OIDs - Power Supply Status monitor
The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for power supply status
- Sys Power Supply Status Table
- a3ComSysPowerSupplyStatusTable 1.3.6.1.4.1.43.29.4.4.2 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
A list of power supply status entries. - Sys Power Supply Status Entry
- a3ComSysPowerSupplyStatusEntry 1.3.6.1.4.1.43.29.4.4.2.1 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
A power supply status entry contains information about a particular power supply. - Sys Power Supply Status Index
- a3ComSysPowerSupplyStatusIndex 1.3.6.1.4.1.43.29.4.4.2.1.1 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
The unique index of the power supply identified by this entry. - Sys Power Supply Status
- a3ComSysPowerSupplyStatus 1.3.6.1.4.1.43.29.4.4.2.1.2 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
This object represents the power supply status. The value is a sum. It initially takes on the value 0, then for each type which is active, 2 raised to a power is added to the sum. The powers are according to the following table. For the 6000 Backbone Aggregator an over temp for power supply 1 and power supply 2 will be reported as a power supply 1 Over Temperature Failure, and a fan failure will be reported as a power supply 2 Over Temperature Failure. Failure Type Power AC Failure 0 Plus 5 Failure 1 Plus 12 Failure 2 Over Temperature Failure 3 Power Supply Inserted 4 Power Supply Extracted 5 - Sys Power Supply Status Supported
- a3ComSysPowerSupplyStatusSupported 1.3.6.1.4.1.43.29.4.4.2.1.3 (defined in A3COM-SWITCHING-SYSTEMS-MIB)
This object represents the various power supply status types which are supported. The value is a sum. It initially takes on the value 0, then for each type which is supported, 2 raised to a power is added to the sum. The powers are according to the following table: Failure Type Power AC Failure 0 Plus 5 Failure 1 Plus 12 Failure 2 Over Temperature Failure 3 Power Supply Inserted 4 Power Supply Extracted 5 This object used in conjunction with the a3ComSysPowerSupplyStatus object for a given power supply provide a complete picture of the status of the power supply. - environmental monitor Power Supply Status Table
- apEnvMonPowerSupplyStatusTable 1.3.6.1.4.1.9148.3.3.1.5.1 (defined in ACMEPACKET-ENVMON-MIB)
The table of power supply status maintained by the environmental monitor card. - environmental monitor Power Supply Status Entry
- apEnvMonPowerSupplyStatusEntry 1.3.6.1.4.1.9148.3.3.1.5.1.1 (defined in ACMEPACKET-ENVMON-MIB)
An entry in the power supply status table, representing the status of the associated power supply maintained by the environmental monitor card. - environmental monitor Power Supply Status Index
- apEnvMonPowerSupplyStatusIndex 1.3.6.1.4.1.9148.3.3.1.5.1.1.1 (defined in ACMEPACKET-ENVMON-MIB)
Unique index for the power supply being instrumented. This index is for SNMP purposes only. - environmental monitor Power Supply Status Type
- apEnvMonPowerSupplyStatusType 1.3.6.1.4.1.9148.3.3.1.5.1.1.2 (defined in ACMEPACKET-ENVMON-MIB)
The entity part type from which the power status is from. 0=left:power supply A, 1=right:power supply B. 3=slot: power supply is contained in the slot corresponding to apEnvMonPowerSowerSupplyStatusIndex - environmental monitor Power Supply Status Description
- apEnvMonPowerSupplyStatusDescr 1.3.6.1.4.1.9148.3.3.1.5.1.1.3 (defined in ACMEPACKET-ENVMON-MIB)
Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry. - shelf Power Supply Admin Status
- shelfPowerSupplyAdminStatus 1.3.6.1.4.1.43.1.12.3.1.1.2.3.1.2 (defined in 3comab9300)
