ctron-fddi-fnb-mib Download
You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the
ctron-fddi-fnb-mib
.
OID list for ctron-fddi-fnb-mib
- ctFDDIResourceEntry
- Defines a specific physical resource entry
- ctFDDIResourceSlotID
- A specific instance of a slot as defined by chSlotID as defined in the chassis MIB.
- ctFDDIResourceID
- A unique index that defines a specific physcial resource for which this relationship exists. The value of this is as defined by chResourceID in the chassis MIB.
- ctFDDIResourceType
- Defines the type of resource. This is the same value as chResourceType in the chassis MIB.
- ctFDDIResourceNumbInstance
- This object defines the number of instances of a physical resource. Specific resource instances are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of a resource from the top to the bottom, then the numbering ...
- ctFDDINonMuxCapTable
- This table describes all possible capabilities/configurations for all non-muxed FDDI configurations within the chassis.
- ctFDDINonMuxCapEntry
- Describes a particular capability/configuration entry.
- ctFDDINMSlot
- The slot within the chassis for which this configuration information is defined.
- ctFDDINMConfigID
- The instance of a particular configuration.
- ctFDDINMConfig
- This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string ...
- ctFDDINMConfigDesc
- This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDINMConfig object.
- ctFDDINonMuxCapEnableTable
- This table describes the currently enabled configuration for each module.
- ctFDDINonMuxCapEnableEntry
- Describes a specific configuration enable entry.
- ctFDDINMEnableSlot
- A specific slot for which this configuration enable pertains.
- ctFDDINMCapEnable
- A specific configuration that is enabled. Enabling a configuration is done by writing the value of ctFDDINMConfigID for a specific configuration to this object. This object, when read, will return the value of ctFDDINMConfigID for the presently enabled co ...
- ctFDDINonMuxConnectionTable
- This table defines specific information for each defined FDDI/FNB connection. This maps the third sub identifier of ctFDDINMConfig to a particular SMT and MAC instance in the 1512 FDDI MIB.
- ctFDDINonMuxConnectionEntry
- Defines a specific configuration connection entry.
- ctFDDINMConnectionSlot
- A specific slot for which this connection entry is defined.
- ctFDDINMConnectionID
- Describes a specific connection identifier. Valid connection identifiers are defined by the third sub-identifier in ctFDDINMConfig as identified by ctFDDINMCapEnable.
- ctFDDINMSMT
- A specific instance of SMT for which this entry pertains.
- ctFDDINMMAC
- A specific MAC that this connection entry pertains.
- ctFDDINMBytes
- The bandwidth utilization in bytes per second.
- ctFDDINMFrames
- The bandwidth utilization in frames per second.
- ctFDDINonMuxInterfaceTable
- This table describs the number of interfaces defined by each non multiplexing FDDI FNB module.
- ctFDDINonMuxInterfaceEntry
- A specfic non multiplexing module interface definition.
- ctFDDINMInterSlot
- A specific slot for which this inteface entry is defined.
- ctFDDINMNumbInterfaces
- The number of interfaces defined on this particular module.
- ctFDDIMuxCapTable
- This table describes all possible configuration/capabilities defined for a FDDI multiplexing module.
- ctFDDIMuxCapEntry
- Describes a specfic FDDI multiplexor capability/configuration entry.
- ctFDDIMuxSlot
- Defines the slot within the chassis for which this multiplexed capability/configuration entry pertains.
- ctFDDIMuxConfigID
- The instance of a particular configuration.
- ctFDDIMuxConfig
- This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string ...
- ctFDDIMuxConfigDesc
- This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDIMuxConfig object.
- ctFDDIMuxCapEnableTable
- This table describes the currently enabled configuration for each module.
- ctFDDIMuxCapEnableEntry
- Describes a specific configuration enable entry.
- ctFDDIMuxEnableSlot
- A specific slot for which this configuration enable pertains.
