rfc1604 Download
With the IPHost SNMP tool, you can monitor any SNMP objects of the
rfc1604-frnetserv-mib
. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables,
their current values and descriptions taken from the
rfc1604-frnetserv-mib
.
OID list for rfc1604
- frLportTable
- The Frame Relay Logical Port Information table.
- frLportEntry
- An entry in the Frame Relay Logical Port Information table.
- frLportNumPlan
- The value of this object identifies the network address numbering plan for this UNI/NNI logical port. The network address is the object ifPhysAddress. The value none implies that there is no ifPhysAddress. The SNMP proxy-agent will return an octet string ...
- frLportContact
- The value of this object identifies the network contact for this UNI/NNI logical port.
- frLportLocation
- The value of this object identifies the Frame Relay network location for this UNI/NNI logical port.
- frLportType
- The value of this object identifies the type of network interface for this logical port.
- frLportAddrDLCILen
- The value of this object identifies the Q.922 Address field length and DLCI length for this UNI/NNI logical port.
- frLportVCSigProtocol
- The value of this object identifies the Local In-Channel Signaling Protocol that is used for this frame relay UNI/NNI logical port.
- frLportVCSigPointer
- The value of this object is used as a pointer to the table that contains the Local In-Channel Signaling Protocol parameters and errors for this UNI/NNI logical port. See the Frame Relay Management VC Signaling Parameters and Errors Group.
- frMgtVCSigTable
- The Frame Relay Management VC Signaling Parameters and Errors table.
- frMgtVCSigEntry
- An entry in the Frame Relay Management VC Signaling Parameters Errors table.
- frMgtVCSigProced
- The value of this object identifies the Local In-Channel Signaling Procedure that is used for this UNI/NNI logical port. The UNI/NNI logical port can be performing only user-to-network network-side procedures or bidirectional procedures.
- frMgtVCSigUserN391
- The value of this object identifies the User-side N391 full status polling cycle value for this UNI/NNI logical port. If the logical port is not performing user-side procedures, then this value is equal to noSuchName. This object applies to Q.933 Annex A ...
- frMgtVCSigUserN392
- The value of this object identifies the User-side N392 error threshold value for this UNI/NNI logical port. If the logical port is not performing user-side procedures, then this value is equal to noSuchName. This object applies to Q.933 Annex A and T1.61 ...
- frMgtVCSigUserN393
- The value of this object identifies the User-side N393 monitored events count value for this UNI/NNI logical port. If the logical port is not performing user-side procedures, then this value is equal to noSuchName. This object applies to Q.933 Annex A an ...
- frMgtVCSigUserT391
- The value of this object identifies the User-side T391 link integrity verification polling timer value for this UNI/NNI logical port. If the logical port is not performing user-side procedures, then this value is equal to noSuchName. This object applies ...
- frMgtVCSigNetN392
- The value of this object identifies the Network- side N392 error threshold value (nN2 for LMI) for this UNI/NNI logical port. If the logical port is not performing network-side procedures, then this value is equal to noSuchName. This object applies to Q. ...
- frMgtVCSigNetN393
- The value of this object identifies the Network- side N393 monitored events count value (nN3 for LMI) for this UNI/NNI logical port. If the logical port is not performing network-side procedures, then this value is equal to noSuchName. This object applie ...
- frMgtVCSigNetT392
- The value of this object identifies the Network- side T392 polling verification timer value (nT2 for LMI) for this UNI/NNI logical port. If the logical port is not performing network-side procedures, then this value is equal to noSuchName. This object a ...
- frMgtVCSigNetnN4
- The value of this object identifies the Network- side nN4 maximum status enquires received value for this UNI/NNI logical port. If the logical port is not performing network-side procedures or is not performing LMI procedures, then this value is equal to ...
- frMgtVCSigNetnT3
- The value of this object identifies the Network- side nT3 timer (for nN4 status enquires received) value for this UNI/NNI logical port. If the logical port is not performing network-side procedures or is not performing LMI procedures, then this value is ...
- frMgtVCSigUserLinkRelErrors
- The number of user-side local in-channel signaling link reliability errors (i.e., non- receipt of Status/Status Enquiry messages or invalid sequence numbers in a Link Integrity Verification Information Element) for this UNI/NNI logical port. If the logic ...
- frMgtVCSigUserProtErrors
- The number of user-side local in-channel signaling protocol errors (i.e., protocol discriminator, message type, call reference, and mandatory information element errors) for this UNI/NNI logical port. If the logical port is not performing user-side proce ...
- frMgtVCSigUserChanInactive
- The number of times the user-side channel was declared inactive (i.e., N392 errors in N393 events) for this UNI/NNI logical port. If the logical port is not performing user-side procedures, then this value is equal to noSuchName.
