferred to ...
cpqDaAccelCondition
The condition of the device. This value represents the overall condition of this array accelerator.
cpqDaAccelReadMemory
Read Cache Memory. This shows the amount of memory allocated for the read cache in kilobytes. Because data is kept in duplicate (mirrored), the actual amount of usable memory is half the amount shown. Read cache is not available on IDA, IDA-2, IDA Expans ...
cpqDaAccelSerialNumber
Array Accelerator Serial Number. The serial number of the Array Accelerator. This field will be a null (size 0) string if the accelerator does not support serial number.
cpqDaAccelTotalMemory
Total Cache Memory. This value is the total amount of accelerator memory in kilobytes, including both battery-backed and non-battery-backed memory.
cpqDaLogDrvTable
Drive Array Logical Drive Table. A table of logical drive entries.
cpqDaLogDrvEntry
Drive Array Logical Drive Entry. A logical drive entry.
cpqDaLogDrvCntlrIndex
Drive Array Logical Drive Controller Index. This maps the logical drives into their respective controllers. Controller index 'i' under the controller group owns the associated drives in the logical drive group which use that index.
cpqDaLogDrvIndex
Drive Array Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are on the same controller. For each controller index value, the logical drive index starts at 1 and increments for each logical drive.
cpqDaLogDrvFaultTol
Logical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive. To change the fault tolerance mode, run the Compaq EISA Configuration Utility. The following values are valid for the Logical Drive Fault Tolerance: None (2) Fault to ...
cpqDaLogDrvStatus
Logical Drive Status. The logical drive can be in one of the following states: Ok (2) Indicates that the logical drive is in normal operation mode. Failed (3) Indicates that more physical drives have failed than the fault tolerance mode of the logical dri ...
cpqDaLogDrvAutoRel
Compaq Array Controller Logical Drive Auto-Reliability Delay. This value indicates how many seconds the logical drive will wait with no requests before beginning Auto-Reliability monitoring. For example, the default value is five, so the logical drive wil ...
cpqDaLogDrvRebuildBlks
Logical Drive Rebuild Blocks Remaining. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how many blocks of data still need to be rebuilt. When the value reaches zero, the rebuilding proces ...
cpqDaLogDrvHasAccel
Logical Drive Has Array Accelerator Board. This indicates whether the logical drive has an Array Accelerator board configured and enabled. The following values are valid: Other (1) Indicates that the instrument agent does not recognize the Array Accelera ...
cpqDaLogDrvAvailSpares
Drive Array Logical Drive Available Spares. This indicates if this logical drive has one or more spares designated for it that are not currently in use by another drive. Each octet present will be a physical drive ID that is an available spare for this lo ...
cpqDaLogDrvSize
Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this val ...
cpqDaLogDrvPhyDrvIDs
Drive Array Logical Drive Physical Drive IDs. This lists the physical drive IDs which are associated with this logical drive. These are the same IDs which can be used as indices into the physical drive table. Each byte of the string is an index.
cpqDaLogDrvCondition
The Logical Drive condition. This value represents the overall condition of this logical drive and any associated physical drives.
cpqDaLogDrvPercentRebuild
Logical Drive Percent Rebuild. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value is the percent complete of the rebuild. When the value reaches 100, the rebuilding process is complete. The drive ...
cpqDaLogDrvStripeSize
Logical Drive Stripe Size. This is the size of a logical drive stripe in kilobytes.
cpqDaLogDrvOsName
Logical Drive OS Name. The OS name for this array logical drive. This field will be a null (size 0) string if the agent does not support OS name.
cpqDaLogDrvBlinkTime
Logical Drive Physical Drive Blink Time Count. The logical drive blink time variable allows the drive tray LEDs of all physical drives in a logical drive to blink. This value indicates the amount of time, in tenths of a second, that the physical drive LE ...
cpqDaSpareTable
Drive Array Spare Table. A table of spare entries.
cpqDaSpareEntry
Drive Array Spare Entry. An entry in the spare table.
cpqDaSpareCntlrIndex
Drive Array Spare Controller Index. This index maps the spare drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqDaSparePhyDrvIndex
Drive Array Spare Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with the physical drive table.
cpqDaSpareStatus
Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Failed (3) The on-line spare has failed and is no longer available for use. Inactive (4) The monitored system has an on-line spare configu ...
cpqDaSpareReplacedDrv
Spare Replaced Drive. If the spare status is active(6) or building(5), then this has the physical drive number of the replaced drive. Otherwise a value of -1 will be returned.
cpqDaSpareRebuildBlks
Drive Array Spare Number Of Rebuild Blocks Left. If the spare status is building(5), then this is the number of blocks left to rebuild before completion. The data contained on the failed physical drive must be reconstructed from the fault tolerance data a ...
cpqDaSpareCondition
The Spare Drive condition. This value represents the overall condition of this spare drive and any associated physical drives.
cpqDaSpareBusNumber
Spare Drive SCSI Bus Number. The bus number indicates to which SCSI bus this spare drive is attached. The first instance is one and increments for each SCSI bus on a controller. A value of -1 will be returned if the spare drive is attached to a controll ...
cpqDaSpareBay
Spare Drive Bay Location. This value matches the bay location where the physical drive has been installed. Each bay is labeled with a separate number so that you can identify the location of the drive.
cpqDaSpareReplacedDrvBusNumber
Spare Replaced Drive Bus Number. If the spare status is active(6) or building(5), then this has the physical drive bus number of the replaced drive. If the value cannot be determined or is not applicable, the value is set to -1.
