OIDs - rs232_port
The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for rs232 port
- sys Rs232 Port
- sysRs232Port 1.3.6.1.4.1.43.1.12.3.1.1.1.4.1.1 (defined in 3comab9300)
The managed node has 2 serial ports: port 1 and port 2. - rs232 Port Type
- rs232PortType 1.3.6.1.2.1.10.33.2.1.2 (defined in rfc1317)
The port's hardware type. - rs232 Port In Sig Number
- rs232PortInSigNumber 1.3.6.1.2.1.10.33.2.1.3 (defined in rfc1317)
The number of input signals for the port in the input signal table (rs232PortInSigTable). The table contains entries only for those signals the software can detect. - rs232 Port In Speed
- rs232PortInSpeed 1.3.6.1.2.1.10.33.2.1.5 (defined in rfc1317)
The port's input speed in bits per second. - rs232 Asynchronous Port Table
- rs232AsyncPortTable 1.3.6.1.2.1.10.33.3 (defined in rfc1317)
A list of asynchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for synchronous ports. - rs232 Asynchronous Port Bits
- rs232AsyncPortBits 1.3.6.1.2.1.10.33.3.1.2 (defined in rfc1317)
The port's number of bits in a character. - rs232 Asynchronous Port Autobaud
- rs232AsyncPortAutobaud 1.3.6.1.2.1.10.33.3.1.5 (defined in rfc1317)
A control for the port's ability to automatically sense input speed. When rs232PortAutoBaud is 'enabled', a port may autobaud to values different from the set values for speed, parity, and character size. As a result a network management system may temporarily observe values different from what was previously set. - rs232 Asynchronous Port Overrun Errors
- rs232AsyncPortOverrunErrs 1.3.6.1.2.1.10.33.3.1.8 (defined in rfc1317)
Total number of characters with an overrun error, input from the port since system re-initialization and while the port state was 'up' or 'test'. - rs232 Sync Port Table
- rs232SyncPortTable 1.3.6.1.2.1.10.33.4 (defined in rfc1317)
A list of synchronous port entries. The maximum entry number is given by the value of rs232Number. Entries need not exist for asynchronous ports. - rs232 Sync Port Entry
- rs232SyncPortEntry 1.3.6.1.2.1.10.33.4.1 (defined in rfc1317)
Status and parameter values for a synchronous port. - rs232 Sync Port Frame Check Errors
- rs232SyncPortFrameCheckErrs 1.3.6.1.2.1.10.33.4.1.3 (defined in rfc1317)
Total number of frames with an invalid frame check sequence, input from the port since system re-initialization and while the port state was 'up' or 'test'. - rs232 Sync Port Transmit Underrun Errors
- rs232SyncPortTransmitUnderrunErrs 1.3.6.1.2.1.10.33.4.1.4 (defined in rfc1317)
Total number of frames that failed to be transmitted on the port since system re-initialization and while the port state was 'up' or 'test' because data was not available to the transmitter in time. - rs232 In Sig Port Index
- rs232InSigPortIndex 1.3.6.1.2.1.10.33.5.1.1 (defined in rfc1317)
The value of rs232PortIndex for the port to which this entry belongs. - rs232 Port Type
- rs232PortType 1.3.6.1.2.1.10.33.2.1.2 (defined in rfc1659)
The port's hardware type. - rs232 Port In Sig Number
- rs232PortInSigNumber 1.3.6.1.2.1.10.33.2.1.3 (defined in rfc1659)
The number of input signals for the port in the input signal table (rs232PortInSigTable). The table contains entries only for those signals the software can detect and that are useful to observe. - rs232 Port In Speed
- rs232PortInSpeed 1.3.6.1.2.1.10.33.2.1.5 (defined in rfc1659)
The port's input speed in bits per second. Note that non-standard values, such as 9612, are probably not allowed on most implementations. - rs232 Port Out Flow Type
- rs232PortOutFlowType 1.3.6.1.2.1.10.33.2.1.8 (defined in rfc1659)
The port's type of output flow control. 'none' indicates no flow control at this level. 'ctsRts' and 'dsrDtr' indicate use of the indicated hardware signals. - rs232 Asynchronous Port Bits
- rs232AsyncPortBits 1.3.6.1.2.1.10.33.3.1.2 (defined in rfc1659)
The port's number of bits in a character. - rs232 Asynchronous Port Parity
- rs232AsyncPortParity 1.3.6.1.2.1.10.33.3.1.4 (defined in rfc1659)
The port's sense of a character parity bit. - rs232 Asynchronous Port Autobaud
- rs232AsyncPortAutobaud 1.3.6.1.2.1.10.33.3.1.5 (defined in rfc1659)
A control for the port's ability to automatically sense input speed. When rs232PortAutoBaud is 'enabled', a port may autobaud to values different from the set values for speed, parity, and character size. As a result a network management system may temporarily observe values different from what was previously set. - rs232 Asynchronous Port Overrun Errors
- rs232AsyncPortOverrunErrs 1.3.6.1.2.1.10.33.3.1.8 (defined in rfc1659)
Total number of characters with an overrun error, input from the port since system re-initialization and while the port state was 'up' or 'test'. - rs232 Sync Port Table
- rs232SyncPortTable 1.3.6.1.2.1.10.33.4 (defined in rfc1659)
A list of asynchronous port entries. Entries need not exist for synchronous ports. - rs232 Sync Port Frame Check Errors
- rs232SyncPortFrameCheckErrs 1.3.6.1.2.1.10.33.4.1.3 (defined in rfc1659)
Total number of frames with an invalid frame check sequence, input from the port since system re-initialization and while the port state was 'up' or 'test'. - rs232 Sync Port Transmit Underrun Errors
- rs232SyncPortTransmitUnderrunErrs 1.3.6.1.2.1.10.33.4.1.4 (defined in rfc1659)
Total number of frames that failed to be transmitted on the port since system re-initialization and while the port state was 'up' or 'test' because data was not available to the transmitter in time. - rs232 Sync Port Receive Overrun Errors
- rs232SyncPortReceiveOverrunErrs 1.3.6.1.2.1.10.33.4.1.5 (defined in rfc1659)
Total number of frames that failed to be received on the port since system re-initialization and while the port state was 'up' or 'test' because the receiver did not accept the data in time. - rs232 Sync Port Aborted Frames
- rs232SyncPortAbortedFrames 1.3.6.1.2.1.10.33.4.1.7 (defined in rfc1659)
Number of frames aborted on the port due to receiving an abort sequence since system re-initialization and while the port state was 'up' or 'test'. - rs232 Sync Port Mode
- rs232SyncPortMode 1.3.6.1.2.1.10.33.4.1.12 (defined in rfc1659)
The mode of operation of the port with respect to the direction and simultaneity of data transfer. fdx when frames on the data link can be transmitted and received at the same time hdx when frames can either be received from the data link or transmitted onto the data link but not at the same time. simplex-receive when frames can only be received on this data link. simplex-send when frames can only be sent on this data link. - rs232 Sync Port Idle Pattern
- rs232SyncPortIdlePattern 1.3.6.1.2.1.10.33.4.1.13 (defined in rfc1659)
The bit pattern used to indicate an idle line. - rs232 In Sig Port Index
- rs232InSigPortIndex 1.3.6.1.2.1.10.33.5.1.1 (defined in rfc1659)
The value of rs232PortIndex for the port to which this entry belongs. - rs232 Out Sig Port Index
- rs232OutSigPortIndex 1.3.6.1.2.1.10.33.6.1.1 (defined in rfc1659)
The value of rs232PortIndex for the port to which this entry belongs.