Power Supply Status monitor - SNMP OIDs

MIBs list

OIDs - Power Supply Status monitor

The objects described here can be monitored with the IPHost Network Monitor. You can start SNMP monitoring using free 30-day trial version of IPHost right now.

OID list for power supply status

Sys Power Supply Status Table
a3ComSysPowerSupplyStatusTable 1.3.6.1.4.1.43.29.4.4.2 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
A list of power supply status entries.
Sys Power Supply Status Entry
a3ComSysPowerSupplyStatusEntry 1.3.6.1.4.1.43.29.4.4.2.1 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
A power supply status entry contains information about a particular power supply.
Sys Power Supply Status Index
a3ComSysPowerSupplyStatusIndex 1.3.6.1.4.1.43.29.4.4.2.1.1 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
The unique index of the power supply identified by this entry.
Sys Power Supply Status
a3ComSysPowerSupplyStatus 1.3.6.1.4.1.43.29.4.4.2.1.2 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
This object represents the power supply status. The value is a sum. It initially takes on the value 0, then for each type which is active, 2 raised to a power is added to the sum. The powers are according to the following table. For the 6000 Backbone Aggregator an over temp for power supply 1 and power supply 2 will be reported as a power supply 1 Over Temperature Failure, and a fan failure will be reported as a power supply 2 Over Temperature Failure. Failure Type Power AC Failure 0 Plus 5 Failure 1 Plus 12 Failure 2 Over Temperature Failure 3 Power Supply Inserted 4 Power Supply Extracted 5
Sys Power Supply Status Supported
a3ComSysPowerSupplyStatusSupported 1.3.6.1.4.1.43.29.4.4.2.1.3 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
This object represents the various power supply status types which are supported. The value is a sum. It initially takes on the value 0, then for each type which is supported, 2 raised to a power is added to the sum. The powers are according to the following table: Failure Type Power AC Failure 0 Plus 5 Failure 1 Plus 12 Failure 2 Over Temperature Failure 3 Power Supply Inserted 4 Power Supply Extracted 5 This object used in conjunction with the a3ComSysPowerSupplyStatus object for a given power supply provide a complete picture of the status of the power supply.
environmental monitor Power Supply Status Table
apEnvMonPowerSupplyStatusTable 1.3.6.1.4.1.9148.3.3.1.5.1 (defined in ACMEPACKET-ENVMON-MIB)
The table of power supply status maintained by the environmental monitor card.
environmental monitor Power Supply Status Entry
apEnvMonPowerSupplyStatusEntry 1.3.6.1.4.1.9148.3.3.1.5.1.1 (defined in ACMEPACKET-ENVMON-MIB)
An entry in the power supply status table, representing the status of the associated power supply maintained by the environmental monitor card.
environmental monitor Power Supply Status Index
apEnvMonPowerSupplyStatusIndex 1.3.6.1.4.1.9148.3.3.1.5.1.1.1 (defined in ACMEPACKET-ENVMON-MIB)
Unique index for the power supply being instrumented. This index is for SNMP purposes only.
environmental monitor Power Supply Status Type
apEnvMonPowerSupplyStatusType 1.3.6.1.4.1.9148.3.3.1.5.1.1.2 (defined in ACMEPACKET-ENVMON-MIB)
The entity part type from which the power status is from. 0=left:power supply A, 1=right:power supply B. 3=slot: power supply is contained in the slot corresponding to apEnvMonPowerSowerSupplyStatusIndex
environmental monitor Power Supply Status Description
apEnvMonPowerSupplyStatusDescr 1.3.6.1.4.1.9148.3.3.1.5.1.1.3 (defined in ACMEPACKET-ENVMON-MIB)
Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.
shelf Power Supply Admin Status
shelfPowerSupplyAdminStatus 1.3.6.1.4.1.43.1.12.3.1.1.2.3.1.2 (defined in 3comab9300)
AdmAdmininistrative status.
shelf Power Supply Operation Status
shelfPowerSupplyOperStatus 1.3.6.1.4.1.43.1.12.3.1.1.2.3.1.3 (defined in 3comab9300)
Operational status for Power Supply. In AB9300/AB9100, it doesn't support any setting value. ::= { shelfPowerSupplyEntry 3 } SYNTAX OCTET STRING (SIZE(1..1)) ACCESS read-only STATUS mandatory DESCRIPTION Part number of the shelf.
Compaq CR3500 RAID Controller EMU Power Supply Status
cpqCrEMUPowerSupplyStatus 1.3.6.1.4.1.232.141.2.7.8 (defined in CPQCR)
Primary enclosure power supply status. The primary enclosure power supply status is: OK (2) Status is normal. Critical (3) Power supply is installed and marked as failed. Not Installed (4) One of the redundant power supplies has been removed. Unknown (5) Information unavailable.
Compaq CR3500 RAID Controller Expansion Cabinet Power Supply Status
cpqCrExpCabPowerSupplyStatus 1.3.6.1.4.1.232.141.2.8.1 (defined in CPQCR)
Expansion Cabinet power supply status. The expansion cabinet power supply status is: OK (2) Status is normal. Either redundant power supplies are installed and reporting no error or a single power supply is installed. Non-Critical (3) Redundant power supplies are installed and reporting a fault. Unknown (5) Information unavailable.
Compaq Server Health Filter Tolerance Power Supply Status
cpqHeFltTolPowerSupplyStatus 1.3.6.1.4.1.232.6.2.9.3.1.5 (defined in CPQHLTH)
The status of the power supply.
Compaq Rack Power Supply Status
cpqRackPowerSupplyStatus 1.3.6.1.4.1.232.22.2.5.1.1.1.14 (defined in CPQRACK)
The status of the power supply.
Compaq Rack Power Supply Input Line Status
cpqRackPowerSupplyInputLineStatus 1.3.6.1.4.1.232.22.2.5.1.1.1.15 (defined in CPQRACK)
The status of line input power.
Compaq Storage System Power Supply Status
cpqSsPowerSupplyStatus 1.3.6.1.4.1.232.8.2.2.3.1.4 (defined in CPQSTSYS)
Compaq Storage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply.
Compaq Storage System Power Supply Ups Status
cpqSsPowerSupplyUpsStatus 1.3.6.1.4.1.232.8.2.2.3.1.5 (defined in CPQSTSYS)
Compaq Storage System Power Supply Uninterruptible Power Supply (UPS) Status. The following values are defined: other(1) The agent is unable to determine if this power supply is attached to an Uninterruptible Power Supply (UPS). noUps(2) No UPS is attached to the power supply. ok(3) A UPS is attached to the power supply and is operating normally. powerFailed(4) A UPS is attached to the power supply and the AC power has failed. batteryLow(5) A UPS is attached to the power supply, the AC power has failed and the UPS battery is low.
Enterasys Pse Power Supply Status Table
etsysPsePowerSupplyStatusTable 1.3.6.1.4.1.5624.1.2.50.1.3.6 (defined in enterasys-power-ethernet-mib-ext-mib)
Status information for all of the Pse power supply modules.
Enterasys Pse Power Supply Status Entry
etsysPsePowerSupplyStatusEntry 1.3.6.1.4.1.5624.1.2.50.1.3.6.1 (defined in enterasys-power-ethernet-mib-ext-mib)
Status information for an individual Pse power supply module.
Enterasys Pse Power Supply Module Status
etsysPsePowerSupplyModuleStatus 1.3.6.1.4.1.5624.1.2.50.1.3.6.1.2 (defined in enterasys-power-ethernet-mib-ext-mib)
Denotes the power supply's status.

MIBs list