cpqDaSpareReplacedDrvBay
Spare Replaced Drive Bay. If the spare status is active(6) or building(5), then this has the physical drive bay number of the replaced drive. If the value cannot be determined or is not applicable, the value is set to -1.
cpqDaSparePercentRebuild
Drive Array Spare Percent Rebuild. If the spare status is building(5), then this is percent complete of of the rebuild. The data contained on the failed physical drive must be reconstructed from the fault tolerance data and copied to the spare so that the ...
cpqDaPhyDrvTable
Drive Array Physical Drive Table. A table of physical drive entries.
cpqDaPhyDrvEntry
Drive Array Physical Drive Entry. A physical drive entry.
cpqDaPhyDrvCntlrIndex
Drive Array Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqDaPhyDrvIndex
Drive Array Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the cpqDaPhyDrvCntlrIndex uniquely identify a specific physical drive.
cpqDaPhyDrvModel
Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. For example, you might see: COMPAQ 210MB CP3201. If a drive fails, note the model to identify the ty ...
cpqDaPhyDrvFWRev
Physical Drive Firmware Revision. This shows the physical drive revision number. If the firmware revision is not present, you have not properly initialized the drive array. If you suspect that a problem exists, schedule server down time to run Compaq Dia ...
cpqDaPhyDrvBay
Physical Drive Bay Location. This value matches the bay location where the physical drive has been installed. Each bay is labeled with a separate number so that you can identify the location of the drive.
cpqDaPhyDrvStatus
Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status: other (1) Indicates that the instrument agent does not recognize the drive. You may need to upgrade your instrument agent an ...
cpqDaPhyDrvFactReallocs
This shows the number of spare sectors available for remapping at the time the physical drive was shipped. The physical drive will use these spare sectors for remapping bad sectors that exist on the drive. Not all drives support factory reallocation.
cpqDaPhyDrvUsedReallocs
Physical Drive Used Reallocated Sectors. This shows the number of sectors of the reallocation area that have been used by the physical drive. To see how many sectors were originally available for use in the reallocation area, refer to the factory realloca ...
cpqDaPhyDrvRefHours
Reference Time in hours. This shows the total number of hours that a physical drive has been spinning since the drive was stamped. The drive will have either been stamped when it left the factory or when you ran Compaq Diagnostics on your new drive. You ...
cpqDaPhyDrvHReads
Sectors Read (high). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk drive during the reference time (phyDrvRefHours). The actual number of sectors read equals the phyDrvHReads times 2^32 plus th ...
cpqDaPhyDrvReads
Sectors Read (low). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk drive during the reference time (phyDrvRefHours). The actual number of sectors read equals the phyDrvHReads times 2^32 plus the ...
cpqDaPhyDrvHWrites
Sectors Written (high). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical disk drive during the reference hours (phyDrvRefHours). The actual number of sectors written equals the phyDrvHWrites times 2 ...
cpqDaPhyDrvWrites
Sectors Written (low). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical disk drive during the reference hours (phyDrvRefHours). The actual number of sectors written equals the phyDrvHWrites times 2^ ...
cpqDaPhyDrvHSeeks
Total Seeks (high). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physical disk drive during the reference hours (phyDrvRefHours). The actual number of seeks equals the phyDrvHSeeks times 2^32 plu ...
cpqDaPhyDrvSeeks
Total Seeks (low). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physical disk drive during the reference hours (phyDrvRefHours). The actual number of seeks equals the phyDrvHSeeks times 2^32 plus ...
cpqDaPhyDrvHardReadErrs
Hard Read Errors. This shows the number of read errors that have occurred on a drive that could not be recovered by a physical drive's Error Correction Code (ECC) algorithm or through retries during the reference time (phyDrvRefTime). Over time, a disk d ...
cpqDaPhyDrvRecvReadErrs
Recovered Read Errors. This shows the number of read errors corrected through physical drive retries during the reference time (phyDrvRefTime). Over time, all disk drives produce these errors. If you notice a rapid increase in the value for Recovered Rea ...
cpqDaPhyDrvHardWriteErrs
Hard Write Errors. This shows the number of write errors that could not be recovered by a physical drive during the reference time (phyDrvRefTime). Over time a disk drive may detect these errors. If you notice an increase in the value shown for Hard Write ...
cpqDaPhyDrvRecvWriteErrs
Recovered Write Errors. This shows the number of write errors corrected through physical drive retries or recovered by a physical drive during the reference time (phyDrvRefTime). Over time a disk drive may produce these errors. If you notice an increase i ...
cpqDaPhyDrvHSeekErrs
Seek Errors (High). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk drive detected a seek error during the reference hours (phyDrvRefHours). The actual number of seek errors equals the phyDrvHSeek ...
cpqDaPhyDrvSeekErrs
Seek Errors (low). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk drive detected a seek error during the reference hours (phyDrvRefHours). The actual number of seek errors equals the phyDrvHSeekE ...
cpqDaPhyDrvSpinupTime
Spin up Time in tenths of seconds. This is the time it takes for a physical drive to spin up to full speed. Disks require time to gain momentum and reach operating speed. As cars are tested to go from 0 mph to 60 mph in x number of seconds, drive manufact ...
cpqDaPhyDrvFunctTest1
Functional Test 1. This provides information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical drive currently operates when performing various tasks with the way it worked when it was new. A p ...
cpqDaPhyDrvFunctTest2
Functional Test 2. This provides information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical drive currently operates when performing various tasks with the way it worked when it was new. A p ...
