rfc1382 Download
With the IPHost SNMP tool, you can monitor any SNMP objects of the
rfc1382-x25packet
. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables,
their current values and descriptions taken from the
rfc1382-x25packet
.
OID list for rfc1382
- x25AdmnTable
- This table contains the administratively set configuration parameters for an X.25 Packet Level Entity (PLE). Most of the objects in this table have corresponding objects in the x25OperTable. This table contains the values as last set by the administrator. ...
- x25AdmnEntry
- Entries of x25AdmnTable.
- x25AdmnIndex
- The ifIndex value for the X.25 Interface.
- x25AdmnInterfaceMode
- Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the mode will be determined by XID negotiation.
- x25AdmnMaxActiveCircuits
- The maximum number of circuits this PLE can support; including PVCs.
- x25AdmnPacketSequencing
- The modulus of the packet sequence number space.
- x25AdmnRestartTimer
- The T20 restart timer in milliseconds.
- x25AdmnCallTimer
- The T21 Call timer in milliseconds.
- x25AdmnResetTimer
- The T22 Reset timer in milliseconds.
- x25AdmnClearTimer
- The T23 Clear timer in milliseconds.
- x25AdmnWindowTimer
- The T24 window status transmission timer in milliseconds. A value of 2147483647 indicates no window timer in use.
- x25AdmnDataRxmtTimer
- The T25 data retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
- x25AdmnInterruptTimer
- The T26 interrupt timer in milliseconds. A value of 2147483647 indicates no interrupt timer in use.
- x25AdmnRejectTimer
- The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
- x25AdmnRegistrationRequestTimer
- The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
- x25AdmnMinimumRecallTimer
- Minimum time interval between unsuccessful call attempts in milliseconds.
- x25AdmnRestartCount
- The R20 restart retransmission count.
- x25AdmnResetCount
- The r22 Reset retransmission count.
- x25AdmnClearCount
- The r23 Clear retransmission count.
- x25AdmnDataRxmtCount
- The R25 Data retransmission count. This value is irrelevant if the x25AdmnDataRxmtTimer indicates no timer in use.
- x25AdmnRejectCount
- The R27 reject retransmission count. This value is irrelevant if the x25AdmnRejectTimer indicates no timer in use.
- x25AdmnRegistrationRequestCount
- The R28 Registration retransmission Count. This value is irrelevant if the x25AdmnRegistrationRequestTimer indicates no timer in use.
- x25AdmnNumberPVCs
- The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
- x25AdmnDefCallParamId
- This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the default call parameters for this PLE.
- x25AdmnLocalAddress
- The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
- x25AdmnProtocolVersionSupported
- Identifies the version of the X.25 protocol this interface should support. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
- x25OperTable
- The operation parameters in use by the X.25 PLE.
- x25OperEntry
- Entries of x25OperTable.
- x25OperIndex
- The ifIndex value for the X.25 interface.
- x25OperInterfaceMode
- Identifies DCE/DTE mode in which the interface operates. A value of dxe indicates the role will be determined by XID negotiation at the Link Layer and that negotiation has not yet taken place.
- x25OperMaxActiveCircuits
- Maximum number of circuits this PLE can support.
- x25OperPacketSequencing
- The modulus of the packet sequence number space.
- x25OperRestartTimer
- The T20 restart timer in milliseconds.
- x25OperCallTimer
- The T21 Call timer in milliseconds.
- x25OperResetTimer
- The T22 Reset timer in milliseconds.
- x25OperClearTimer
- The T23 Clear timer in milliseconds.
- x25OperWindowTimer
- The T24 window status transmission timer milliseconds. A value of 2147483647 indicates no window timer in use.
- x25OperDataRxmtTimer
- The T25 Data Retransmission timer in milliseconds. A value of 2147483647 indicates no data retransmission timer in use.
- x25OperInterruptTimer
- The T26 Interrupt timer in milliseconds. A value of 2147483647 indicates interrupts are not being used.
- x25OperRejectTimer
- The T27 Reject retransmission timer in milliseconds. A value of 2147483647 indicates no reject timer in use.
- x25OperRegistrationRequestTimer
- The T28 registration timer in milliseconds. A value of 2147483647 indicates no registration timer in use.
- x25OperMinimumRecallTimer
- Minimum time interval between unsuccessful call attempts in milliseconds.
- x25OperRestartCount
- The R20 restart retransmission count.
- x25OperResetCount
- The r22 Reset retransmission count.
- x25OperClearCount
- The r23 Clear retransmission count.
- x25OperDataRxmtCount
- The R25 Data retransmission count. This value is undefined if the x25OperDataRxmtTimer indicates no timer in use.
- x25OperRejectCount
- The R27 reject retransmission count. This value is undefined if the x25OperRejectTimer indicates no timer in use.
