OIDs - Controller Status monitor
The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for controller status
- Compaq Console Management Controller Trap Status
- cpqCmcTrapStatus 1.3.6.1.4.1.232.153.2.2.2.3.2.1.2 (defined in CPQCMC)
Enable or disable trap receiver - Compaq Console Management Controller Status Temp1
- cpqCmcStatusTemp1 1.3.6.1.4.1.232.153.2.2.4.1 (defined in CPQCMC)
The status of temperature 1, see thresholds of temperature 1: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) error, sensor disconnected - Compaq Console Management Controller Status Temp2
- cpqCmcStatusTemp2 1.3.6.1.4.1.232.153.2.2.4.2 (defined in CPQCMC)
The status of temperature 2, see thresholds of temperature 2: (2) temperature normal (3) temperature exceeds warning threshold (4) temperature exceeds max. threshold (5) temperature drops under min. threshold (6) no sensor connected, not available (7) error, sensor disconnected - Compaq Console Management Controller Status Fan1
- cpqCmcStatusFan1 1.3.6.1.4.1.232.153.2.2.4.3 (defined in CPQCMC)
The status of fan 1: (2) fan is switched off by temperature sensor 1 (3) fan is switched on by temperature sensor 1 (4) fan is switched off by Manual Control (cpqCmcSetFan1) (5) fan is switched on by Manual Control (cpqCmcSetFan1) (6) fan is switched off because of smoke alarm (7) fan is switched off because door is open (8) no fan (9) fan error, current monitoring - Compaq Console Management Controller Status Fan2
- cpqCmcStatusFan2 1.3.6.1.4.1.232.153.2.2.4.4 (defined in CPQCMC)
The status of fan 2: (2) fan is switched off by temperature sensor 2 (3) fan is switched on by temperature sensor 2 (4) fan is switched off by Manual Control (cpqCmcSetFan2) (5) fan is switched on by Manual Control (cpqCmcSetFan2) (6) fan is switched off because of smoke alarm (7) fan is switched off because door is open (8) no fan (9) fan error, current monitoring - Compaq Console Management Controller Status Voltage
- cpqCmcStatusVoltage 1.3.6.1.4.1.232.153.2.2.4.5 (defined in CPQCMC)
The voltage-status, see thresholds of power supply: (2) voltage normal (3) voltage exceeds max. threshold (4) voltage drops under min. threshold (5) no power connected - Compaq Console Management Controller Status Humidity
- cpqCmcStatusHumidity 1.3.6.1.4.1.232.153.2.2.4.6 (defined in CPQCMC)
The humidity-status, see thresholds of humidity: (2) humidity normal (3) humidity exceeds max. threshold (4) humidity drops under min. threshold (5) no sensor connected, not available (6) error, sensor disconnected - Compaq Console Management Controller Status Input1
- cpqCmcStatusInput1 1.3.6.1.4.1.232.153.2.2.4.7 (defined in CPQCMC)
The status of door/sidepanel 1, closed (2), open (3) or no sensor connected (4) - Compaq Console Management Controller Status Input2
- cpqCmcStatusInput2 1.3.6.1.4.1.232.153.2.2.4.8 (defined in CPQCMC)
The status of door/sidepanel 2, closed (2), open (3) or no sensor connected (4) - Compaq Console Management Controller Status Input3
- cpqCmcStatusInput3 1.3.6.1.4.1.232.153.2.2.4.9 (defined in CPQCMC)
The status of door/sidepanel 3, closed (2), open (3) or no sensor connected (4) - Compaq Console Management Controller Status Input4
- cpqCmcStatusInput4 1.3.6.1.4.1.232.153.2.2.4.10 (defined in CPQCMC)
The status of door/sidepanel 4, closed (2), open (3) or no sensor connected (4) - Compaq Console Management Controller Status Lock1 Lock
- cpqCmcStatusLock1Lock 1.3.6.1.4.1.232.153.2.2.4.11 (defined in CPQCMC)
The status of door locking 1 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is unlocked by Network Management (5) Door locking-device is not activated, door is unlocked because of Smoke alarm (6) Door is unlocked from remote-signal (7) Door locking-device is not activated, door is unlocked because of Power Fail of locking device (8) Door locking-device is not activated, door is unlocked because of low Battery of locking device (9) Door locking-device is not activated, door is unlocked because of Network Fail (10)Door locking-device is not activated, door is unlocked because of connection fail, no connection locking device <-> CMC (11)Door locking-device is ready to lock, lock will be activated after doors are closed (12)Door locking-device is activated but door is not locked, alarm (13)Configuration error, association door to locking-device missing (14)Lock not installed - Compaq Console Management Controller Status Lock2 Lock
- cpqCmcStatusLock2Lock 1.3.6.1.4.1.232.153.2.2.4.12 (defined in CPQCMC)