cpqDaPhyDrvFunctTest3
Functional Test 3. This provides information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical drive currently operates when performing various tasks with the way it worked when it was new. A p ...
cpqDaPhyDrvDrqTimeouts
DRQ Timeouts. The number of times that a physical drive continued to request data, but did not get a command completion during the reference time (phyDrvRefTime). This value increases every time a DRQ timeout occurs for the physical drive. A defective dr ...
cpqDaPhyDrvOtherTimeouts
Other Timeouts. The number of times that a physical drive did not respond with an interrupt within a controller-defined period of time after a command had been issued during the reference time (phyDrvRefTime). This does not include DRQ timeouts. If you su ...
cpqDaPhyDrvSpinupRetries
Spin up Retries. The number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phyDrvRefTime). This value represents the spin-up retries that occurred since the last time you tur ...
cpqDaPhyDrvBadRecvReads
Recovery Failed (Bad) Read Error. The number of times a read error occurred while performing Automatic Data Recovery from this physical drive to another drive during the reference time (phyDrvRefTime). If a read error occurs, Automatic Data Recovery stops ...
cpqDaPhyDrvBadRecvWrites
Recovery Failed (Bad) Write Error. The number of times a write error occurred while performing Automatic Data Recovery from another drive to this physical drive during the reference time (phyDrvRefTime). If a write error occurs, Automatic Data Recovery st ...
cpqDaPhyDrvFormatErrs
Format Error. The number of times a format operation failed when the controller attempted to remap a bad sector during the reference time (phyDrvRefTime). Zero indicates that no format errors have occurred. The value increases each time a format error o ...
cpqDaPhyDrvPostErrs
Power On Self Test (Post) Error. The number of times that a physical drive failed its self test during the reference time (phyDrvRefTime). The physical drive does a self test each time power is applied to the system.
cpqDaPhyDrvNotReadyErrs
Drive Not Ready Errors. The number of times the physical drive failed after the spin up command was issued during the reference time (phyDrvRefTime). When the spin up command was issued, the drive failed to reach its ready state. If the current value is ...
cpqDaPhyDrvReallocAborts
Physical Drive Reallocation Aborts. The number of times the physical drive has failed due to an error that occurred when the controller was trying to reallocate a bad sector during the reference time (phyDrvRefTime). Zero (0) indicates that no Reallocati ...
cpqDaPhyDrvThreshPassed
Physical Drive Factory Threshold Passed (Exceeded). When the drive is shipped, certain thresholds have been set to monitor performance of the drives. For example, a threshold might be set for Spin up Time. If the time that it takes the drive to spin up ...
cpqDaPhyDrvHasMonInfo
Physical Drive Has Monitor Information. All of the physical disk table fields except for the physical disk status (phyDrvStatus) and the bay location (phyDrvBayLocation) are invalid unless this field has a value of true(2). If the value is false(1), you m ...
cpqDaPhyDrvCondition
The condition of the device. This value represents the overall condition of this physical drive.
cpqDaPhyDrvHotPlugs
Physical Drive Hot Plug Count. This value indicates the number of times this physical drive was hot-plugged (removed) from a Compaq ProLiant Storage System. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvMediaErrs
Physical Drive Media Failure Count. This value indicates the number of times this physical drive was failed due to unrecoverable media errors. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvHardwareErrs
Physical Drive Hardware Error Count. This value indicates the number of times this physical drive returned a bad hardware status. The drive may be failed if retries do not work. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvAbortedCmds
Physical Drive Aborted Command Failures. This value indicates the number of times this physical drive was failed due to aborted commands that could not be retried successfully. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvSpinUpErrs
Physical Drive Spin-Up Failure Count. This value indicates the number of times this physical drive was failed due to a failure of a spin-up command. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvBadTargetErrs
Physical Drive Bad Target Count. This value indicates the number of times this physical drive performed some action that did not conform to the SCSI-2 bus protocol. These actions will cause the SCSI bus to be reset. This is not supported by the IDA, IDA ...
cpqDaPhyDrvLocation
Drive Physical Location. This is the physical location of where the drive is located. The following values are defined: other(1) The location of the drive is not known. internal(2) The drive is located inside of the computer system box. external(3) The dr ...
cpqDaPhyDrvSize
Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so ...
cpqDaPhyDrvBusFaults
Physical Drive Bus Fault Count. This value indicates the number of times that a bus fault was detected for the drive by the controller. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvIrqDeglitches
Physical Drive IRQ Deglitch Count. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvHotPlug
Physical Drive Hot Plug Support Status. The following values are defined: other(1) The Insight Agent is unable to determine if this drive supports hot plug replacement. hotPlug(2) The drive supports hot plug replacement. nonhotPlug(3) The drive does not s ...
cpqDaPhyDrvPlacement
Physical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the drive is internal or external to the system chassis. internal(2) The drive is located in the system chassis. external(3) The drive is located outs ...
cpqDaPhyDrvBusNumber
Physical Drive SCSI Bus Number. The bus number indicates to which SCSI bus this physical drive is attached. The first instance is one and increments for each SCSI bus on a controller. A value of -1 will be returned if the physical drive is attached to a ...
cpqDaPhyDrvSerialNum
Physical Drive Serial Number. This is the serial number assigned to the physical drive. This value is based upon the serial number as returned by the SCSI inquiry command but may have been modified due to space limitations. This can be used for identific ...
cpqDaPhyDrvPreFailMonitoring
Compaq Drive Array Physical Drive Predictive Failure Monitoring. The following values are defined: other(1) The agent is unable to determine if the drive supports predictive failure monitoring. notAvailable(2) This drive does not support predictive failur ...
