HW-IMAPV1NORTHBOUND-TRAP-MIB

HW-IMAPV1NORTHBOUND-TRAP-MIB Download

MIBs list

IPHost Network Monitor offer an easy way of SNMP monitoring your Huawei Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for HW-IMAPV1NORTHBOUND-TRAP-MIB

thirdNMSFaultFilter
This is to add the filter condition by the upper NMS the syntax is IP:Port:Alarm Level Example : 127.0.0.1:161:0011 In this IP is 127.0.0.1 Port is 161 Alarm Level - Minor and warning should not be sent as the bit is set for them
hwNmNorthboundNEName
The name of network element,string (255)
hwNmNorthboundNEType
Device type of element,string(64)
hwNmNorthboundObjectInstance
Instance of element,such as number of Rack, Frame, Slot, Subslot, Port and so on,string(255)
hwNmNorthboundEventType
Event type of Network management,string(64)
hwNmNorthboundEventTime
Alarm generate time,string(64),format: 2003/03/14 00:00:00
hwNmNorthboundProbableCause
Reason of Probable caused alarm, string(64)
hwNmNorthboundSeverity
Level of Alarm, string(64)
hwNmNorthboundEventDetail
Alarm ID and detail information, format: ID+detail infomation, string(255)
hwNmNorthboundAdditionalInfo
Additional infomation of device, such as Country, City and so on, string(255)
hwNmNorthboundFaultFlag
The flag of the fault.Show whether the alarm is an event ,a fault alarm or a recovery alarm.
hwNmNorthboundFaultFunction
The function type of the alarm.It can be one of these values:'Power','Environment','Signal','Relay','Hardware','Software','Run','Communication','Service','Processerror','UNKNOWN_FUC_TYPE'
hwNmNorthboundDeviceIP
The IP address of the device
hwNmNorthboundSerialNo
The serial number of alarm.
hwNmNorthboundProbableRepair
The probable repair advice of the alarm.
hwNmNorthboundResourceIDs
The ID of the resource.
hwNmNorthboundsAdditionalVB1
Addtional information of the alarm
hwNmNorthboundsAdditionalVB2
Addtional information of the alarm
hwNmNorthboundsAdditionalVB3
Addtional information of the alarm
hwNmNorthboundsAdditionalVB4
Addtional information of the alarm
hwNmNorthboundsAdditionalVB5
Addtional information of the alarm
hwNmNorthboundsAdditionalVB6
Addtional information of the alarm
hwNmNorthboundsAdditionalVB7
Addtional information of the alarm
hwNmNorthboundsAdditionalVB8
Addtional information of the alarm
hwNmNorthboundEventName
The name of event,string (255)
hwNmNorthboundEventSynchronizationEndStatus
It shows the result of alarm synchronization. 1 means the alarm synchronization successfully ended. 2 means the alarm synchronization is stopped by the NMS's command. 3 means some error occured during the alarm synchronization.
hwNmNorthboundEventSynchronizationEndStatusDetail
The detail description of the alarm synchronization end status.
hwNmNorthboundEventSynchronizationCommandStart
This node is to be set to start the alarm synchronization. It should be set as 'NMS's IP:port',and the agent will send alarm synchronization result to the IP and port specified. If there is already an running alarm synchronization for that IP and port,it ...
hwNmNorthboundEventSynchronizationCommandStop
This node is to be set to stop the alarm synchronization. It should be set as 'NMS's IP:port',and the agent will stop alarm synchronization for the IP and port specified. If there is no such an running alarm synchronization for that IP and port,it will re ...

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.

MIBs list