- frMgtVCSigNetLinkRelErrors
- The number of network-side local in-channel signaling link reliability errors (i.e., non- receipt of Status/Status Enquiry messages or invalid sequence numbers in a Link Integrity Verification Information Element) for this UNI/NNI logical port. If the lo ...
- frMgtVCSigNetProtErrors
- The number of network-side local in-channel signaling protocol errors (i.e., protocol discriminator, message type, call reference, and mandatory information element errors) for this UNI/NNI logical port. If the logical port is not performing network-side ...
- frMgtVCSigNetChanInactive
- The number of times the network-side channel was declared inactive (i.e., N392 errors in N393 events) for this UNI/NNI logical port. If the logical port is not performing network-side procedures, then this value is equal to noSuchName.
- frPVCEndptTable
- The Frame Relay PVC End-Point table. This table is used to model a PVC end-point. This table contains the traffic parameters and statistics for a PVC end-point.
- frPVCEndptEntry
- An entry in the Frame Relay PVC Endpoint table.
- frPVCEndptDLCIIndex
- The value of this object is equal to the DLCI value for this PVC end-point.
- frPVCEndptInMaxFrameSize
- The value of this object is the size in octets of the largest frame relay information field for this PVC end-point in the ingress direction (into the frame relay network). The value of frPVCEndptInMaxFrameSize must be less than or equal to the correspond ...
- frPVCEndptInBc
- The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC end-point in the ingress direction (into the frame relay network).
- frPVCEndptInBe
- The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC end-point in the ingress direction (into the frame relay network).
- frPVCEndptInCIR
- The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC end- point in the ingress direction (into the frame relay network).
- frPVCEndptOutMaxFrameSize
- The value of this object is the size in octets of the largest frame relay information field for this PVC end-point in the egress direction (out of the frame relay network). The value of frPVCEndptOutMaxFrameSize must be less than or equal to the correspo ...
- frPVCEndptOutBc
- The value of this object is equal to the committed burst size (Bc) parameter (measured in bits) for this PVC end-point in the egress direction (out of the frame relay network).
- frPVCEndptOutBe
- The value of this object is equal to the excess burst size (Be) parameter (measured in bits) for this PVC end-point in the egress direction (out of the frame relay network).
- frPVCEndptOutCIR
- The value of this object is equal to the committed information rate (CIR) parameter (measured in bits per second) for this PVC end- point in the egress direction (out of the frame relay network).
- frPVCEndptConnectIdentifier
- This object is used to associate PVC end-points as being part of one PVC segment connection. This value of this object is equal to the value of frPVCConnectIndex, which is used as one of the indices into the frPVCConnectTable. The value of this object i ...
- frPVCEndptRowStatus
- This object is used to create new rows in this table, modify existing rows, and to delete existing rows. To create a new PVC, the entries for the PVC segment end-points in the frPVCEndptTable must first be created. Next, the frPVCConnectTable is used to ...
- frPVCEndptRcvdSigStatus
- The value of this object identifies the PVC status received via the local in-channel signaling procedures for this PVC end-point. This object is only pertinent for interfaces that perform the bidirectional procedures. For user-to-network network side pr ...
- frPVCEndptInFrames
- The number of frames received by the network (ingress) for this PVC end-point. This includes any frames discarded by the network due to submitting more than Bc + Be data or due to any network congestion recovery procedures.
- frPVCEndptOutFrames
- The number of frames sent by the network (egress) regardless of whether they are Bc or Be frames for this PVC end-point.
- frPVCEndptInDEFrames
- The number of frames received by the network (ingress) with the DE bit set to (1) for this PVC end-point.
- frPVCEndptInExcessFrames
- The number of frames received by the network (ingress) for this PVC end-point which were treated as excess traffic. Frames which are sent to the network with DE set to zero are treated as excess when more than Bc bits are submitted to the network during ...
- frPVCEndptOutExcessFrames
- The number of frames sent by the network (egress) for this PVC end-point which were treated as excess traffic. (The DE bit may be set to one.)
- frPVCEndptInDiscards
- The number of frames received by the the network (ingress) that were discarded due to traffic enforcement for this PVC end-point.
- frPVCEndptInOctets
- The number of octets received by the network (ingress) for this PVC end-point. This counter should only count octets from the beginning of the frame relay header field to the end of user data. If the network supporting Frame Relay can not count octets, t ...
- frPVCEndptOutOctets
- The number of octets sent by the network (egress) for this PVC end-point. This counter should only count octets from the beginning of the frame relay header field to the end of user data. If the network supporting Frame Relay can not count octets, then ...