cpqDaPhyDrvCurrentWidth
Compaq Drive Array Physical Drive Current Width. The following values are defined: other(1) The agent is unable to determine the current negotiated data transfer width for this drive. narrow(2) The negotiated data transfer width for this drive is narrow ( ...
cpqDaPhyDrvCurrentSpeed
Compaq Drive Array Physical Drive Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determine the current negotiated data transfer speed for this drive. asynchronous(2) The negotiated data transfer speed for th ...
cpqDaPhyDrvFailureCode
Compaq Drive Array Physical Drive Failure Code. This value is the drive failure reason code returned by the array firmware. It is valid only when the drive is failed. If the drive is not failed, 0 is returned.
cpqDaPhyDrvBlinkTime
Physical Drive Blink Time Count. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs will continue to blink. A value of zero indicates the drive LEDs are not blinking. If the value cannot be determined or the dri ...
cpqDaPhyDrvSmartStatus
Physical Drive S.M.A.R.T Status. The following values are defined: other(1) The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive. ok(2) Indicates the drive is functioning properly. replaceDrive(3) Indica ...
cpqDaPhyDrvConfigurationStatus
Physical Drive Configuration Status. The following values are defined: other(1) The agent is unable to determine the configuration status of this physical drive. configured(2) Indicates the drive is configured to be part of a logical drive as either a mem ...
cpqDaPhyDrvErrTable
Drive Array Physical Drive Error Log Table. A table of physical drive entries. The Error Log Table is not supported by the IDA, IDA Expansion, or IDA-2 controllers.
cpqDaPhyDrvErrEntry
Drive Array Physical Drive Entry.
cpqDaPhyDrvErrCntlrIndex
Drive Array Physical Drive Error Log Controller Index. This index maps the physical drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqDaPhyDrvErrIDIndex
Drive Array Physical Drive Error Log Index. This index is used for selecting the physical drive table entry. This number, along with the cpqDaPhyDrvErrCntlrIndex uniquely identify a specific physical drive.
cpqDaPhyDrvErrIndex
Drive Array Physical Drive Error Log Index. This index is used for selecting the physical drive table entry. This number, along with the cpqDaPhyDrvErrCntlrIndex uniquely identify a specific physical drive.
cpqDaPhyDrvErrType
Physical Drive Error Log Error Type. The type of error in the error log. The valid types are: Other (1) Indicates that the instrument agent does not recognize the type of error in the error log. No Error (2) Indicates that this error log entry does not h ...
cpqDaPhyDrvScsiOp
Physical Drive Error Log SCSI Operation. This is the SCSI Command Operation Code byte associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI reference.
cpqDaPhyDrvScsiStatus
Physical Drive Error Log SCSI Status. This is the SCSI Status Code byte associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI reference.
cpqDaPhyDrvCamStatus
Physical Drive Error Log CAM Status. This is the SCSI CAM Status byte associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI reference.
cpqDaPhyDrvSenseKey
Physical Drive Error Log Sense Key. This is the SCSI Sense Key byte associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI reference.
cpqDaPhyDrvQualifier
Physical Drive Error Log Qualifier. This is the SCSI Additional Sense Code Qualifier byte (as returned by the Request Sense command) associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI refer ...
cpqDaPhyDrvSenseCode
Physical Drive Error Log Sense Code. This is the SCSI Sense Code associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI reference.
cpqDaPhyDrvBlockValid
Physical Drive Error Log Block Address Is Valid. The valid values are: False (1) Indicates that the Block Address object (cpqDaPhyDrvBlock) is not a valid address. True (2) Indicates that the Block Address object (cpqDaPhyDrvBlock) is a valid address.
cpqDaPhyDrvBlock
Physical Drive Error Log Block Address. This is the SCSI Block Address (as returned by the Request Sense Command) associated with the error log entry. For further specifications consult a SCSI-2 logical specification or other SCSI reference.
cpqDaPhyDrvTime
Physical Drive Error Log Reference Time. This gives a relative time stamp as to when the error log entry occurred. The Reference Time shows the number of hours that a physical drive has been spinning since the drive was initialized for monitor and perfor ...
cpqDaPhyDrvUserDesc
Physical Drive Error Log User Description. This is a string built by the agent which contains the Reference Time (cpqDaPhyDrvTime) and a brief description of the disk error associated with the particular error log entry. This field is being deprecated, a ...
cpqDaPhyDrvErrDesc
The index used to display an error associated with a physical drive. This number refers to an entry in a list of error strings enumerating the possible physical drive errors associated with a particular physical disk drive. The valid values are: DriveFail ...
cpqDaPhyDrvThrTable
Drive Array Physical Drive Threshold Table. A table of physical drive threshold entries.
cpqDaPhyDrvThrEntry
Drive Array Physical Drive Threshold Entry. A physical drive threshold entry.
cpqDaPhyDrvThrCntlrIndex
Drive Array Physical Drive Threshold Controller Index. This index maps the physical drive thresholds back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqDaPhyDrvThrIndex
Drive Array Physical Drive Threshold Index. This index maps the thresholds to a physical drive. The value of this index is the same as the one used with the physical drive table.
cpqDaPhyDrvThrUsedReallocs
Used Reallocated Sectors Maximum Threshold. This shows the maximum threshold of the reallocation area that has been used by the physical drive. This threshold is associated with the cpqDaPhyDrvUsedReallocs object in the Physical Drive Table.
