frUniDlciDcType - Frame Relay Uni Dlci Dc Type

MIBs list

With IPHost Network Monitor you can run simple snmp requests against a Nortel device in your network.

frUniDlciDcType

Frame Relay Uni Dlci Dc Type

This attribute specifies the type of Vc call: permanentMaster, permanentSlave, permanentSlaveWithBackup, permanentBackupSlave. If the value is set to permanentMaster, then a permanent connection will be established between 2 ends. The remote end must be defined as a permanentSlave, permanentBackupSlave or permanentSlaveWithBackup. The Connection cannot be established if the remote end is defined as anything else. The end defined as permanentMaster always initiates the calls. It will attempt to call once per minute. If the value is set to permanentSlave then a permanent connection will be established between 2 ends. The remote end must be defined as a permanentMaster. The Connection cannot be established if the remote end is defined as anything else. The permanentSlave end will attempt to call once per minute. If the value is set to permanentSlaveWithBackup then a permanent connection will be established between the two ends. The remote end must be defined as a permanentMaster. The connection cannot be established if the remote interface end is defined as anything else. The permanentSlaveWithBackup end will attempt to call once per minute. When type is set to permanentSlaveWithBackup connection will be cleared if interface becomes unavailable. This enables a retry of the connection which can be redirected to permanentBackupSlave. If the value is set to permanentBackupSlave then a permanent connection will be established between the 2 ends only if the permanentMaster end is disconnected from the permanentSlaveWithBackup end and a backup call is established by the redirection system. If the permanentSlaveWithBackup interface becomes visible again, the permanentBackupSlave end is disconnected and the permanentSlaveWithBackup end is reconnected to the permanentMaster end. The permanentBackupSlave end does not try to establish pvc call.

Back to Nortel-Magellan-Passport-FrameRelayUniMIB MIB page.

IPHost Network monitor allows you to monitor frUniDlciDcType on Allied Telesis device via the SNMP protocol. Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring Nortel speech servers right now.

Easy monitoring of frUniDlciDcType with IPHost tools

MIBs list