ALTIGA-HARDWARE-STATS-MIB Download
The Altiga Hardware Statistics MIB models counters and objects that are
of management interest for the hardware
IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges,
Firewalls, Repeaters.
OID list for ALTIGA-HARDWARE-STATS-MIB
- alHardwareCpuVoltage
- The current CPU voltage in centivolts.
- alHardwareCpuVoltageAlarm
- The alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range.
- alHardwareCpuVoltageCount
- The number of alarm events for CPU voltage.
- alHardwareCpuVoltageTime
- The sysUptime at the time of the last change of alarm status for CPU voltage.
- alHardwarePs1Voltage3v
- The current 3V voltage of Power Supply 1 in centivolts.
- alHardwarePs1Voltage3vAlarm
- The alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range.
- alHardwarePs1Voltage3vCount
- The number of alarm events for PS1 3v voltage.
- alHardwarePs1Voltage3vTime
- The sysUptime at the time of the last change of alarm status for PS1 3v voltage.
- alHardwarePs1Voltage5v
- The current 5V voltage of Power Supply 1 in centivolts.
- alHardwarePs1Voltage5vAlarm
- The alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range.
- alHardwarePs1Voltage5vCount
- The number of alarm events for PS1 5v voltage.
- alHardwarePs1Voltage5vTime
- The sysUptime at the time of the last change of alarm status for PS1 5v voltage.
- alHardwarePs2Voltage3v
- The current 3V voltage of Power Supply 2 in centivolts.
- alHardwarePs2Voltage3vAlarm
- The alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range.
- alHardwarePs2Voltage3vCount
- The number of alarm events for PS2 3v voltage.
- alHardwarePs2Voltage3vTime
- The sysUptime at the time of the last change of alarm status for PS2 3v voltage.
- alHardwarePs2Voltage5v
- The current 5V voltage of Power Supply 2 in centivolts.
- alHardwarePs2Voltage5vAlarm
- The alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range.
- alHardwarePs2Voltage5vCount
- The number of alarm events for PS2 5v voltage.
- alHardwarePs2Voltage5vTime
- The sysUptime at the time of the last change of alarm status for PS2 5v voltage.
- alHardwareBoardVoltage3v
- The current 3V voltage of the mainboard in centivolts.
- alHardwareBoardVoltage3vAlarm
- The alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range.
- alHardwareBoardVoltage3vCount
- The number of alarm events for the mainboard 3v voltage.
- alHardwareBoardVoltage3vTime
- The sysUptime at the time of the last change of alarm status for the mainboard 3v voltage.
- alHardwareBoardVoltage5v
- The current 5V voltage of the mainboard in centivolts.
- alHardwareBoardVoltage5vAlarm
- The alarm status for the mainboard 5v voltage. This alarm will fired when the 5v mainboard voltage is detected out of configured range.
- alHardwareBoardVoltage5vCount
- The number of alarm events for the mainboard 5v voltage.
- alHardwareBoardVoltage5vTime
- The sysUptime at the time of the last change of alarm status for the mainboard 5v voltage.
- alHardwareCpuTemp
- The current CPU temperature in degrees C.
- alHardwareCpuTempAlarm
- The alarm status for the CPU temperature. This alarm will fired when the CPU temperature is detected out of configured range.
- alHardwareCpuTempCount
- The number of alarm events for the CPU temperature.
- alHardwareCpuTempTime
- The sysUptime at the time of the last change of alarm status for the CPU temperature.
- alHardwareCageTemp
- The current cage temperature in degrees C.
- alHardwareCageTempAlarm
- The alarm status for the cage temperature. This alarm will fired when the cage temperature is detected out of configured range.
- alHardwareCageTempCount
- The number of alarm events for the cage temperature.
- alHardwareCageTempTime
- The sysUptime at the time of the last change of alarm status for the cage temperature.
- alHardwareFan1Rpm
- The current speed of fan 1 in RPM.
- alHardwareFan1RpmAlarm
- The alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM is detected out of configured range.
- alHardwareFan1RpmCount
- The number of alarm events for fan 1 RPM.
- alHardwareFan1RpmTime
- The sysUptime at the time of the last change of alarm status for fan 1 RPM.
- alHardwareFan2Rpm
- The current speed of fan 2 in RPM.
- alHardwareFan2RpmAlarm
- The alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM is detected out of configured range.
- alHardwareFan2RpmCount
- The number of alarm events for fan 2 RPM.
- alHardwareFan2RpmTime
- The sysUptime at the time of the last change of alarm status for fan 2 RPM.
- alHardwareFan3Rpm
- The current speed of fan 3 in RPM.
- alHardwareFan3RpmAlarm
- The alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM is detected out of configured range.
- alHardwareFan3RpmCount
- The number of alarm events for fan 3 RPM.
- alHardwareFan3RpmTime
- The sysUptime at the time of the last change of alarm status for fan 3 RPM.
- alHardwarePs1Type
- The type of power supply for Power Supply slot 1.
- alHardwarePs2Type
- The type of power supply for Power Supply slot 2.
- alHardwareSlot1Card
- The type of card in slot 1.
- alHardwareSlot2Card
- The type of card in slot 2.
- alHardwareSlot3Card
- The type of card in slot 3.
- alHardwareSlot4Card
- The type of card in slot 4.
- alHardwareSlot1Operational
- The operational status of card in slot 1.
- alHardwareSlot2Operational
- The operational status of card in slot 2.
- alHardwareSlot3Operational
- The operational status of card in slot 3.
- alHardwareSlot4Operational
- The operational status of card in slot 4.
- alHardwareRamSize
- The amount of memory, in MB on the concentrator.
- alHardwareChassis
- The type of VPN Concentrator this is.
- alHardwareCpuVoltageNominal
- The nominal CPU voltage in centivolts for the concentrator.
- alHardwareClientEthPrivSwitch
- Whether or not the 3002 Hardware Client has an Ethernet Switch for the private interface.
- alHardwareSerialNumber
- Unit serial number.
- altigaHardwareStatsGroup
- The objects for Hardware statistics.