cpqDaPhyDrvThrRefHours
Reference Time Maximum Threshold in hours. This shows the maximum threshold in hours that a physical drive has been spinning since the drive was stamped. This threshold is associated with the cpqDaPhyDrvRefHours object in the Physical Drive Table.
cpqDaPhyDrvThrHardReadErrs
Hard Read Errors Maximum Threshold. This shows the maximum threshold of read errors on a drive that could not be recovered by a physical drive's Error Correction Code (ECC) algorithm or through retries during the reference time (phyDrvRefTime). This thres ...
cpqDaPhyDrvThrRecvReadErrs
Recovered Read Errors Maximum Threshold. This shows the maximum threshold of read errors corrected through physical drive retries during the reference time (phyDrvRefTime). This threshold is associated with the cpqDaPhyDrvRecvReadErrs object in the Physic ...
cpqDaPhyDrvThrHardWriteErrs
Hard Write Errors Maximum Threshold. This shows the maximum threshold of write errors that could not be recovered by a physical drive during the reference time (phyDrvRefTime). This threshold is associated with the cpqDaPhyDrvHardWriteErrs object in the P ...
cpqDaPhyDrvThrRecvWriteErrs
Recovered Write Errors Maximum Threshold. This shows the maximum threshold of write errors corrected through physical drive retries or recovered by a physical drive during the reference time (phyDrvRefTime). This threshold is associated with the cpqDaPhyD ...
cpqDaPhyDrvThrHSeekErrs
Seek Errors Maximum Threshold (high). The cpqDaphyDrvThrHSeekErrs and the cpqDaphyDrvThrSeekErrs together show the maximum threshold of total number of times that the physical disk drive detected a seek error during the reference hours (phyDrvRefHours). T ...
cpqDaPhyDrvThrSeekErrs
Seek Errors Maximum Threshold (low). The cpqDaphyDrvThrHSeekErrs and the cpqDaphyDrvThrSeekErrs together show the maximum threshold of total number of times that the physical disk drive detected a seek error during the reference hours (phyDrvRefHours). Th ...
cpqDaPhyDrvThrSpinupTime
Spin up Time Maximum Threshold in tenths of seconds. This shows the maximum of time it takes for a physical drive to spin up to full speed. This threshold is associated with the cpqDaPhyDrvSpinupTime object in the Physical Drive Table.
cpqDaPhyDrvThrFunctTest1
Functional Test 1 Minimum Threshold. This provides the minimum threshold for information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical drive currently operate when performing various tasks ...
cpqDaPhyDrvThrFunctTest2
Functional Test 2 Minimum Threshold. This provides the minimum threshold for information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical drive currently operates when performing various tasks ...
cpqDaPhyDrvThrFunctTest3
Functional Test 3 Minimum Threshold. This provides the minimum threshold for information about a series of tests that indicate how well a physical drive works. These tests compare the way the physical drive currently operates when performing various tasks ...
cpqDaPhyDrvThrDrqTimeouts
DRQ Timeouts Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive continued to request data, but did not get a command completion during the reference time (phyDrvRefTime). This threshold is associated with the ...
cpqDaPhyDrvThrOtherTimeouts
Other Timeouts Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive did not respond with an interrupt within a controller-defined period of time after a command had been issued during the reference time (phyDrvR ...
cpqDaPhyDrvThrSpinupRetries
Spin up Retries Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phyDrvRefTime). This threshold is associated ...
cpqDaPhyDrvThrBadRecvReads
Recovery Failed (Bad) Read Error Maximum Threshold. This shows the maximum threshold of the number of times a read error occurred while performing Automatic Data Recovery from this physical drive to another drive during the reference time (phyDrvRefTime). ...
cpqDaPhyDrvThrBadRecvWrites
Recovery Failed (Bad) Write Error Maximum Threshold. This shows the maximum threshold of the number of times a write error occurred while performing Automatic Data Recovery from another drive to this physical drive during the reference time (phyDrvRefTime ...
cpqDaPhyDrvThrFormatErrs
Format Error Maximum Threshold. This shows the maximum threshold of the number of times a format operation failed when the controller attempted to remap a bad sector during the reference time (phyDrvRefTime). This threshold is associated with the cpqDaPhy ...
cpqDaPhyDrvThrPostErrs
Power On Self Test (Post) Error Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive failed its self test during the reference time (phyDrvRefTime). This threshold is associated with the cpqDaPhyDrvPostErrs obje ...
cpqDaPhyDrvThrNotReadyErrs
Drive Not Ready Errors Maximum Threshold. This shows the maximum threshold of the number of times the physical drive failed after the spin up command was issued during the reference time (phyDrvRefTime). When the spin up command was issued, the drive fai ...
cpqDaPhyDrvThrReallocAborts
Physical Drive Reallocation Aborts Maximum Threshold. This shows the maximum threshold of the number of times the physical drive has failed due to an error that occurred when the controller was trying to reallocate a bad sector during the reference time ( ...
cpqDaPhyDrvThrHotPlugs
Physical Drive Hot Plug Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can be hot-plugged (removed) from a Compaq ProLiant Storage System. This is not supported by the IDA, IDA Expansion, or IDA-2 con ...
cpqDaPhyDrvThrMediaErrs
Physical Drive Media Failure Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can be failed due to unrecoverable media errors. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers. This ...
cpqDaPhyDrvThrHardwareErrs
Physical Drive Hardware Error Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can return a bad hardware status. The drive may be failed if retries do not work. This is not supported by the IDA, IDA Ex ...