- x25OperRegistrationRequestCount
- The R28 Registration retransmission Count. This value is undefined if the x25OperREgistrationRequestTimer indicates no timer in use.
- x25OperNumberPVCs
- The number of PVC configured for this PLE. The PVCs use channel numbers from 1 to this number.
- x25OperDefCallParamId
- This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable that contains the default call parameters for this PLE.
- x25OperLocalAddress
- The local address for this PLE subnetwork. A zero length address maybe returned by PLEs that only support PVCs.
- x25OperDataLinkId
- This identifies the instance of the index object in the first table of the most device specific MIB for the interface used by this PLE.
- x25OperProtocolVersionSupported
- Identifies the version of the X.25 protocol this interface supports. Object identifiers for common versions are defined below in the x25ProtocolVersion subtree.
- x25StatTable
- Statistics information about this X.25 PLE.
- x25StatEntry
- Entries of the x25StatTable.
- x25StatIndex
- The ifIndex value for the X.25 interface.
- x25StatInCalls
- The number of incoming calls received.
- x25StatInCallRefusals
- The number of incoming calls refused. This includes calls refused by the PLE and by higher layers. This also includes calls cleared because of restricted fast select.
- x25StatInProviderInitiatedClears
- The number of clear requests with a cause code other than DTE initiated.
- x25StatInRemotelyInitiatedResets
- The number of reset requests received with cause code DTE initiated.
- x25StatInProviderInitiatedResets
- The number of reset requests received with cause code other than DTE initiated.
- x25StatInRestarts
- The number of remotely initiated (including provider initiated) restarts experienced by the PLE excluding the restart associated with bringing up the PLE interface. This only counts restarts received when the PLE already has an established connection wit ...
- x25StatInDataPackets
- The number of data packets received.
- x25StatInAccusedOfProtocolErrors
- The number of packets received containing a procedure error cause code. These include clear, reset, restart, or diagnostic packets.
- x25StatInInterrupts
- The number of interrupt packets received by the PLE or over the PVC/VC.
- x25StatOutCallAttempts
- The number of calls attempted.
- x25StatOutCallFailures
- The number of call attempts which failed. This includes calls that were cleared because of restrictive fast select.
- x25StatOutInterrupts
- The number of interrupt packets send by the PLE or over the PVC/VC.
- x25StatOutDataPackets
- The number of data packets sent by this PLE.
- x25StatOutgoingCircuits
- The number of active outgoing circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
- x25StatIncomingCircuits
- The number of active Incoming Circuits. This includes call indications received but not yet acknowledged. This does not count PVCs.
- x25StatTwowayCircuits
- The number of active two-way Circuits. This includes call requests sent but not yet confirmed. This does not count PVCs.
- x25StatRestartTimeouts
- The number of times the T20 restart timer expired.
- x25StatCallTimeouts
- The number of times the T21 call timer expired.
- x25StatResetTimeouts
- The number of times the T22 reset timer expired.
- x25StatClearTimeouts
- The number of times the T23 clear timer expired.
- x25StatDataRxmtTimeouts
- The number of times the T25 data timer expired.
- x25StatInterruptTimeouts
- The number of times the T26 interrupt timer expired.
- x25StatRetryCountExceededs
- The number of times a retry counter was exhausted.
- x25StatClearCountExceededs
- The number of times the R23 clear count was exceeded.
- x25ChannelTable
- These objects contain information about the channel number configuration in an X.25 PLE. These values are the configured values. changes in these values after the interfaces has started may not be reflected in the operating PLE.
- x25ChannelEntry
- Entries of x25ChannelTable.
- x25ChannelIndex
- The ifIndex value for the X.25 Interface.
- x25ChannelLIC
- Lowest Incoming channel.
- x25ChannelHIC
- Highest Incoming channel. A value of zero indicates no channels in this range.
- x25ChannelLTC
- Lowest Two-way channel.
- x25ChannelHTC
- Highest Two-way channel. A value of zero indicates no channels in this range.
- x25ChannelLOC
- Lowest outgoing channel.
- x25ChannelHOC
- Highest outgoing channel. A value of zero indicates no channels in this range.
- x25CircuitTable
- These objects contain general information about a specific circuit of an X.25 PLE.
- x25CircuitEntry
- Entries of x25CircuitTable.
- x25CircuitIndex
- The ifIndex value for the X.25 Interface.
- x25CircuitChannel
- The channel number for this circuit.
- x25CircuitStatus
- This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start c ...
- x25CircuitEstablishTime
- The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was ab ...
- x25CircuitDirection
- The direction of the call that established this circuit.
- x25CircuitInOctets
- The number of octets of user data delivered to upper layer.
- x25CircuitInPdus
- The number of PDUs received for this circuit.
