OID list for port flow
- a3 Com Qos Flow Class Port Start
- a3ComQosFlowClassPortStart 1.3.6.1.4.1.43.29.4.21.1.2.1.9 (defined in A3COM-SWITCHING-SYSTEMS-QOS-MIB)
The starting range of ports associated with this class. - a3 Com Qos Flow Class Port End
- a3ComQosFlowClassPortEnd 1.3.6.1.4.1.43.29.4.21.1.2.1.10 (defined in A3COM-SWITCHING-SYSTEMS-QOS-MIB)
The finishing range of ports associated with this class. - Character Port In Flow Type
- charPortInFlowType 1.3.6.1.2.1.19.2.1.9 (defined in rfc1316)
The port's type of input flow control. 'none' indicates no flow control at this level or below. 'xonXoff' indicates software flow control by recognizing XON and XOFF characters. 'hardware' indicates flow control delegated to the lower level, for example a parallel port. 'ctsRts' and 'dsrDtr' are specific to RS-232-like ports. Although not architecturally pure, they are included here for simplicity's sake. - Character Port In Flow State
- charPortInFlowState 1.3.6.1.2.1.19.2.1.11 (defined in rfc1316)
The current operational state of input flow control on the port. 'none' indicates not applicable. 'unknown' indicates this level does not know. 'stop' indicates flow not allowed. 'go' indicates flow allowed. - Character Port In Flow Type
- charPortInFlowType 1.3.6.1.2.1.19.2.1.9 (defined in rfc1658)
The port's type of input flow control. 'none' indicates no flow control at this level or below. 'xonXoff' indicates software flow control by recognizing XON and XOFF characters. 'hardware' indicates flow control delegated to the lower level, for example a parallel port. 'ctsRts' and 'dsrDtr' are specific to RS-232-like ports. Although not architecturally pure, they are included here for simplicity's sake. - Character Port In Flow State
- charPortInFlowState 1.3.6.1.2.1.19.2.1.11 (defined in rfc1658)
The current operational state of input flow control on the port. 'none' indicates not applicable. 'unknown' indicates this level does not know. 'stop' indicates flow not allowed. 'go' indicates flow allowed. - rs232 Port In Flow Type
- rs232PortInFlowType 1.3.6.1.2.1.10.33.2.1.7 (defined in rfc1659)
The port's type of input flow control. 'none' indicates no flow control at this level. 'ctsRts' and 'dsrDtr' indicate use of the indicated hardware signals. - rs232 Port Out Flow Type
- rs232PortOutFlowType 1.3.6.1.2.1.10.33.2.1.8 (defined in rfc1659)
The port's type of output flow control. 'none' indicates no flow control at this level. 'ctsRts' and 'dsrDtr' indicate use of the indicated hardware signals. - els100 Port Flow Control Enable
- els100PortFlowControlEnable 1.3.6.1.4.1.52.1011.2.1.10 (defined in ctels100-ng-mib)
The state of flow control operation of the port, either enable or disable. - sfps L4 CDR Active Flow Source Protocol Port
- sfpsL4CDRActiveFlowSourceProtocolPort 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.7 (defined in ctron-sfps-l4ss-mib)
If this is a Layer 4 flow, this value indicates the protocol port number of the source of the flow. Otherwise, this field is zero. - sfps L4 CDR Active Flow Destination Protocol Port
- sfpsL4CDRActiveFlowDestProtocolPort 1.3.6.1.4.1.52.4.2.4.2.6.2.4.1.13 (defined in ctron-sfps-l4ss-mib)
If this is a Layer 4 flow, this value indicates the protocol port number of the destination of the flow. Otherwise, this field is zero. - l3 Flow Port Of Entry
- l3FlowPortOfEntry 1.3.6.1.4.1.52.2501.1.3.1.1.3 (defined in ctron-ssr-l3-mib)
The physical port in the chassis/shelf from which this flow enters the switch. - l3 Flow Destination Port
- l3FlowDstPort 1.3.6.1.4.1.52.2501.1.3.1.1.9 (defined in ctron-ssr-l3-mib)
The destination UDP/TCP port for this flow. Official port numbers are defined in ftp://ftp.isi.edu/in-notes/iana/assignments/port-numbers - Switch Port Management Flow Control Admin
- swPortMgtFlowCtrlAdmin 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.5 (defined in els100-s24tx2m-mib)