cpqDaPhyDrvThrAbortedCmds
Physical Drive Aborted Command Failures Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can be failed due to aborted commands that could not be retried successfully. This is not supported by the IDA, IDA Exp ...
cpqDaPhyDrvThrSpinUpErrs
Physical Drive Spin-Up Failure Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive was failed due to a failure of a spin-up command. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers. Th ...
cpqDaPhyDrvThrBadTargetErrs
Physical Drive Bad Target Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can perform some action that did not conform to the SCSI-2 bus protocol. These actions will cause the SCSI bus to be reset. This ...
cpqDaPhyDrvThrViUsedReallocs
Used Reallocated Sectors Threshold Has Been Violated. This is used to indicate whether the number of used sectors of the reallocation area for a physical drive has ever exceeded the maximum allowable threshold. The valid values are: false (1) Indicates th ...
cpqDaPhyDrvThrViSpinupTime
Spin up Time in tenths of seconds Threshold Has Been Violated. This is used to indicate whether the time it took for a physical drive to spin up to full speed has ever exceeded the maximum allowable threshold. The valid values are: false (1) Indicates tha ...
cpqDaPhyDrvThrViFunctTest1
Functional Test 1 Threshold Has Been Violated. This is used to indicate whether the percentage value returned from Functional Test 1 has every dropped below the allowable threshold for that test. The valid values are: false (1) Indicates that the Function ...
cpqDaPhyDrvThrViFunctTest2
Functional Test 2 Threshold Has Been Violated. This is used to indicate whether the percentage value returned from Functional Test 2 has every dropped below the allowable threshold for that test. The valid values are: false (1) Indicates that the Function ...
cpqDaPhyDrvThrViFunctTest3
Functional Test 3 Threshold Has Been Violated. This is used to indicate whether the percentage value returned from Functional Test 3 has every dropped below the allowable threshold for that test. The valid values are: false (1) Indicates that the Function ...
cpqDaPhyDrvThrBusFaults
Physical Drive Bus Fault Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can return a bus fault status. The drive may be failed if retries do not work. This is not supported by the IDA, IDA Expansion, ...
cpqDaPhyDrvThrIrqDeglitches
Physical Drive IRQ Deglitch Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive can return a IRQ deglitch status. The drive may be failed if retries do not work. This is not supported by the IDA, IDA Expan ...
cpqDaCntlrPerfTable
Drive Array Controller Performance Monitor Table. A table of controller entries supporting the performance monitor information.
cpqDaCntlrPerfEntry
Drive Array Controller Performance Monitor Entry. A performance monitor entry.
cpqDaCntlrPerfCntlrIndex
Drive Array Controller Performance Monitor Controller Index. This maps the performance monitor information into their respective controllers which support performance data.
cpqDaCntlrPerfInstance
Drive Array Controller Performance Monitor Instance Index. This maps the performance monitor information for a specific controller and sample interval to controllers which support performance data.
cpqDaCntlrPerfSampleInterval
Compaq Array Controller Performance Monitor Sample Interval. This value indicates the length of the performance interval for this controller and all logical volumes associated with this controller. This value is reported in seconds.
cpqDaCntlrPerfVersion
Compaq Array Controller Performance Monitor Version. This value specifies the version of the performance monitor interface.
cpqDaCntlrPerfCpuPercentBusy
Compaq Array Controller Performance Monitor Cpu Percent Busy. This value specifies the total CPU percent busy as a number from 0 to 100 inclusive. If the value cannot be determined, the value is set to -1.
cpqDaCntlrPerfCommandCount
Compaq Array Controller Performance Monitor Command Count. This value shows the total number of read and write commands processed in this sample. This value is expressed in read and write commands per second.
cpqDaCntlrPerfAvgLatency
Compaq Array Controller Performance Monitor Average Command Latency. This value shows the average command latency for this sample in 1/10,000 second units.
cpqDaLogDrvPerfTable
Drive Array Logical Drive Performance Monitor Table. A table of logical drive entries supporting the performance monitor information.
cpqDaLogDrvPerfEntry
Drive Array Logical Drive Performance Monitor Entry. A performance monitor entry.
cpqDaLogDrvPerfCntlrIndex
Drive Array Logical Drive Performance Monitor Controller Index. This maps the performance monitor information into their respective controllers which support performance data.
cpqDaLogDrvPerfIndex
Drive Array Logical Drive Performance Monitor Drive Index. This maps the performance monitor information into their respective logical drives which support performance data.
cpqDaLogDrvPerfInstance
Drive Array Logical Drive Performance Monitor Instance Index. This maps the performance monitor information for a specific controller, logical drive and sample interval to controllers which support performance data.
cpqDaLogDrvPerfSampleInterval
Compaq Array Logical Drive Performance Monitor Sample Interval. This value indicates the length of the performance interval for this controller and all logical volumes associated with this controller. This value is reported in seconds.
cpqDaLogDrvPerfAvgQueueDepth
Compaq Array Logical Drive Performance Monitor Average Queue Depth. This value indicates the average command queue depth of the logical volume.
cpqDaLogDrvPerfReads
Compaq Array Logical Drive Performance Monitor Reads. This value is the count of read requests for the logical volume expressed in reads per second.
cpqDaLogDrvPerfWrites
Compaq Array Logical Drive Performance Monitor Writes. This value is the count of write requests for the logical volume expressed in writes per second.
cpqDaLogDrvPerfTotalIO
Compaq Array Logical Drive Performance Monitor Total I/O. This value shows the total number of read and write requests for the logical volume expressed in reads and writes per second.
