ctron-fddi-fnb-mib

ctron-fddi-fnb-mib Download

MIBs list

You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the ctron-fddi-fnb-mib .

OID list for ctron-fddi-fnb-mib

ctFDDIResourceEntry
Defines a specific physical resource entry
ctFDDIResourceSlotID
A specific instance of a slot as defined by chSlotID as defined in the chassis MIB.
ctFDDIResourceID
A unique index that defines a specific physcial resource for which this relationship exists. The value of this is as defined by chResourceID in the chassis MIB.
ctFDDIResourceType
Defines the type of resource. This is the same value as chResourceType in the chassis MIB.
ctFDDIResourceNumbInstance
This object defines the number of instances of a physical resource. Specific resource instances are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of a resource from the top to the bottom, then the numbering ...
ctFDDINonMuxCapTable
This table describes all possible capabilities/configurations for all non-muxed FDDI configurations within the chassis.
ctFDDINonMuxCapEntry
Describes a particular capability/configuration entry.
ctFDDINMSlot
The slot within the chassis for which this configuration information is defined.
ctFDDINMConfigID
The instance of a particular configuration.
ctFDDINMConfig
This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string ...
ctFDDINMConfigDesc
This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDINMConfig object.
ctFDDINonMuxCapEnableTable
This table describes the currently enabled configuration for each module.
ctFDDINonMuxCapEnableEntry
Describes a specific configuration enable entry.
ctFDDINMEnableSlot
A specific slot for which this configuration enable pertains.
ctFDDINMCapEnable
A specific configuration that is enabled. Enabling a configuration is done by writing the value of ctFDDINMConfigID for a specific configuration to this object. This object, when read, will return the value of ctFDDINMConfigID for the presently enabled co ...
ctFDDINonMuxConnectionTable
This table defines specific information for each defined FDDI/FNB connection. This maps the third sub identifier of ctFDDINMConfig to a particular SMT and MAC instance in the 1512 FDDI MIB.
ctFDDINonMuxConnectionEntry
Defines a specific configuration connection entry.
ctFDDINMConnectionSlot
A specific slot for which this connection entry is defined.
ctFDDINMConnectionID
Describes a specific connection identifier. Valid connection identifiers are defined by the third sub-identifier in ctFDDINMConfig as identified by ctFDDINMCapEnable.
ctFDDINMSMT
A specific instance of SMT for which this entry pertains.
ctFDDINMMAC
A specific MAC that this connection entry pertains.
ctFDDINMBytes
The bandwidth utilization in bytes per second.
ctFDDINMFrames
The bandwidth utilization in frames per second.
ctFDDINonMuxInterfaceTable
This table describs the number of interfaces defined by each non multiplexing FDDI FNB module.
ctFDDINonMuxInterfaceEntry
A specfic non multiplexing module interface definition.
ctFDDINMInterSlot
A specific slot for which this inteface entry is defined.
ctFDDINMNumbInterfaces
The number of interfaces defined on this particular module.
ctFDDIMuxCapTable
This table describes all possible configuration/capabilities defined for a FDDI multiplexing module.
ctFDDIMuxCapEntry
Describes a specfic FDDI multiplexor capability/configuration entry.
ctFDDIMuxSlot
Defines the slot within the chassis for which this multiplexed capability/configuration entry pertains.
ctFDDIMuxConfigID
The instance of a particular configuration.
ctFDDIMuxConfig
This object defines a specific valid connection configuration. It will specify the connection state of all resource instances. If an instance of a resource is not specified, then it is disconnected. Each valid configuration is encoded in an ascii string ...
ctFDDIMuxConfigDesc
This object contains a textual description of a valid connection configuration. This is a more user-friendly representation of the configuration than the ctFDDIMuxConfig object.
ctFDDIMuxCapEnableTable
This table describes the currently enabled configuration for each module.
ctFDDIMuxCapEnableEntry
Describes a specific configuration enable entry.
ctFDDIMuxEnableSlot