The status of door locking 2 (2) Door locking-device is activated, door is locked (3) Door locking-device is not activated, door is unlocked by Network Management (4) Door locking-device is not activated for x sec, time see cpqCmcSetupLock1Time, door is unlocked by Network Management (5) Door locking-device is not activated, door is unlocked because of Smoke alarm (6) Door is unlocked from remote-signal (7) Door locking-device is not activated, door is unlocked because of Power Fail of locking device (8) Door locking-device is not activated, door is unlocked because of low Battery of locking device (9) Door locking-device is not activated, door is unlocked because of Network Fail (10)Door locking-device is not activated, door is unlocked because of connection fail, no connection locking device <-> CMC (11)Door locking-device is ready to lock, lock will be activated after doors are closed (12)Door locking-device is activated but door is not locked, alarm (13)Configuration error, association door to locking-device missing (14)Lock not installed - Compaq Console Management Controller Status Smoke
- cpqCmcStatusSmoke 1.3.6.1.4.1.232.153.2.2.4.13 (defined in CPQCMC)
Status smoke-sensor, OK (2), smoke detected (3) or no sensor connected (4) - Compaq Console Management Controller Status Shock
- cpqCmcStatusShock 1.3.6.1.4.1.232.153.2.2.4.14 (defined in CPQCMC)
Status Shock sensor, OK (2), shock detected (3) or no sensor connected (4) - Compaq Console Management Controller Status Aux1
- cpqCmcStatusAux1 1.3.6.1.4.1.232.153.2.2.4.15 (defined in CPQCMC)
Status aux. digital input - Compaq Console Management Controller Status Aux2
- cpqCmcStatusAux2 1.3.6.1.4.1.232.153.2.2.4.16 (defined in CPQCMC)
Status aux. digital input - Compaq Console Management Controller Status Alarm1
- cpqCmcStatusAlarm1 1.3.6.1.4.1.232.153.2.2.4.17 (defined in CPQCMC)
Status of alarm 1, see cmpCmcsetAlarm1. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm1Description. - Compaq Console Management Controller Status Alarm2
- cpqCmcStatusAlarm2 1.3.6.1.4.1.232.153.2.2.4.18 (defined in CPQCMC)
Status of alarm 2, see cmpCmcsetAlarm2. This alarm can be set from the Network management system. A descriptional text for this alarm can be set in cpqCmcSetupAlarm2Description. - Compaq Console Management Controller Status Lock1 Device
- cpqCmcStatusLock1Dev 1.3.6.1.4.1.232.153.2.2.4.19 (defined in CPQCMC)
The status of door-locking device 1 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (7) Connection CMC->door locking device lost (8) Lock not installed - Compaq Console Management Controller Status Lock2 Device
- cpqCmcStatusLock2Dev 1.3.6.1.4.1.232.153.2.2.4.20 (defined in CPQCMC)
The status of door-locking device 2 (2) OK (3) Power fail of door locking-device (4) Low Battery of door locking-device (5) Battery of door locking device needs to be replaced (6) Battery missing, insert all batteries (6) Connection CMC->door locking device lost (7) Lock not installed - Compaq Console Management Controller Status Access
- cpqCmcStatusAccess 1.3.6.1.4.1.232.153.2.2.5.1 (defined in CPQCMC)
Status access, for future use - Compaq CR3500 RAID Controller Log Drive Status
- cpqCrLogDrvStatus 1.3.6.1.4.1.232.141.2.3.1.1.4 (defined in CPQCR)
RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduced (3) Indicates that the RAIDset is operating in a degraded or reduced state. One or more of the physical disks which make up the RAIDset are either missing or failed, but the RAIDset can continue to operate without data loss. Failed (4) Indicates that the RAIDset is not operational. Reconstructing (5) Indicates that the RAIDset is regenerating a failed physical drive's data onto a replacement drive that is part of the RAIDset. All user data remains available during the reconstruction process, but some performance reduction may occur when a request requires access to the device being reconstructed. Initializing (6) Indicates that the controller is writing its file structure onto the RAIDset's member devices. - Compaq CR3500 RAID Controller Spare Status
- cpqCrSpareStatus 1.3.6.1.4.1.232.141.2.4.1.1.3 (defined in CPQCR)
Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Hot Spare(5) The drive attached to this channel is kept spinning whenever the controller is powered up and it is to be automatically brought online to replace a failed drive. Warm Spare(6) The drive attached to this channel is not spun up until a disk in the array fails and it is automatically brought online to replace a failed drive. Adding Spare(9) The drive is in the process of becoming a spare drive. - Compaq CR3500 RAID Controller Physical Drive Status
- cpqCrPhyDrvStatus 1.3.6.1.4.1.232.141.2.5.1.1.6 (defined in CPQCR)
Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status: Offline (3) The drive attached to this channel is not a member of the RAID set. Online (4) The drive attached to this channel is a fully functional member of this RAID set. Creating (5) The drive is currently being created as part of a RAID set. Rebuilding (6) The drive is currently being rebuilt. Formatting (8) The drive is currently being formatted - Compaq CR3500 RAID Controller EMU Board Temperature Status
- cpqCrEMUBoardTemperatureStatus 1.3.6.1.4.1.232.141.2.7.1 (defined in CPQCR)
