JUNIPER-L2CP-FEATURES-MIB Download
This mib module is for Juniper Networks Proprietory
Layer 2 control protocol (L2CP) features
With the IPHost SNMP tool, you can monitor any SNMP objects of the
JUNIPER-L2CP-FEATURES-MIB.
OID list for JUNIPER-L2CP-FEATURES-MIB
- jnxDot1dStpPortProtectTable
- Defines the jnxDot1dStp Port Table for providing enterprise specific extensions for Root Protect and Loop Protect to the corresponding dot1dStpPortTable entry.
- jnxDot1dStpPortProtectEntry
- Defines an entry in the jnxDot1dStpPortProtectTable. This essentially augments the dot1dStpPortTable with additional objects.
- jnxDot1dStpPortRootProtectEnabled
- A Boolean value set by management indicating whether Root protect functionality is enabled on the port. If TRUE causes the Port not to be selected as Root Port, even it has the best spanning tree priority vector. This parameter should be FALSE by default.
- jnxDot1dStpPortRootProtectState
- Indicates whether the port was prevented from being a root port. This parameter will always return 'no-error (0)' if jnxDot1dStpPortRootProtectEnabled is FALSE.
- jnxDot1dStpPortLoopProtectEnabled
- A Boolean value set by management indicating whether Loop protect functionality is enabled on the port. If TRUE causes the Port not to be selected as Designated Port when the received superior BPDU is aged out. This parameter should be FALSE by default.
- jnxDot1dStpPortLoopProtectState
- Indicates whether a potential Loop was prevented on the port This parameter will always return 'no-error (0)' if jnxDot1dStpPortLoopProtectEnabled is FALSE.
- jnxL2cpBpduProtectPortTable
- Defines a Port Table for BPDU Protect information. This contains only those ports on which BPDU Protect can be configured.
- jnxL2cpBpduProtectPortEntry
- Defines an entry in the jnxL2cpBpduProtectPortTable. A list containing BPDU Protect information for each Port.
- jnxL2cpBpduProtectPortEnabled
- A Boolean value set by management indicating whether BPDU protect functionality is enabled on the port. If TRUE causes the Port to be disabled (link down) upon receipt of a BPDU. This parameter should be FALSE by default.
- jnxL2cpPortBpduError
- Indicates whether a BPDU was received on the port. This parameter will always return 'no-error (0)' if jnxL2cpBpduProtectPortEnabled is FALSE.
- jnxL2cpBpduProtectDisableTimeout
- Returns the value of time (in seconds) after which a port on which BPDU error was detected will be re-enabled. A returned value of 0 indicates that port will not be re-enabled automatically.
- jnxLacpInterfaceName
- Lacp member interface.
- jnxLacpifIndex
- Snmp ifIndex of member interface.
- jnxLacpAggregateInterfaceName
- Lacp Aggregate interface.
- jnxLacpAggregateifIndex
- Snmp ifIndex of Aggregator.
- jnxLacpAggPortActorOperState
- Port actor operational state.
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.
Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access.
The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.