The objects described here can be monitored with the IPHost Network Monitor. You can start SNMP monitoring using free 30-day trial version of IPHost right now.

OID list for server module

Compaq Server Health Os Common Module Index
cpqHeOsCommonModuleIndex 1.3.6.1.4.1.232.6.2.1.4.2.1.1 (defined in CPQHLTH)
A unique index for this module description.
Compaq Server Health Os Common Module Version
cpqHeOsCommonModuleVersion 1.3.6.1.4.1.232.6.2.1.4.2.1.3 (defined in CPQHLTH)
The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be null (size 0) string if the agent cannot provide the module version.
Compaq Server Health Os Common Module Date
cpqHeOsCommonModuleDate 1.3.6.1.4.1.232.6.2.1.4.2.1.4 (defined in CPQHLTH)
The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octet first.
Compaq Server Health Os Common Module Purpose
cpqHeOsCommonModulePurpose 1.3.6.1.4.1.232.6.2.1.4.2.1.5 (defined in CPQHLTH)
The purpose of the module described in this entry.
Compaq Host Server Os Common Module Index
cpqHoOsCommonModuleIndex 1.3.6.1.4.1.232.11.2.1.4.2.1.1 (defined in CPQHOST)
A unique index for this module description.
Compaq Host Server Os Common Module Version
cpqHoOsCommonModuleVersion 1.3.6.1.4.1.232.11.2.1.4.2.1.3 (defined in CPQHOST)
The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be null (size 0) string if the agent cannot provide the module version.
Compaq Host Server Os Common Module Date
cpqHoOsCommonModuleDate 1.3.6.1.4.1.232.11.2.1.4.2.1.4 (defined in CPQHOST)
The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octect first.
Compaq Host Server Os Common Module Purpose
cpqHoOsCommonModulePurpose 1.3.6.1.4.1.232.11.2.1.4.2.1.5 (defined in CPQHOST)
The purpose of the module described in this entry.
Compaq Specific PC Server Os Common Module Table
cpqSiOsCommonModuleTable 1.3.6.1.4.1.232.2.2.1.4.2 (defined in CPQSINFO)
A table of software modules that provide an interface to the device this MIB describes.
Compaq Specific PC Server Os Common Module Index
cpqSiOsCommonModuleIndex 1.3.6.1.4.1.232.2.2.1.4.2.1.1 (defined in CPQSINFO)
A unique index for this module description.
Compaq Specific PC Server Os Common Module Version
cpqSiOsCommonModuleVersion 1.3.6.1.4.1.232.2.2.1.4.2.1.3 (defined in CPQSINFO)
The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the agent cannot provide the module version.
Compaq Specific PC Server Memory Module Type
cpqSiMemModuleType 1.3.6.1.4.1.232.2.2.4.5.1.4 (defined in CPQSINFO)
Type of memory module installed. The value other(1) will be given if the type is not known. The value board(2) will be given if the memory module is permanently mounted (not modular) on a system board or memory expansion board.
Compaq Specific PC Server Memory Module Speed
cpqSiMemModuleSpeed 1.3.6.1.4.1.232.2.2.4.5.1.5 (defined in CPQSINFO)
Module memory speed in nanoseconds. The value zero (0) will be given if the module speed cannot be determined.
Compaq Specific PC Server Memory Module Part No
cpqSiMemModulePartNo 1.3.6.1.4.1.232.2.2.4.5.1.8 (defined in CPQSINFO)
The memory module's manufacturer part number. This field will be a null (size 0) string if the manufacturer part number is not available.
Compaq Specific PC Server Memory Module Date
cpqSiMemModuleDate 1.3.6.1.4.1.232.2.2.4.5.1.9 (defined in CPQSINFO)
The memory module date of manufacture. field octets contents range ===== ====== ====================== ======== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the date of manufacture is not available. The hour, minute, and second field will always be set to 0.
Compaq Specific PC Server Memory Module Hw Location
cpqSiMemModuleHwLocation 1.3.6.1.4.1.232.2.2.4.5.1.12 (defined in CPQSINFO)
A text description of the hardware location, on complex multi SBB hardware only, for the memory module. A NULL string indicates that the hardware location could not be determined or is irrelevant.
Compaq Standard PC Server Equipment Os Common Module Index
cpqSeOsCommonModuleIndex 1.3.6.1.4.1.232.1.2.1.4.2.1.1 (defined in CPQSTDEQ)
A unique index for this module description.
Compaq Standard PC Server Equipment Os Common Module Version
cpqSeOsCommonModuleVersion 1.3.6.1.4.1.232.1.2.1.4.2.1.3 (defined in CPQSTDEQ)
The module version in XX.YY format. Where XX is the major version number and YY is the minor version number. This field will be a null (size 0) string if the agent cannot provide the module version.
Compaq Standard PC Server Equipment Os Common Module Date
cpqSeOsCommonModuleDate 1.3.6.1.4.1.232.1.2.1.4.2.1.4 (defined in CPQSTDEQ)
The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minute 0..59 6 7 second 0..60 (use 60 for leap-second) This field will be set to year = 0 if the agent cannot provide the module date. The hour, minute, and second field will be set to zero (0) if they are not relevant. The year field is set with the most significant octect first.
Compaq Standard PC Server Equipment Os Common Module Purpose
cpqSeOsCommonModulePurpose 1.3.6.1.4.1.232.1.2.1.4.2.1.5 (defined in CPQSTDEQ)
The purpose of the module described in this entry.
Cisco Fabric Configuration Server Port Module Type
fcsPortModuleType 1.3.6.1.4.1.9.9.297.1.1.15.1.4 (defined in CISCO-FCS-MIB)
The module type of this port.

MIBs list