- ctFDDIMuxCapEnable
- A specific instance of the configuration that is enabled. Setting this object with a specific value of ctFDDIMuxConfigID enabled that configuration. A request of the value of this object will return the value of ctFDDIMuxConfigID for the presently enable ...
- ctFDDIMuxMasterPortAssignmentChange
- Depicts the number of changes to the master port to multiplexor output mapping.
- ctFDDIMuxOutTable
- Describes the multiplexor outputs for each of the FNB multiplexor modules. This maps the multiplexor output to a specific instance of MAC and SMT in the FDDI MIB.
- ctFDDIMuxOutEntry
- Describes a particular multiplexor output.
- ctFDDIMuxOutSlot
- The given slot for which this multiplexor output information pertains.
- ctFDDIMuxOutID
- The specific instance of the multiplexor output. Instances of this object are used by the values of ctFDDIMuxConfig.
- ctFDDIMuxOutMACIndex
- The MAC instance of this multiplexor output. If this this object has a value greater than 0, then this value is the same as fddimibMACIndex. If this object has the value of 0, the given mux-out does not have a MAC.
- ctFDDIMuxOutSMTIndex
- Identifies the instance of SMT as defined within the FDDI MIB.
- ctFDDIMuxBytes
- The bandwidth utilization in bytes per second.
- ctFDDIMuxFrames
- The bandwidth utilization in frames per second.
- ctFDDIMuxMasterPortTable
- A list of entries that define master ports as they are defined for the given multiplexed FDDI connection.
- ctFDDIMuxMasterPortEntry
- A specific FDDI-FNB multiplexed master port definition.
- ctFDDIMuxMasterPortSlotID
- A specific instance of a slot as defined by chSlotID.
- ctFDDIMuxMasterPortID
- A unique identifier for this specific master port.
- ctFDDIMuxMasterPortAssignment
- Provides the masterport to multiplexor output mapping. This is as defined by ctFDDIMuxOutMacAssignment.
- ctFDDIMuxMasterPortIndex
- Defines a specific port within the FDDI MIBs fddimibPORTTable.
- ctFDDINumbModules
- Describes the number of modules that are present configurable thru the serial control portion of this MIB. This directly reflects the number of rows found within the ctFDDISerialConfigTable.
- ctFDDISerialConfigTable
- This table describes the adminstrative control over each of the FNB serial control modules.
- ctFDDISerialConfigEntry
- Describes the controls over a single FNB serial control entry.
- ctFDDISerialSlotID
- Defines the slot that this FNB serial control module is in. This is an instance of chSlotID as defined in the chassis MIB.
- ctFDDISerialAdminStatus
- Describes the adminstrative desired state for this FNB serial control module. insertFNB1(1) - The serial controlled module should be inserted into FNB-1 and bypass FNB-2. insertFNB2(2) - The serial contolled module should be inserted into FNB-2 and bypass ...
- ctFDDISerialOperStatus
- Describes the operational status of this FDDI serial controlled module. insertFNB1(1) - The serial controlled module is inserted into FNB-1 and bypassed from FNB-2. insertFNB2(2) - The serial controlled module is bypassed from FNB-1 and inserted into FNB- ...
- ctFDDIModuleFPIMTable
- This table describes the FPIMs that are on the front panel of each FDDI serial control module, if that module supports FPIMs.
- ctFDDIModuleFPIMEntry
- Describes a single FDDI FPIM on a module.
- ctFddiFPIMSlotID
- Defines the slot in which this module exists. This is an instance of chSlotID as found in the chassis MIB.
- ctFddiFPIM
- Defines the instance of the port for which this definition is made. Ports are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of ports from the top to the bottom, then the numbering will start from the left s ...
- ctFddiFPIMStatus
- Describes the link status of the given FPIM. A value of link(1) states that a link is present. A value of noLink(2) states that no link is present. A value of notSupported(3) means that link status is not supported by this port and is unknown.
- ctFddiFPIMType
- Describes the type of FPIM as found in ctron-oids.