Environmental Monitoring Unit (EMU) Board Temperature status. The System Board Temperature status as determined by the EMU is: Not Installed (2) The board temperature can not be detected in the unit. Normal (3) The board temperature detected by the EMU is normal. Below Normal (4) The board temperature detected by the EMU is below normal. Above Normal (5) The board temperature detected by the EMU is above normal. Far Below Normal (6) The board temperature detected by the EMU is far below normal. Far Above Normal (7) The board temperature detected by the EMU is far above normal. Back To Normal (8) The board temperature detected by the EMU has returned to normal. - Compaq CR3500 RAID Controller EMU Enclosure Temperature Status
- cpqCrEMUEnclosureTemperatureStatus 1.3.6.1.4.1.232.141.2.7.2 (defined in CPQCR)
Environmental Monitoring Unit (EMU) Enclosure Temperature status. The Enclosure Housing Temperature status as determined by the EMU is: Not Installed (2) The enclosure temperature can not be detected in the unit. Normal (3) The enclosure temperature detected by the EMU is normal. Below Normal (4) The enclosure temperature detected by the EMU is below normal. Above Normal (5) The enclosure temperature detected by the EMU is above normal. Far Below Normal (6) The enclosure temperature detected by the EMU is far below normal. Far Above Normal (7) The enclosure temperature detected by the EMU is far above normal. Back To Normal (8) The enclosure temperature detected by the EMU has returned to normal. - Compaq CR3500 RAID Controller EMU Fan Status
- cpqCrEMUFanStatus 1.3.6.1.4.1.232.141.2.7.6 (defined in CPQCR)
Primary enclosure fan status. The primary enclosure fan status is: OK (2) Status is normal. Critical (3) Fan has failed. Unknown (4) Information unavailable. - Compaq CR3500 RAID Controller EMU Power Supply Status
- cpqCrEMUPowerSupplyStatus 1.3.6.1.4.1.232.141.2.7.8 (defined in CPQCR)
Primary enclosure power supply status. The primary enclosure power supply status is: OK (2) Status is normal. Critical (3) Power supply is installed and marked as failed. Not Installed (4) One of the redundant power supplies has been removed. Unknown (5) Information unavailable. - Compaq CR3500 RAID Controller EMU Temperature Status
- cpqCrEMUTemperatureStatus 1.3.6.1.4.1.232.141.2.7.10 (defined in CPQCR)
Primary enclosure temperature status. The primary enclosure temperature status is: OK (2) Status is normal. Critical (3) Controller temperature sensor has detected a critical temperature condition in the primary enclosure. Non-critical (4) Controller temperature sensor has detected an abnormal temperature condition in the primary enclosure. Unknown (5) Information unavailable. - Compaq CR3500 RAID Controller Expansion Cabinet Power Supply Status
- cpqCrExpCabPowerSupplyStatus 1.3.6.1.4.1.232.141.2.8.1 (defined in CPQCR)
Expansion Cabinet power supply status. The expansion cabinet power supply status is: OK (2) Status is normal. Either redundant power supplies are installed and reporting no error or a single power supply is installed. Non-Critical (3) Redundant power supplies are installed and reporting a fault. Unknown (5) Information unavailable. - Compaq CR3500 RAID Controller Expansion Cabinet Fan Status
- cpqCrExpCabFanStatus 1.3.6.1.4.1.232.141.2.8.2 (defined in CPQCR)
Expansion Cabinet fan status. The expansion cabinet fan status is: OK (2) Status is normal. One or more fans is installed and no error is reported. Non-Critical (4) Fan degraded condition. One or more fans are reporting an error or only one fan is installed. Not Installed (5) Fan valid bit not set. Unknown (6) Information unavailable. - Compaq CR3500 RAID Controller Expansion Cabinet Temperature Status
- cpqCrExpCabTemperatureStatus 1.3.6.1.4.1.232.141.2.8.3 (defined in CPQCR)
Expansion Cabinet temperature status. The expansion cabinet temperature status is: OK (2) Status is normal. Critical (3) Critical temperature condition reported. Non-Critical (4) Warning temperature condition reported. Not Installed (5) Temperature valid bit not set. Unknown (6) Information unavailable. - Compaq CR3500 RAID Controller Partition Status
- cpqCrPartitionStatus 1.3.6.1.4.1.232.141.2.9.1.1.4 (defined in CPQCR)
Logical Drive Status. The logical drive can be in one of the following states: Good (2) Indicates that the logical drive is fully operational. Reduced (3) Indicates that the logical drive is operating in a degraded or reduced state. One or more of the physical disks which make up the logical drive are either missing or failed, but the logical drive can continue to operate without data loss. Failed (4) Indicates that the logical drive is not operational. Reconstructing (5) Indicates that the logical drive is regenerating a failed physical drive's data onto a replacement drive that is part of the logical drive. All user data remains available during the reconstruction process, but some performance reduction may occur when a request requires access to the device being reconstructed. Initializing (6) Indicates that the controller is writing its file structure onto the logical drive's member devices.