AdmAdmininistrative status. - shelf Power Supply Operation Status
- shelfPowerSupplyOperStatus 1.3.6.1.4.1.43.1.12.3.1.1.2.3.1.3 (defined in 3comab9300)
Operational status for Power Supply. In AB9300/AB9100, it doesn't support any setting value. ::= { shelfPowerSupplyEntry 3 } SYNTAX OCTET STRING (SIZE(1..1)) ACCESS read-only STATUS mandatory DESCRIPTION Part number of the shelf. - Compaq CR3500 RAID Controller EMU Power Supply Status
- cpqCrEMUPowerSupplyStatus 1.3.6.1.4.1.232.141.2.7.8 (defined in CPQCR)
Primary enclosure power supply status. The primary enclosure power supply status is: OK (2) Status is normal. Critical (3) Power supply is installed and marked as failed. Not Installed (4) One of the redundant power supplies has been removed. Unknown (5) Information unavailable. - Compaq CR3500 RAID Controller Expansion Cabinet Power Supply Status
- cpqCrExpCabPowerSupplyStatus 1.3.6.1.4.1.232.141.2.8.1 (defined in CPQCR)
Expansion Cabinet power supply status. The expansion cabinet power supply status is: OK (2) Status is normal. Either redundant power supplies are installed and reporting no error or a single power supply is installed. Non-Critical (3) Redundant power supplies are installed and reporting a fault. Unknown (5) Information unavailable. - Compaq Server Health Filter Tolerance Power Supply Status
- cpqHeFltTolPowerSupplyStatus 1.3.6.1.4.1.232.6.2.9.3.1.5 (defined in CPQHLTH)
The status of the power supply. - Compaq Rack Power Supply Status
- cpqRackPowerSupplyStatus 1.3.6.1.4.1.232.22.2.5.1.1.1.14 (defined in CPQRACK)
The status of the power supply. - Compaq Rack Power Supply Input Line Status
- cpqRackPowerSupplyInputLineStatus 1.3.6.1.4.1.232.22.2.5.1.1.1.15 (defined in CPQRACK)
The status of line input power. - Compaq Storage System Power Supply Status
- cpqSsPowerSupplyStatus 1.3.6.1.4.1.232.8.2.2.3.1.4 (defined in CPQSTSYS)
Compaq Storage System Power Supply Status. The following values are defined: other(1) The agent is unable to determine if this storage system power supply bay is occupied. notInstalled(2) Nothing is installed in this power supply bay. ok(3) A power supply is installed and operating normally. failed(4) A power supply is installed and is no longer operating. Replace the power supply. - Compaq Storage System Power Supply Ups Status
- cpqSsPowerSupplyUpsStatus 1.3.6.1.4.1.232.8.2.2.3.1.5 (defined in CPQSTSYS)
Compaq Storage System Power Supply Uninterruptible Power Supply (UPS) Status. The following values are defined: other(1) The agent is unable to determine if this power supply is attached to an Uninterruptible Power Supply (UPS). noUps(2) No UPS is attached to the power supply. ok(3) A UPS is attached to the power supply and is operating normally. powerFailed(4) A UPS is attached to the power supply and the AC power has failed. batteryLow(5) A UPS is attached to the power supply, the AC power has failed and the UPS battery is low. - Enterasys Pse Power Supply Status Table
- etsysPsePowerSupplyStatusTable 1.3.6.1.4.1.5624.1.2.50.1.3.6 (defined in enterasys-power-ethernet-mib-ext-mib)
Status information for all of the Pse power supply modules. - Enterasys Pse Power Supply Status Entry
- etsysPsePowerSupplyStatusEntry 1.3.6.1.4.1.5624.1.2.50.1.3.6.1 (defined in enterasys-power-ethernet-mib-ext-mib)
Status information for an individual Pse power supply module. - Enterasys Pse Power Supply Module Status
- etsysPsePowerSupplyModuleStatus 1.3.6.1.4.1.5624.1.2.50.1.3.6.1.2 (defined in enterasys-power-ethernet-mib-ext-mib)
Denotes the power supply's status.