- x25CircuitInRemotelyInitiatedResets
- The number of Resets received for this circuit with cause code of DTE initiated.
- x25CircuitInProviderInitiatedResets
- The number of Resets received for this circuit with cause code other than DTE initiated.
- x25CircuitInInterrupts
- The number of interrupt packets received for this circuit.
- x25CircuitOutOctets
- The number of octets of user data sent for this circuit.
- x25CircuitOutPdus
- The number of PDUs sent for this circuit.
- x25CircuitOutInterrupts
- The number of interrupt packets sent on this circuit.
- x25CircuitDataRetransmissionTimeouts
- The number of times the T25 data retransmission timer expired for this circuit.
- x25CircuitResetTimeouts
- The number of times the T22 reset timer expired for this circuit.
- x25CircuitInterruptTimeouts
- The number of times the T26 Interrupt timer expired for this circuit.
- x25CircuitCallParamId
- This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than prop ...
- x25CircuitCalledDteAddress
- For incoming calls, this is the called address from the call indication packet. For outgoing calls, this is the called address from the call confirmation packet. This will be zero length for PVCs.
- x25CircuitCallingDteAddress
- For incoming calls, this is the calling address from the call indication packet. For outgoing calls, this is the calling address from the call confirmation packet. This will be zero length for PVCs.
- x25CircuitOriginallyCalledAddress
- For incoming calls, this is the address in the call Redirection or Call Deflection Notification facility if the call was deflected or redirected, otherwise it will be called address from the call indication packet. For outgoing calls, this is the address ...
- x25CircuitDescr
- A descriptive string associated with this circuit. This provides a place for the agent to supply any descriptive information it knows about the use or owner of the circuit. The agent may return the process identifier and user name for the process using ...
- x25ClearedCircuitEntriesRequested
- The requested number of entries for the agent to keep in the x25ClearedCircuit table.
- x25ClearedCircuitEntriesGranted
- The actual number of entries the agent will keep in the x25ClearedCircuit Table.
- x25ClearedCircuitTable
- A table of entries about closed circuits. Entries must be made in this table whenever circuits are closed and the close request or close indication packet contains a clearing cause other than DTE Originated or a Diagnostic code field other than Higher Lay ...
- x25ClearedCircuitEntry
- Information about a cleared circuit.
- x25ClearedCircuitIndex
- An index that uniquely distinguishes one entry in the clearedCircuitTable from another. This index will start at 2147483647 and will decrease by one for each new entry added to the table. Upon reaching one, the index will reset to 2147483647. Because th ...
- x25ClearedCircuitPleIndex
- The value of ifIndex for the PLE which cleared the circuit that created the entry.
- x25ClearedCircuitTimeEstablished
- The value of sysUpTime when the circuit was established. This will be the same value that was in the x25CircuitEstablishTime for the circuit.
- x25ClearedCircuitTimeCleared
- The value of sysUpTime when the circuit was cleared. For locally initiated clears, this will be the time when the clear confirmation was received. For remotely initiated clears, this will be the time when the clear indication was received.
- x25ClearedCircuitChannel
- The channel number for the circuit that was cleared.
- x25ClearedCircuitClearingCause
- The Clearing Cause from the clear request or clear indication packet that cleared the circuit.
- x25ClearedCircuitDiagnosticCode
- The Diagnostic Code from the clear request or clear indication packet that cleared the circuit.
- x25ClearedCircuitInPdus
- The number of PDUs received on the circuit.
- x25ClearedCircuitOutPdus
- The number of PDUs transmitted on the circuit.
- x25ClearedCircuitCalledAddress
- The called address from the cleared circuit.
- x25ClearedCircuitCallingAddress
- The calling address from the cleared circuit.
- x25ClearedCircuitClearFacilities
- The facilities field from the clear request or clear indication packet that cleared the circuit. A size of zero indicates no facilities were present.
- x25CallParmTable
- These objects contain the parameters that can be varied between X.25 calls. The entries in this table are independent of the PLE. There exists only one of these tables for the entire system. The indexes for the entries are independent of any PLE or any ...
- x25CallParmEntry
- Entries of x25CallParmTable.
- x25CallParmIndex
- A value that distinguishes this entry from another entry. Entries in this table are referenced from other objects which identify call parameters. It is impossible to know which other objects in the MIB reference entries in the table by looking at this ta ...
- x25CallParmStatus
- The status of this call parameter entry. See RFC 1271 for details of usage.
- x25CallParmRefCount
- The number of references know by a management station to exist to this set of call parameters. This is the number of other objects that have returned a value of, and will return a value of, the index for this set of call parameters. Examples of such obj ...
- x25CallParmInPacketSize
- The maximum receive packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE means use a default size of 128.
