ZYXEL-accessSwitch-MIB
. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables,
their current values and descriptions taken from the
ZYXEL-accessSwitch-MIB
.
OID list for ZYXEL-accessSwitch-MIB
- accessSwitchSystemCurrentStatus
- The sysCurrentStatus is a bit map represented as a sum, therefore, it can represent multiple defects simultaneously. The sysNoDefect should be set if and only if no other flag is set. The various bit positions are: 1 sysNoDefect 2 sysOverHeat 3 sysFa ...
- accessSwitchProblemCause
- The variable is the description of sytsem problem.
- accessSwitchSystemTemperature
- The variable is the current temperature in Celsius of the system.
- accessSwitchFanRpmTable
- A table that contains rpm information about the fans.
- accessSwitchFanRpmEntry
- A list of rpm information for each fan.
- accessSwitchFanRpmIndex
- The identity of the fan.
- accessSwitchFanRpmCurValue
- The current rpm of the fan.
- accessSwitchFanRpmMaxValue
- The maximum rpm ever performed by the fan.
- accessSwitchFanRpmMinValue
- The minimum rpm ever performed by the fan.
- accessSwitchFanRpmLowThresh
- The low threshold of the rpm of the fan. If the current rpm is less than the threshold, the device will initiate the fanRpmLow trap.
- accessSwitchFanRpmDescr
- The description of the fan (e.g. location, function, etc.).
- accessSwitchVoltageTable
- A table that contains voltage information about the system.
- accessSwitchVoltageEntry
- A list of voltage information for each sensor.
- accessSwitchVoltageIndex
- The identity of the sensor.
- accessSwitchVoltageCurValue
- The current voltage detected by the sensor (in milli-voltage).
- accessSwitchVoltageMaxValue
- The maximum voltage ever detected by the sensor (in milli-voltage).
- accessSwitchVoltageMinValue
- The minimum voltage ever detected by the sensor (in milli-voltage).
- accessSwitchVoltageNominalValue
- The nominal voltage which the power should supply (in milli-voltage).
- accessSwitchVoltageLowThresh
- The low threshold of the voltage. If the current voltage is less than the threshold, the device will initiate the voltageLow trap.
- accessSwitchVoltageDescr
- The description of the voltage (e.g. location, nominal value, etc.).
- accessSwitchSysTempTable
- A table that contains temperature information about system.
- accessSwitchSysTempEntry
- A list of temperature information for each sensor.
- accessSwitchSysTempIndex
- The identity of the sensor.
- accessSwitchSysTempCurValue
- The current temperature detected in Celsius by the sensor.
- accessSwitchSysTempMaxValue
- The maximum temperature ever detected in Celsius by the sensor.
- accessSwitchSysTempMinValue
- The minimum temperature ever detected in Celsius by the sensor.
- accessSwitchSysTempHighThresh
- The high threshold of the temperature in Celsius. If the current temperature is higher than the threshold, the device will initiate the overheat trap.
- accessSwitchSysTempDescr
- The description of the temperature sensor (e.g. location, function, etc.).
- accessSwitchMaintenance
- The managed object is for system maintenance. When the EMS wants to trigger the system maitenance operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: config save BIT 2: reset BIT ...
- accessSwitchMaintenancePort
- The port which the maintenance operation should be performed on. The value of 0 means the maintenance should be performed on the system.
- accessSwitchMaxNumOfStaticVlans
- The maximum number of static VLANs which the system supports
- acccessSwitchChassisId
- The chassis Id of the module
- accessSwitchSlotId
- The slot Id of the module
- accessSwitchModuleType
- The type of the module
- accessSwitchFWVersion
- The firmware version of the access switch.
- accessSwitchDriverVersion
- The driver version of the access port in this access switch
- accessSwitchModemCodeVersion
- The modem code version of the access port in this access switch
- accessSwitchDSLConfOps
- The managed object is for xDSL line configuration. When the EMS wants to issue the desired operation, the EMS shall send SNMP-SET message to set the corresponding bit value to be 1. The various bit positions are: BIT 1: enable port BIT 2: disable port BIT ...
- accessSwitchDSLConfTarget
- The managed object is used for identify the target on which the line configuration should be performed. The target is encoded as: Byte 1~4: reserved Byte 5~7: each octet specifies a set of eight ports, with the first octet specifying ports 1 through 8, et ...
- accessSwitchDSLConfProfileName
- The DSL profile name
- accessSwitchDSLConfMode
- The DSL mode. The semantic for each bit is: Bit 1: ADSL, G.lite Bit 2: ADSL, G.dmt Bit 3: ADSL, T1.413 Bit 4: ADSL, Auto
- asPacketForwardingTable
- This table includes the configuration of packet forwarding.
- asPacketForwardingEntry
- An entry in asPacketForwardingTable.
- asPacketForwardingPortList
- The list defines the ports to which the packets will be forwarded.
- asDhcpRelayEnable
- Enable/disable DHCP relay function.
- asDhcpRelayOption82Enable
- Enable/disable the relay agent information option.
- asDhcpRelayOption82Info
- User specific relay agent information.
- asMaxNumOfDhcpServers
- The maximum number of DHCP servers.
- asDhcpServerTable
- A table that contains DHCP server information.
- asDhcpServerEntry
- The entry of DHCP server table.
- asDhcpServerIp
- The IP address of the DHCP server.
- asDhcpServerRowStatus
- The row status of the DHCP server entry.
- asRadiusServerTable
- A table that contains Radius Server information.
- asRadiusServerEntry
- The entry of Radius Server table.
- asRadiusServerIndex
- The identity of the RADIUS server.
- asRadiusServerIp
- The IP address of the Radius Server.
- asRadiusServerPort
- The UDP port of the Radius Server.
- asRadiusSharedSecret
- The shared secret of the Radius Server.
- asRadiusServerRowStatus
- The row status of the Radius Server entry.
- asDot1xEnable
- Enable/disable the 802.1x function.
- asDot1xPortTable
- This table includes the configuration of 802.1x.
- asDot1xPortEntry
- An entry in asDot1xPortTable.
- asDot1xPortEnable
- The option defines if the port enables 802.1x settings.
- asDot1xPortControl
- The configuration defines the 802.1x port control type.
- asDot1xPortReAuthEnable
- The option defines if the port enables 802.1x re-authentication.
- asDot1xPortReAuthPeriod
- The configuration defines the 802.1x re-authentication period for each port.