rfc1382

rfc1382 Download

MIBs list

With the IPHost SNMP tool, you can monitor any SNMP objects of the rfc1382-x25packet . You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the rfc1382-x25packet .

OID list for rfc1382

x25AdmnTable
This table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have corresponding objects in the x25OperTable. This table contains the values as last set by the administrator. ...
x25AdmnEntry
Entries of x25AdmnTable.
x25AdmnIndex
The ifIndex value for the X.25 Interface.
x25AdmnInterfaceMode
Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation.
x25AdmnMaxActiveCircuits
The maximum number of circuits this PLE can support; including PVCs.
x25AdmnPacketSequencing
The modulus of the packet sequence number space.
x25AdmnRestartTimer
The T20 restart timer in milliseconds.
x25AdmnCallTimer
The T21 Call timer in milliseconds.
x25AdmnResetTimer
The T22 Reset timer in milliseconds.
x25AdmnClearTimer
The T23 Clear timer in milliseconds.
x25AdmnWindowTimer
The T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use.
x25AdmnDataRxmtTimer
The T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
x25AdmnInterruptTimer
The T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use.
x25AdmnRejectTimer
The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
x25AdmnRegistrationRequestTimer
The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
x25AdmnMinimumRecallTimer
Minimum time interval between unsuccessful call attempts in milliseconds.
x25AdmnRestartCount
The R20 restart retransmission count.
x25AdmnResetCount
The r22 Reset retransmission count.
x25AdmnClearCount
The r23 Clear retransmission count.
x25AdmnDataRxmtCount
The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use.
x25AdmnRejectCount
The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use.
x25AdmnRegistrationRequestCount
The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use.
x25AdmnNumberPVCs
The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
x25AdmnDefCallParamId
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE.
x25AdmnLocalAddress
The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
x25AdmnProtocolVersionSupported
Identifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
x25OperTable
The operation parameters in use by the X.25 PLE.
x25OperEntry
Entries of x25OperTable.
x25OperIndex
The ifIndex value for the X.25 interface.
x25OperInterfaceMode
Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place.
x25OperMaxActiveCircuits
Maximum number of circuits this PLE can support.
x25OperPacketSequencing
The modulus of the packet sequence number space.
x25OperRestartTimer
The T20 restart timer in milliseconds.
x25OperCallTimer
The T21 Call timer in milliseconds.
x25OperResetTimer
The T22 Reset timer in milliseconds.
x25OperClearTimer
The T23 Clear timer in milliseconds.
x25OperWindowTimer
The T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use.
x25OperDataRxmtTimer
The T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
x25OperInterruptTimer
The T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used.
x25OperRejectTimer
The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
x25OperRegistrationRequestTimer
The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
x25OperMinimumRecallTimer
Minimum time interval between unsuccessful call attempts in milliseconds.
x25OperRestartCount
The R20 restart retransmission count.
x25OperResetCount
The r22 Reset retransmission count.
x25OperClearCount
The r23 Clear retransmission count.
x25OperDataRxmtCount
The R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use.
x25OperRejectCount
The R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use.
x25OperRegistrationRequestCount
The R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use.
x25OperNumberPVCs
The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
x25OperDefCallParamId
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE.
x25OperLocalAddress
The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
x25OperDataLinkId
This identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE.
x25OperProtocolVersionSupported
Identifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
x25StatTable
Statistics information about this X.25 PLE.
x25StatEntry
Entries of the x25StatTable.
x25StatIndex
The ifIndex value for the X.25 interface.
x25StatInCalls
The number of incoming calls received.
x25StatInCallRefusals
The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select.
x25StatInProviderInitiatedClears
The number of clear requests with a cause code other than DTE initiated.
x25StatInRemotelyInitiatedResets
The number of reset requests received with cause code DTE initiated.
x25StatInProviderInitiatedResets
The number of reset requests received with cause code other than DTE initiated.
x25StatInRestarts
The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection wit ...
x25StatInDataPackets
The number of data packets received.
x25StatInAccusedOfProtocolErrors
The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets.
x25StatInInterrupts
The number of interrupt packets received by the PLE or over the PVC/VC.
x25StatOutCallAttempts
The number of calls attempted.
x25StatOutCallFailures
The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select.
x25StatOutInterrupts
The number of interrupt packets send by the PLE or over the PVC/VC.
x25StatOutDataPackets
The number of data packets sent by this PLE.
x25StatOutgoingCircuits
The number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
x25StatIncomingCircuits
The number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs.
x25StatTwowayCircuits
The number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
x25StatRestartTimeouts
The number of times the T20 restart timer expired.
x25StatCallTimeouts
The number of times the T21 call timer expired.
x25StatResetTimeouts
The number of times the T22 reset timer expired.
x25StatClearTimeouts
The number of times the T23 clear timer expired.
x25StatDataRxmtTimeouts
The number of times the T25 data timer expired.
x25StatInterruptTimeouts
The number of times the T26 interrupt timer expired.
x25StatRetryCountExceededs
The number of times a retry counter was exhausted.
x25StatClearCountExceededs
The number of times the R23 clear count was exceeded.
x25ChannelTable
These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE.
x25ChannelEntry
Entries of x25ChannelTable.
x25ChannelIndex
The ifIndex value for the X.25 Interface.
x25ChannelLIC
Lowest Incoming channel.
x25ChannelHIC
Highest Incoming channel. A value of zero indicates no channels in this range.
x25ChannelLTC
Lowest Two-way channel.
x25ChannelHTC
Highest Two-way channel. A value of zero indicates no channels in this range.
x25ChannelLOC
Lowest outgoing channel.
x25ChannelHOC
Highest outgoing channel. A value of zero indicates no channels in this range.
x25CircuitTable