cpqDaLogDrvPerfCacheHits
Compaq Array Logical Drive Performance Monitor Cache Hits. This value shows the total number of read cache hits for the logical volume. This value is expressed in cache hits per second.
cpqDaLogDrvPerfCacheMisses
Compaq Array Logical Drive Performance Monitor Cache Misses. This value shows the total number of read cache misses for the logical volume. This value is expressed in cache misses per second.
cpqDaLogDrvPerfReadAheadSectors
Compaq Array Logical Drive Performance Monitor Read Ahead Sectors. This value shows the total number read ahead sectors pre-fetched for the logical volume for this interval. This value is expressed in sectors per second.
cpqDaLogDrvPerfSectorsRead
Compaq Array Logical Drive Performance Monitor Sectors Read. This value shows the number of sectors read for the logical volume for this interval. This value is expressed in sectors per second.
cpqDaLogDrvPerfSectorsWritten
Compaq Array Logical Drive Performance Monitor Sectors Written. This value shows the number of sectors written for the logical volume for this interval. This value is expressed in sectors per second.
cpqDaTapeDrvTable
Drive Array Tape Drive Table. A table of tape drive entries.
cpqDaTapeDrvEntry
Drive Array Tape Drive Entry. A tape drive entry.
cpqDaTapeDrvCntlrIndex
Compaq Drive Array Tape Drive Controller Index. This index maps the tape drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqDaTapeDrvBusIndex
Compaq Drive Array Tape Drive SCSI Bus Index. This is the controller SCSI bus to which the tape drive is attached.
cpqDaTapeDrvScsiIdIndex
Compaq Drive Array Tape Drive SCSI Index. This is the SCSI Target Id of the tape drive.
cpqDaTapeDrvLunIndex
Compaq Drive Array Tape Drive Logical Unit Number Index. This is the logical unit number of the tape drive.
cpqDaTapeDrvName
Compaq Drive Array Tape Drive Model Name. This is the model name of the tape drive. It can be used for identification purposes.
cpqDaTapeDrvSerialNumber
Compaq Drive Array Tape Drive Serial Number. This is the unit serial number for the tape drive. It can be used for identification purposes.
cpqDaTapeDrvFwRev
Compaq Drive Array Tape Drive Firmware Revision. This is firmware revision level of the tape drive. It can be used for identification purposes.
cpqDaTapeDrvStatus
Compaq Drive Array Tape Drive Status. The tape drive can be in one of the following states: other(1) The tape drive is in a state other than one of those listed below. ok(2) Indicates that the tape drive is in normal operation mode. No user action is nece ...
cpqDaTapeDrvCondition
Compaq Drive Array Tape Drive Condition. This value represents the overall condition of the tape drive.
cpqDaTapeDrvFwSubtype
Compaq Drive Array Tape Drive Firmware Subtype. This is used to differentiate the firmware versions which have the same tape drive type (as specified by cpqDaTapeDrvType). Tape drives will contain a value of 1 for this variable when they first ship, and ...
cpqDaTapeDrvType
Compaq Drive Array Tape Drive Type. This is the drives model, and can be used for identification purposes. The following values are defined: other(1) The management agent does not recognize this model. You may need to upgrade your software. cpqDat4-16(2) ...
cpqDaTapeDrvCleanReq
Compaq Drive Array Tape Drive Cleaning Required. This is an indication of whether the tape drive heads require a cleaning session to occur. If this variable indicates a need to clean the tape heads, then a cleaning tape will need to be inserted and run t ...
cpqDaTapeDrvCleanTapeRepl
Compaq Drive Array Tape Drive Cleaning Tape Replacement. This variable is only applicable to autoloader tape drives. This variable indicates whether the cleaning tape which is inserted in an autoloader needs to be replaced because its cleaning capability ...
cpqDaTapeDrvCleanTapeCount
Compaq Drive Array Tape Drive Cleaning Tape Count. This variable is a count from a tape drive of the number of cleanings done by the tape cleaner last in the drive.
cpqDaTapeDrvLibraryDrive
Compaq Drive Array Tape Drive Library Drive. This variable indicates whether or not the tape drive is part of a tape library. It can be in one of the following states: other(1) Indicates that the instrument agent cannot determine if the tape drive is par ...
cpqDaTapeDrvMagSize
Compaq Tape Physical Drive Magazine Size. This variable indicates the number of tape slots available in the tape autoloader magazine cartridge that is currently loaded into the tape drive. For non-autoloader devices, this value will be -1.
cpqDaTapeDrvHotPlug
Compaq Drive Array Tape Drive Hot Plug Support Status. The following values are defined: other(1) The agent is unable to determine if this drive supports hot plug replacement. hotPlug(2) The drive supports hot plug replacement. nonhotPlug(3) The drive doe ...
cpqDaTapeDrvPlacement
Compaq Drive Array Tape Drive Placement. The following values are defined: other(1) The agent is unable to determine if the tape drive is internal or external to the system chassis. internal(2) The tape drive is located in an internal Proliant system chas ...
cpqDaTapeCountersTable
Compaq Drive Array Tape Counters Table.
cpqDaTapeCountersEntry
Compaq Drive Array Tape Counters Entry.
cpqDaTapeCountersCntlrIndex
Compaq Drive Array Tape Counters Controller Index. This index maps the tape drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqDaTapeCountersBusIndex
Compaq Drive Array Tape Counters Scsi Bus Index. This is the controller SCSI bus to which the tape drive is attached.