- x25CallParmOutPacketSize
- The maximum transmit packet size in octets for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use a default size of 128.
- x25CallParmInWindowSize
- The receive window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
- x25CallParmOutWindowSize
- The transmit window size for a circuit. A size of zero for a circuit means use the PLE default size. A size of zero for the PLE default means use 2.
- x25CallParmAcceptReverseCharging
- An enumeration defining if the PLE will accept or refuse charges. A value of default for a circuit means use the PLE default value. A value of neverAccept is only used for the PLE default and indicates the PLE will never accept reverse charging. A value ...
- x25CallParmProposeReverseCharging
- An enumeration defining if the PLE should propose reverse or local charging. The value of default for a circuit means use the PLE default. The value of default for the PLE default means use local.
- x25CallParmFastSelect
- Expresses preference for use of fast select facility. The value of default for a circuit is the PLE default. A value of default for the PLE means noFastSelect. A value of noFastSelect or noRestrictedFastResponse indicates a circuit may not use fast sel ...
- x25CallParmInThruPutClasSize
- The incoming throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means tcNone. A value of tcNone means do not negotiate throughtput class.
- x25CallParmOutThruPutClasSize
- The outgoing throughput class to negotiate. A value of tcDefault for a circuit means use the PLE default. A value of tcDefault for the PLE default means use tcNone. A value of tcNone means do not negotiate throughtput class.
- x25CallParmCug
- The Closed User Group to specify. This consists of two or four octets containing the characters 0 through 9. A zero length string indicates no facility requested. A string length of three containing the characters DEF for a circuit means use the PLE de ...
- x25CallParmCugoa
- The Closed User Group with Outgoing Access to specify. This consists of two or four octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameters ...
- x25CallParmBcug
- The Bilateral Closed User Group to specify. This consists of two octets containing the characters 0 through 9. A string length of three containing the characters DEF for a circuit means use the PLE default (the PLE default parameter may not reference an ...
- x25CallParmNui
- The Network User Identifier facility. This is binary value to be included immediately after the length field. The PLE will supply the length octet. A zero length string indicates no facility requested. This value is ignored for the PLE default paramet ...
- x25CallParmChargingInfo
- The charging Information facility. A value of default for a circuit means use the PLE default. The value of default for the default PLE parameters means use noFacility. The value of noFacility means do not include a facility.
- x25CallParmRpoa
- The RPOA facility. The octet string contains n * 4 sequences of the characters 0-9 to specify a facility with n entries. The octet string containing the 3 characters DEF for a circuit specifies use of the PLE default (the entry for the PLE default may no ...
- x25CallParmTrnstDly
- The Transit Delay Selection and Indication value. A value of 65536 indicates no facility requested. A value of 65537 for a circuit means use the PLE default (the PLE default parameters entry may not use the value 65537). The value 65535 may only be use ...
- x25CallParmCallingExt
- The Calling Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length ...
- x25CallParmCalledExt
- The Called Extension facility. This contains one of the following: A sequence of hex digits with the value to be put in the facility. These digits will be converted to binary by the agent and put in the facility. These octets do not include the length ...
- x25CallParmInMinThuPutCls
- The minimum input throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
- x25CallParmOutMinThuPutCls
- The minimum output throughput Class. A value of 16 for a circuit means use the PLE default (the PLE parameters entry may not use this value). A value of 17 indicates no facility requested.
- x25CallParmEndTrnsDly
- The End-to-End Transit Delay to negotiate. An octet string of length 2, 4, or 6 contains the facility encoded as specified in ISO/IEC 8208 section 15.3.2.4. An octet string of length 3 containing the three character DEF for a circuit means use the PLE de ...
- x25CallParmPriority
- The priority facility to negotiate. The octet string encoded as specified in ISO/IEC 8208 section 15.3.2.5. A zero length string indicates no facility requested. The entry for the PLE default parameters must be zero length.
- x25CallParmProtection
- A string contains the following: A hex string containing the value for the protection facility. This will be converted from hex to the octets actually in the packet by the agent. The agent will supply the length field and the length octet is not contain ...
- x25CallParmExptData
- The Expedited Data facility to negotiate. A value of default for a circuit means use the PLE default value. The entry for the PLE default parameters may not have the value default.
- x25CallParmUserData
- The call user data as placed in the packet. A zero length string indicates no call user data. If both the circuit call parameters and the PLE default have call user data defined, the data from the circuit call parameters will be used. If only the PLE ha ...
- x25CallParmCallingNetworkFacilities
- The calling network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means ...
- x25CallParmCalledNetworkFacilities
- The called network facilities. The facilities are encoded here exactly as encoded in the call packet. These facilities do not include the marker facility code. A zero length string in the entry for the parameter to use when establishing a circuit means ...
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.
Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access.
The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.