- frPVCConnectIndexValue
- This object contains an appropriate value to be used for frPVCConnectIndex when creating entries in the frPVCConnectTable. The value 0 indicates that no unassigned entries are available. To obtain the frPVCConnectIndex value for a new entry, the manager ...
- frPVCConnectTable
- The Frame Relay PVC Connect table. A bi- directional PVC segment is modeled as one entry in this table.
- frPVCConnectEntry
- An entry in the Frame Relay PVC Connect table. This entry is used to model a PVC segment in two directions.
- frPVCConnectIndex
- The value of this object is equal to the frPVCConnectIndexValue obtained to uniquely identify this PVC segment connection.
- frPVCConnectLowIfIndex
- The value of this object is equal to MIB II's ifIndex value of the UNI/NNI logical port for this PVC segment. The term low implies that this PVC segment end-point has the numerically lower ifIndex value than the connected/associated PVC segment end-point ...
- frPVCConnectLowDLCIIndex
- The value of this object is equal to the DLCI value for this end-point of the PVC segment. If the value is equal to zero, then this endpoint of the PVC segment is not a Frame Relay connection.
- frPVCConnectHighIfIndex
- The value of this object is equal to MIB II's ifIndex value for the UNI/NNI logical port for this PVC segment. The term high implies that this PVC segment end-point has the numerically higher ifIndex value than the connected/associated PVC segment end-po ...
- frPVCConnectHighDLCIIndex
- The value of this object is equal to the egress DLCI value for this end-point of the PVC segment.
- frPVCConnectAdminStatus
- The value of this object identifies the desired administrative status of this bi-directional PVC segment. The active state means the PVC segment is currently operational; the inactive state means the PVC segment is currently not operational; the testing ...
- frPVCConnectL2hOperStatus
- The value of this object identifies the current operational status of the PVC segment connection in one direction; (i.e., in the low to high direction). The active state means it is currently operational; the inactive state means it is currently not oper ...
- frPVCConnectH2lOperStatus
- The value of this object identifies the current operational status of the PVC segment connection in one direction; (i.e., in the high to low direction). The active state means it is currently operational; the inactive state means it is currently not oper ...
- frPVCConnectL2hLastChange
- The value of MIB II's sysUpTime object at the time this PVC segment entered its current operational state in the low to high direction. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a ze ...
- frPVCConnectH2lLastChange
- The value of MIB II's sysUpTime object at the time this PVC segment entered its current operational state in the high to low direction. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a ze ...
- frPVCConnectRowStatus
- The status of this entry in the frPVCConnectTable. This variable is used to create new connections for the PVC end-points and to change existing connections of the PVC end- points. This object must be initially set to `createAndWait'. In this state, th ...
- frAccountPVCTable
- The Frame Relay Accounting PVC table. This table is used to perform accounting on a PVC segment end-point basis.
- frAccountPVCEntry
- An entry in the Frame Relay Accounting PVC table.
- frAccountPVCDLCIIndex
- The value of this object is equal to the DLCI value for this PVC segment end-point.
- frAccountPVCSegmentSize
- The value of this object is equal to the Segment Size for this PVC segment end-point.
- frAccountPVCInSegments
- The value of this object is equal to the number of segments received by this PVC segment end- point.
- frAccountPVCOutSegments
- The value of this object is equal to the number of segments sent by this PVC segment end-point.
- frAccountLportTable
- The Frame Relay Accounting Logical Port table. This table is used to perform accounting on a UNI/NNI Logical Port basis.
- frAccountLportEntry
- An entry in the Frame Relay Accounting Logical Port table.
- frAccountLportSegmentSize
- The value of this object is equal to the Segment Size for this UNI/NNI logical port.
- frAccountLportInSegments
- The value of this object is equal to the number of segments received by this UNI/NNI logical port.
- frAccountLportOutSegments
- The value of this object is equal to the number of segments sent by this UNI/NNI logical port.
- frnetservLportGroup
- A collection of objects providing information applicable to a Frame Relay Logical Port.
- frnetservMgtVCSigGroup
- A collection of objects providing information applicable to the Local In-Channel Signaling Procedures used for a UNI/NNI logical port.
- frnetservPVCEndptGroup
- A collection of objects providing information application to a Frame Relay PVC end-point.
- frnetservPVCConnectGroup
- A collection of objects providing information applicable to a Frame Relay PVC connection.
- frnetservAccountPVCGroup
- A collection of objects providing accounting information application to a Frame Relay PVC end-point.
- frnetservAccountLportGroup
- A collection of objects providing accounting information application to a Frame Relay logical port.
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.
Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access.
The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.