cpqDaTapeCountersScsiIdIndex
Compaq Drive Array Tape Counters SCSI Index. This is the SCSI Target Id of the tape drive.
cpqDaTapeCountersLunIndex
Compaq Drive Array Tape Counters Logical Unit Number Index. This is the logical unit number of the tape drive.
cpqDaTapeCountersReWrites
Compaq Tape Device Re-write count. This is the number of times blocks had to be re-written to the device. This value is maintained since the Tape Hardware Interface driver was loaded. Re-write errors may occasionally occur. If this value should rise dra ...
cpqDaTapeCountersReReads
Compaq Tape Device Re-read count. This is the number of times blocks had to be re-read from the device. This value is maintained since the Tape Hardware Interface driver was loaded. Re-read errors may occasionally occur. If this value should rise dramat ...
cpqDaTapeCountersTotalErrors
Compaq Tape Device Total Errors. This is the total number of read/write errors encountered. This value is maintained since the Tape Hardware Interface driver was loaded. Errors may occasionally occur. If this value should rise dramatically, you may need ...
cpqDaTapeCountersTotalUncorrectable
Compaq Tape Device Total Uncorrectable Errors. This is the total number of read and write errors which could not be corrected. This value is maintained since the Tape Hardware Interface driver was loaded. Errors may occasionally occur. If this value sho ...
cpqDaTapeCountersTotalBytes
Compaq Tape Device Total Bytes. This is the number total number of bytes read/written to the tape currently installed in the device. This value is reset whenever a new tape is inserted into the device.
cpqDaTapeLibraryTable
Compaq Drive Array Tape Library Table.
cpqDaTapeLibraryEntry
Compaq Drive Array Tape Library Entry.
cpqDaTapeLibraryCntlrIndex
Compaq Drive Array Tape Library Controller Index. This index maps the tape library back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqDaTapeLibraryScsiBus
Compaq Drive Array Tape Library Scsi Bus. The bus index indicates to which SCSI bus instance on a controller this table entry belongs. The instances start at one and increment for each SCSI bus on a controller.
cpqDaTapeLibraryScsiTarget
Compaq Drive Array Tape Library Scsi Target. The target index indicates to which SCSI ID on a controller SCSI bus this table entry belongs.
cpqDaTapeLibraryScsiLun
Compaq Drive Array Tape Library Scsi Lun. The Lun index indicates to which logical unit on a SCSI ID on a controller SCSI bus this table entry belongs.
cpqDaTapeLibrarySerialNumber
Compaq Drive Array Tape Library Serial Number. This is the unit serial number for the tape library. It can be used for identification purposes.
cpqDaTapeLibraryModel
Compaq Drive Array Tape Library Model. This is the model name of the tape library. It can be used for identification purposes.
cpqDaTapeLibraryFWRev
Compaq Drive Array Tape Library Serial Number. This is firmware revision level of the tape library. It can be used for identification purposes.
cpqDaTapeLibraryStatus
Compaq Drive Array Tape Library Status. The library can be in one of the following states: other(1) The library is in a state other than one of those listed below. ok(2) Indicates that the library is in normal operation mode. No user action is necessary. ...
cpqDaTapeLibraryDoorStatus
Compaq Drive Array Tape Library Door Status. The door can be in one of the following states: other(1) The door is in a state other than one of those listed below. notSupported(2) The door status is not supported by the device. closed(3) The door is closed ...
cpqDaTapeLibraryCondition
Compaq Drive Array Tape Library Condition. This value represents the overall condition of the tape library.
cpqDaTapeLibraryOverallCondition
Compaq Drive Array Tape Library Overall Condition. This value represents the overall condition of the tape library and any associated tape drives.
cpqDaTapeLibraryLastError
Compaq Drive Array Tape Library Last Error. This is the last error returned by the tape library.
cpqDaTapeLibraryStatHours
Compaq Drive Array Tape Library Stat Hours. This is the number of hours of operation for the library.
cpqDaTapeLibraryStatMoves
Compaq Drive Array Tape Library Stat Moves. This is the number of tape moves for the library loader arm.
cpqDaTapeLibraryDriveList
Compaq Drive Array Tape Library Tape Drive List. This is a data structure containing the list of tape drive ids that are present in this library. The format is: field octets contents ===== ====== ======== 1 1 Tape controller slot index 2 ...
cpqDaTrapPkts
The total number of trap packets issued by the drive array enterprise since the instrument agent was loaded.
cpqDaTrapLogMaxSize
The maximum number of entries that will currently be kept in the trap log. If the maximum size has been reached and a new trap occurs the oldest trap will be removed.
cpqDaTrapLogTable
An ordered list of trap log entries (conceptually a queue). The trap log entries will be kept in the order in which they were generated with the most recent trap at index 1 and the oldest trap entry at index trapLogMaxSize. If the maximum number size has ...
cpqDaTrapLogEntry
A description of a trap event.
cpqDaTrapLogIndex
This value uniquely identifies this trapLogEntry at this time. The most recent trap will have an index of 1 and the oldest trap will have an index of trapLogMaxSize. Because of the queue-like nature of the trapLog this particular trap event's index will ...
cpqDaTrapType
The type of the trap event that this entry describes. This number refers to an entry in a list of traps enumerating the possible traps the Drive Array agent may issue.
cpqDaTrapTime
The time of the trap event that this entry describes. The time is given in year (first octet), month, day of month, hour, minute, second (last octet) order. Each octet gives the value in BCD.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now. Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access. The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.