A specific slot for which this configuration enable pertains.
ctFDDIMuxCapEnable
A specific instance of the configuration that is enabled. Setting this object with a specific value of ctFDDIMuxConfigID enabled that configuration. A request of the value of this object will return the value of ctFDDIMuxConfigID for the presently enable ...
ctFDDIMuxMasterPortAssignmentChange
Depicts the number of changes to the master port to multiplexor output mapping.
ctFDDIMuxOutTable
Describes the multiplexor outputs for each of the FNB multiplexor modules. This maps the multiplexor output to a specific instance of MAC and SMT in the FDDI MIB.
ctFDDIMuxOutEntry
Describes a particular multiplexor output.
ctFDDIMuxOutSlot
The given slot for which this multiplexor output information pertains.
ctFDDIMuxOutID
The specific instance of the multiplexor output. Instances of this object are used by the values of ctFDDIMuxConfig.
ctFDDIMuxOutMACIndex
The MAC instance of this multiplexor output. If this this object has a value greater than 0, then this value is the same as fddimibMACIndex. If this object has the value of 0, the given mux-out does not have a MAC.
ctFDDIMuxOutSMTIndex
Identifies the instance of SMT as defined within the FDDI MIB.
ctFDDIMuxBytes
The bandwidth utilization in bytes per second.
ctFDDIMuxFrames
The bandwidth utilization in frames per second.
ctFDDIMuxMasterPortTable
A list of entries that define master ports as they are defined for the given multiplexed FDDI connection.
ctFDDIMuxMasterPortEntry
A specific FDDI-FNB multiplexed master port definition.
ctFDDIMuxMasterPortSlotID
A specific instance of a slot as defined by chSlotID.
ctFDDIMuxMasterPortID
A unique identifier for this specific master port.
ctFDDIMuxMasterPortAssignment
Provides the masterport to multiplexor output mapping. This is as defined by ctFDDIMuxOutMacAssignment.
ctFDDIMuxMasterPortIndex
Defines a specific port within the FDDI MIBs fddimibPORTTable.
ctFDDINumbModules
Describes the number of modules that are present configurable thru the serial control portion of this MIB. This directly reflects the number of rows found within the ctFDDISerialConfigTable.
ctFDDISerialConfigTable
This table describes the adminstrative control over each of the FNB serial control modules.
ctFDDISerialConfigEntry
Describes the controls over a single FNB serial control entry.
ctFDDISerialSlotID
Defines the slot that this FNB serial control module is in. This is an instance of chSlotID as defined in the chassis MIB.
ctFDDISerialAdminStatus
Describes the adminstrative desired state for this FNB serial control module. insertFNB1(1) - The serial controlled module should be inserted into FNB-1 and bypass FNB-2. insertFNB2(2) - The serial contolled module should be inserted into FNB-2 and bypass ...
ctFDDISerialOperStatus
Describes the operational status of this FDDI serial controlled module. insertFNB1(1) - The serial controlled module is inserted into FNB-1 and bypassed from FNB-2. insertFNB2(2) - The serial controlled module is bypassed from FNB-1 and inserted into FNB- ...
ctFDDIModuleFPIMTable
This table describes the FPIMs that are on the front panel of each FDDI serial control module, if that module supports FPIMs.
ctFDDIModuleFPIMEntry
Describes a single FDDI FPIM on a module.
ctFddiFPIMSlotID
Defines the slot in which this module exists. This is an instance of chSlotID as found in the chassis MIB.
ctFddiFPIM
Defines the instance of the port for which this definition is made. Ports are physically located from top-to-bottom on a particular module. If there are multiple 'columns' of ports from the top to the bottom, then the numbering will start from the left s ...
ctFddiFPIMStatus
Describes the link status of the given FPIM. A value of link(1) states that a link is present. A value of noLink(2) states that no link is present. A value of notSupported(3) means that link status is not supported by this port and is unknown.
ctFddiFPIMType
Describes the type of FPIM as found in ctron-oids.

You can start network devices monitoring using free 30-day trial version of IPHost Network Monitor right now. Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access. The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.

MIBs list