SNMP OIDs - ups_output_voltage
The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for ups output voltage
- ups Output Voltage
- upsOutputVoltage 1.3.6.1.4.1.52.4.1.1.10.5.4.1.2 (defined in rfc1628)
The present output voltage. - ups Config Output Voltage
- upsConfigOutputVoltage 1.3.6.1.2.1.33.1.9.3 (defined in rfc1628)
The magnitude of the nominal output voltage. On those systems which support read-write access to this object, if there is an attempt to set this variable to a value that is not supported, the request must be rejected and the agent shall respond with an appropriate error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2. - ups Output Voltage
- upsOutputVoltage 1.3.6.1.4.1.52.4.1.1.10.5.4.1.2 (defined in ups2-mib)
The measured UPS output voltage. The value of this object is the actual voltage * 10 (that is, to determine the actual voltage, divide the value of this object by 10). - ups Output Utility Voltage
- upsOutputUtilityVoltage 1.3.6.1.4.1.52.4.1.1.10.5.1.1.2 (defined in ups2-mib)
The UPS's current on-battery output voltage setting (valid for 220/230/240 Vac version UPSs only). For other version UPSs, reading this object will always return a 0 and writing this object will have no effect. - ups Adv Output Voltage
- upsAdvOutputVoltage 1.3.6.1.4.1.318.1.1.1.4.2.1 (defined in PowerNet-MIB)
The output voltage of the UPS system in VAC. - ups Adv Config Rated Output Voltage
- upsAdvConfigRatedOutputVoltage 1.3.6.1.4.1.318.1.1.1.5.2.1 (defined in PowerNet-MIB)
The nominal output voltage from the UPS in VAC. Possible values are 100, 120, 208, 220, 225, 230 and 240. NOTE: Only units that are 220, 225, 230 and 240 can be changed. Allowable set values are 220, 225, 230, and 240. For these adjustable units, if a value other than a supported value is provided in a set request, the UPS interprets it as the next lower acceptable value. If the provided value is lower than the lowest acceptable value, the lowest acceptable value is used. - UPS Manager Config Output Nominal Voltage
- upsmgConfigOutputNominalVoltage 1.3.6.1.4.1.705.1.4.15 (defined in MG-SNMP-UPS-MIB)
The nominal output voltage. - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-UPSTATION-S3-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-UPSTATION-S3-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-UPSTATION-S-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-UPSTATION-S-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-UPSTATION-GXT-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-UPSTATION-GXT-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-UPSTATION-G-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-UPSTATION-D-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-UPSTATION-D-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-SERIES-600-UPS-MODULE-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-SERIES-600-UPS-MODULE-MIB)
The nominal output voltage. (Unit of measure: volt) - LIEBERT SERIES Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-SERIES-600-UPS-CONTROL-CABINET-MIB)
The output voltage. (Unit of measure: Volt) - LIEBERT SERIES Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-SERIES-600-UPS-CONTROL-CABINET-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-SERIES-4300-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-SERIES-4300-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-SERIES-300-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-SERIES-300-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-SERIES-200-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-SERIES-200-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Output Voltage
- lcUpsOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 (defined in LIEBERT-POWERSURE-INTERACTIVE-UPS-MIB)
The output voltage. (Unit of measure: Volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-POWERSURE-INTERACTIVE-UPS-MIB)
The nominal output voltage. (Unit of measure: volt) - Liebert Ups Nominal Output Voltage
- lcUpsNominalOutputVoltage 1.3.6.1.4.1.476.1.1.1.1.9.1 (defined in LIEBERT-MICRO-UPS-MIB)
The nominal output voltage. (Unit of measure: volt)