OIDs - Fan Status monitor
The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for fan status
- environmental monitor Fan Status Table
- apEnvMonFanStatusTable 1.3.6.1.4.1.9148.3.3.1.4.1 (defined in ACMEPACKET-ENVMON-MIB)
The table of fan status maintained by the environmental monitor. - environmental monitor Fan Status Entry
- apEnvMonFanStatusEntry 1.3.6.1.4.1.9148.3.3.1.4.1.1 (defined in ACMEPACKET-ENVMON-MIB)
An entry in the fan status table, representing the status of the associated fan maintained by the environmental monitor. - environmental monitor Fan Status Index
- apEnvMonFanStatusIndex 1.3.6.1.4.1.9148.3.3.1.4.1.1.1 (defined in ACMEPACKET-ENVMON-MIB)
Unique index for the fan being instrumented. This index is for SNMP purposes only. - environmental monitor Fan Status Type
- apEnvMonFanStatusType 1.3.6.1.4.1.9148.3.3.1.4.1.1.2 (defined in ACMEPACKET-ENVMON-MIB)
The entity part type from which the fan value is from. The left and right at the base when one faces the front of the SD. Next-generation products contain replaceable fans contained in chassis slots. - environmental monitor Fan Status Description
- apEnvMonFanStatusDescr 1.3.6.1.4.1.9148.3.3.1.4.1.1.3 (defined in ACMEPACKET-ENVMON-MIB)
Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. - environmental monitor Fan Status Value
- apEnvMonFanStatusValue 1.3.6.1.4.1.9148.3.3.1.4.1.1.4 (defined in ACMEPACKET-ENVMON-MIB)
The current percentage measurement of the fan speed. - Compaq CR3500 RAID Controller EMU Fan Status
- cpqCrEMUFanStatus 1.3.6.1.4.1.232.141.2.7.6 (defined in CPQCR)
Primary enclosure fan status. The primary enclosure fan status is: OK (2) Status is normal. Critical (3) Fan has failed. Unknown (4) Information unavailable. - Compaq CR3500 RAID Controller Expansion Cabinet Fan Status
- cpqCrExpCabFanStatus 1.3.6.1.4.1.232.141.2.8.2 (defined in CPQCR)
Expansion Cabinet fan status. The expansion cabinet fan status is: OK (2) Status is normal. One or more fans is installed and no error is reported. Non-Critical (4) Fan degraded condition. One or more fans are reporting an error or only one fan is installed. Not Installed (5) Fan valid bit not set. Unknown (6) Information unavailable. - Compaq Server Health Thermal System Fan Status
- cpqHeThermalSystemFanStatus 1.3.6.1.4.1.232.6.2.6.4 (defined in CPQHLTH)
The status of the fan(s) in the system. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) All fans are operating properly. degraded(3) A non-required fan is not operating properly. failed(4) A required fan is not operating properly. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the failed(4) condition occurs. - Compaq Server Health Thermal Cpu Fan Status
- cpqHeThermalCpuFanStatus 1.3.6.1.4.1.232.6.2.6.5 (defined in CPQHLTH)
The status of the processor fan(s) in the system. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) All fans are operating properly. failed(4) A fan is not operating properly. The system will be shutdown if the failed(4) condition occurs. - Compaq Server Health Thermal Fan Status
- cpqHeThermalFanStatus 1.3.6.1.4.1.232.6.2.6.6.1.5 (defined in CPQHLTH)
This specifies if the fan described is operating properly. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) The fan is operating properly. failed(4) The fan is not operating properly. - Compaq Storage System Box Fan Status
- cpqSsBoxFanStatus 1.3.6.1.4.1.232.8.2.1.1.7 (defined in CPQSTSYS)
Compaq Drive Box Fan Status. This is the current status of the fans in the drive box. This value will be one of the following: other(1) Fan monitoring is not supported by this system or it is not supported by the driver. ok(2) All fans are working normally. failed(3) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. noFan(4) This unit does not support fan monitoring. degraded(5) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. - Compaq Storage System Fan Module Status
- cpqSsFanModuleStatus 1.3.6.1.4.1.232.8.2.2.4.1.3 (defined in CPQSTSYS)
Compaq Storage System Fan Module Status. The following values are defined: other(1) The agent is unable to determine if this storage system fan module is installed. notInstalled(3) The fan module is not installed. ok(2) The fan module is installed and operating normally. degraded(4) The fan module degraded. failed(5) The fan module is failed. Replace the fan module. - Compaq Storage System Backplane Fan Status
- cpqSsBackplaneFanStatus 1.3.6.1.4.1.232.8.2.2.6.1.10 (defined in CPQSTSYS)
Compaq Storage System Backplane Fan Status. This is the current status of the fans in the storage system. This value will be one of the following: other(1) The agent is unable to determine if this storage system has fan monitoring. notInstalled(2) This unit does not support fan monitoring. ok(3) All fans are working normally. degraded(4) At least one storage system fan has failed, but there is still sufficient cooling capacity to allow the system to continue. The fan should be replaced. failed(5) One or more storage system fans have failed. The fan(s) should be replaced immediately to avoid hardware damage. notSupported(6) The storage system does not support reporting fan status through this backplane. The fan status is reported through the first backplane on this storage system.