SNMP up_threshold monitoring
The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for up threshold
- Compaq Fibre Array Fibre Channel Array Physical Drive Threshold Spin up Time
- cpqFcaPhyDrvThrSpinupTime 1.3.6.1.4.1.232.16.2.6.1.1.4 (defined in CPQFCA)
Spin up Time Maximum Threshold in tenths of seconds. This shows the maximum of time it takes for a physical drive to spin up to full speed. This threshold is associated with the cpqFcaPhyDrvSpinupTime object in the Physical Drive Table. If the value cannot be determined, -1 is returned. - Compaq Fibre Array Fibre Channel Array Physical Drive Threshold Violation Spin up Time
- cpqFcaPhyDrvThrViSpinupTime 1.3.6.1.4.1.232.16.2.6.1.1.9 (defined in CPQFCA)
Spin up Time in tenths of seconds Threshold Has Been Violated. This is used to indicate whether the time it took for a physical drive to spin up to full speed has ever exceeded the maximum allowable threshold. The valid values are: false (1) Indicates that the Spin up Time object (cpqFcaPhyDrvSpinupTime) value has not exceeded the maximum threshold (cpqFcaPhyDrvThrSpinupTime). true (2) Indicates that the Spin up Time object (cpqFcaPhyDrvSpinupTime) value has exceeded the maximum threshold (cpqFcaPhyDrvThrSpinupTime). unknown (3) The agent is unable to determine if the drive has a threshold violation. - Compaq Drive Array Physical Drive Threshold Spin up Time
- cpqDaPhyDrvThrSpinupTime 1.3.6.1.4.1.232.3.2.6.1.1.11 (defined in CPQIDA)
Spin up Time Maximum Threshold in tenths of seconds. This shows the maximum of time it takes for a physical drive to spin up to full speed. This threshold is associated with the cpqDaPhyDrvSpinupTime object in the Physical Drive Table. - Compaq Drive Array Physical Drive Threshold Spin up Retries
- cpqDaPhyDrvThrSpinupRetries 1.3.6.1.4.1.232.3.2.6.1.1.17 (defined in CPQIDA)
Spin up Retries Maximum Threshold. This shows the maximum threshold of the number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phyDrvRefTime). This threshold is associated with the cpqDaPhyDrvSpinupRetries object in the Physical Drive Table. - Compaq Drive Array Physical Drive Threshold Spin Up Errors
- cpqDaPhyDrvThrSpinUpErrs 1.3.6.1.4.1.232.3.2.6.1.1.28 (defined in CPQIDA)
Physical Drive Spin-Up Failure Count Maximum Threshold. This shows the maximum threshold of the number of times this physical drive was failed due to a failure of a spin-up command. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers. This threshold is associated with the cpqDaPhyDrvSpinUpErrs object in the Physical Drive Table. - Compaq Drive Array Physical Drive Threshold Violation Spin up Time
- cpqDaPhyDrvThrViSpinupTime 1.3.6.1.4.1.232.3.2.6.1.1.31 (defined in CPQIDA)
Spin up Time in tenths of seconds Threshold Has Been Violated. This is used to indicate whether the time it took for a physical drive to spin up to full speed has ever exceeded the maximum allowable threshold. The valid values are: false (1) Indicates that the Spin up Time object (cpqDaPhyDrvSpinupTime) value has not exceeded the maximum threshold (cpqDaPhyDrvThrSpinupTime). true (2) Indicates that the Spin up Time object (cpqDaPhyDrvSpinupTime) value has exceeded the maximum threshold (cpqDaPhyDrvThrSpinupTime). unknown (4294967295) The agent is unable to determine if the drive has a threshold violation. - sfcs BW Port Pool Trap Management Buffer Up Threshold
- sfcsBWPortPoolTrapMgmtBuffUpThold 1.3.6.1.4.1.52.4.1.2.11.1.1.12.3.3.1.42 (defined in ctron-sfcs-mib)
The upper threshold for buffer allocation trap . - sfcs Buffer Prio Up Threshold Trap
- sfcsBuffPrioUpTholdTrap 1.3.6.1.4.1.52.4.1.2.11.1.1.12.4.1.1.10 (defined in ctron-sfcs-mib)
The upper threshold of allocations to trigger an upper thold trap. - Cisco Cable QOS monitor Cmts If Bandwidth Utilization Up Threshold
- ccqmCmtsIfBwUtilUpThreshold 1.3.6.1.4.1.9.9.341.1.3.1.1.1 (defined in CISCO-CABLE-QOS-MONITOR-MIB)
This object defines the upper threshold for the interface bandwidth utilization and when interface bandwidth utilization exceeds this threshold, monitoring of the appropriate modem's service flow will start if there is an asociated enforce-rule present. This object can't be set to a value lower than ccqmCmtsIfBwUtilLoThreshold. - Cisco Cable Spectrum Up Spec Management Missed Maint Message Threshold
- ccsUpSpecMgmtMissedMaintMsgThres 1.3.6.1.4.1.9.9.114.1.3.1.1.21 (defined in CISCO-CABLE-SPECTRUM-MIB)
The missed maintenance message threshold in percentage. A value 0 indicates that the interface has no spectrum group assigned. i.e. ccsUpSpecMgmtSpecGroup equals 0.