These objects contain general information about a specific circuit of an X.25 PLE.
x25CircuitEntry
Entries of x25CircuitTable.
x25CircuitIndex
The ifIndex value for the X.25 Interface.
x25CircuitChannel
The channel number for this circuit.
x25CircuitStatus
This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start c ...
x25CircuitEstablishTime
The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was ab ...
x25CircuitDirection
The direction of the call that established this circuit.
x25CircuitInOctets
The number of octets of user data delivered to upper layer.
x25CircuitInPdus
The number of PDUs received for this circuit.
x25CircuitInRemotelyInitiatedResets
The number of Resets received for this circuit with cause code of DTE initiated.
x25CircuitInProviderInitiatedResets
The number of Resets received for this circuit with cause code other than DTE initiated.
x25CircuitInInterrupts
The number of interrupt packets received for this circuit.
x25CircuitOutOctets
The number of octets of user data sent for this circuit.
x25CircuitOutPdus
The number of PDUs sent for this circuit.
x25CircuitOutInterrupts
The number of interrupt packets sent on this circuit.
x25CircuitDataRetransmissionTimeouts
The number of times the T25 data retransmission timer expired for this circuit.
x25CircuitResetTimeouts
The number of times the T22 reset timer expired for this circuit.
x25CircuitInterruptTimeouts
The number of times the T26 Interrupt timer expired for this circuit.
x25CircuitCallParamId
This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than prop ...
x25CircuitCalledDteAddress
For incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packet. This will be zero length for PVCs.
x25CircuitCallingDteAddress
For incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation packet. This will be zero length for PVCs.
x25CircuitOriginallyCalledAddress
For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address ...
x25CircuitDescr
A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using ...
x25ClearedCircuitEntriesRequested
The requested number of entries for the agent to keep in the x25ClearedCircuit table.
x25ClearedCircuitEntriesGranted
The actual number of entries the agent will keep in the x25ClearedCircuit Table.
x25ClearedCircuitTable
A table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet contains a clearing cause other than DTE Originated or a Diagnostic code field other than Higher Lay ...
x25ClearedCircuitEntry
Information about a cleared circuit.
x25ClearedCircuitIndex
An index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each new entry added to the table. Upon reaching one, the index will reset to 2147483647. Because th ...
x25ClearedCircuitPleIndex
The value of ifIndex for the PLE which cleared the circuit that created the entry.
x25ClearedCircuitTimeEstablished
The value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit.
x25ClearedCircuitTimeCleared
The value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely initiated clears, this will be the time when the clear indication was received.
x25ClearedCircuitChannel
The channel number for the circuit that was cleared.
x25ClearedCircuitClearingCause
The Clearing Cause from the clear request or clear indication packet that cleared the circuit.
x25ClearedCircuitDiagnosticCode
The Diagnostic Code from the clear request or clear indication packet that cleared the circuit.
x25ClearedCircuitInPdus
The number of PDUs received on the circuit.
x25ClearedCircuitOutPdus
The number of PDUs transmitted on the circuit.
x25ClearedCircuitCalledAddress
The called address from the cleared circuit.
x25ClearedCircuitCallingAddress
The calling address from the cleared circuit.
x25ClearedCircuitClearFacilities
The facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present.
x25CallParmTable
These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any ...
x25CallParmEntry
Entries of x25CallParmTable.
x25CallParmIndex
A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this ta ...
x25CallParmStatus
The status of this call parameter entry. See RFC 1271 for details of usage.
x25CallParmRefCount
The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such obj ...
x25CallParmInPacketSize
The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128.
x25CallParmOutPacketSize
The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128.
x25CallParmInWindowSize
The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
x25CallParmOutWindowSize
The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
x25CallParmAcceptReverseCharging
An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is only used for the PLE default and indicates the PLE will never accept reverse charging. A value ...
x25CallParmProposeReverseCharging
An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local.
x25CallParmFastSelect
Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect. A value of noFastSelect or noRestrictedFastResponse indicates a circuit may not use fast sel ...
x25CallParmInThruPutClasSize
The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class.
x25CallParmOutThruPutClasSize
The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class.
x25CallParmCug
The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE de ...
x25CallParmCugoa
The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters ...
x25CallParmBcug
The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an ...
x25CallParmNui
The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default paramet ...
x25CallParmChargingInfo
The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility.
x25CallParmRpoa
The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may no ...
x25CallParmTrnstDly
The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be use ...
x25CallParmCallingExt
The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length ...
x25CallParmCalledExt
The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length ...
x25CallParmInMinThuPutCls
The minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
x25CallParmOutMinThuPutCls
The minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
x25CallParmEndTrnsDly
The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE de ...
x25CallParmPriority
The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length.
x25CallParmProtection
A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contain ...
x25CallParmExptData
The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default.
x25CallParmUserData
The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE ha ...
x25CallParmCallingNetworkFacilities
The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means ...
x25CallParmCalledNetworkFacilities
The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means ...

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now. Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access. The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.

MIBs list