(1) Flow control mechanism is enabled. If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (3) Flow control mechanism is backPressure. When the port is in fullDuplex mode this flow control mechanism will not function. (4) Flow control mechanism is IEEE 802.3x flow control. When the port is in halfDuplex mode this flow control mechanism will not function. hundredBaseTX and thousandBaseSX port can be set as: enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4). hundredBaseFX port can be set as: enabled(1), disabled(2), backPressure(3). The actual flow control mechanism is used given by swPortMgtFlowCtrlInUse. - Switch Port Management Flow Control In Use
- swPortMgtFlowCtrlInUse 1.3.6.1.4.1.52.3.9.1.10.7.2.1.1.6 (defined in els100-s24tx2m-mib)
(1) BackPressure flow control mechanism is used. (2) IEEE 802.3 flow control mechanism is used. (3) Flow control mechanism is disabled. - port X25 Admin Flow Control Negotiation
- portX25AdminFlowCtrlNeg 1.3.6.1.4.1.173.7.3.1.5.1.2 (defined in netlink-specific-mib)
A flag which if set, permits negotiation of the flow control parameters on a per call basis. If N is selected, the default packet and window sizes will be used. If Y is selected, the packet or window size in a call packet (up to the configured Max Packet Size or Max Window Size) is used. - port X25 Operation Flow Control Negotiation
- portX25OperFlowCtrlNeg 1.3.6.1.4.1.173.7.3.1.6.1.2 (defined in netlink-specific-mib)
A flag which if set, permits negotiation of the flow control parameters on a per call basis. If N is selected, the default packet and window sizes will be used. If Y is selected, the packet or window size in a call packet (up to the configured Max Packet Size or Max Window Size) is used. - port Flow Control Configuration
- portFlowCtrlCfg 1.3.6.1.4.1.52.4.12.30.1.2.1.1.5 (defined in v2h124-24-mib)
If the port type is hundredBaseTX or thousandBaseSX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, the port uses IEEE 802.3x flow control mechanism. If the port type is hundredBaseFX: When the port is operating in halfDuplex mode, the port uses backPressure flow control mechanism. When the port is operating in fullDuplex mode, Flow control mechanism will not function. (2) Flow control mechanism is disabled. (3) Flow control mechanism is backPressure. when the port is in fullDuplex mode.This flow control mechanism will not function. (4) Flow control mechanism is IEEE 802.3x flow control. when the port is in halfDuplex mode.This flow control mechanism will not function. hundredBaseTX and thousandBaseSX port can be set as: enabled(1), disabled(2), backPressure(3), dot3xFlowControl(4). hundredBaseFX port can be set as: enabled(1), disabled(2), backPressure(3). The actual flow control mechanism is used given by portFlowCtrlStatus. - port Flow Control Status
- portFlowCtrlStatus 1.3.6.1.4.1.52.4.12.30.1.2.1.1.9 (defined in v2h124-24-mib)
(3) IEEE 802.3 flow control machanism is used. (4) Flow control mechanism is disabled. If the entry represents a trunk and the member ports have been inconsistently configured then this value is error(1). - Enterasys Radius Snooping Flow Server Port Number
- etsysRadiusSnoopingFlowServerPortNumber 1.3.6.1.4.1.5624.1.2.62.2.1.4.1.1.6 (defined in enterasys-radius-snooping-mib)
The destination UDP port number (0-65535) the client will use to send RADIUS requests to the server and the source UDP port number (0-65535) the server will use to send RADIUS responses to the client. Maintaining the value of etsysRadiusSnoopingFlowServerPortNumber for all active(1) entries across agent reboots is REQUIRED. - agent Port Dot 3 Flow Control Mode
- agentPortDot3FlowControlMode 1.3.6.1.4.1.14179.1.2.12.1.14 (defined in AIRESPACE-SWITCHING-MIB)
Config flowcontrol allows you to enable or disable 802.3x flow control for this port. This value applies to only full-duplex mode ports. - Cisco Access Control List QoS Ip Flow Source Port
- caqIpFlowSrcPort 1.3.6.1.4.1.9.9.179.1.7.4.1.7 (defined in CISCO-CATOS-ACL-QOS-MIB)
Indicates the source port number of this logged IP flow when its protocol field is TCP or UDP. The value of this object is -1 if the flow is not UDP or TCP traffic. - Cisco Access Control List QoS Ip Flow Destination Port
- caqIpFlowDestPort 1.3.6.1.4.1.9.9.179.1.7.4.1.9 (defined in CISCO-CATOS-ACL-QOS-MIB)
Indicates the destination port number of this logged IP flow when its protocol field is TCP or UDP. The value of this object is -1 if the flow is not UDP or TCP traffic.