CISCO-BSC-MIB

CISCO-BSC-MIB Download

MIBs list

The BSC MIB provides the configuration and operational information on Cisco's Binary Synchronous Communications implementation. The fo llowing entities are managed: 1) BSC ports (serial interfaces) 2) BSC Control Units (stations on a port)

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-BSC-MIB

bscPortTable
A list of port (serial interfaces) which have been configured to support a BSC BSTUN group.
bscPortEntry
Status and parameter values for a port.
bscPortRole
The router's DLC role to the attached node. If the bscPortRole is primary, this implies that the port is connected to a remote secondary device. If the role is generic, this indicates that the port will be running framed bisynchronous frames with an unkno ...
bscPortCodeSet
The code set used for the line controls.
bscPortPause
For primary, it is the minimum time to be taken for a cycle round the active poll table; if this time has not elapsed when the bottom of the poll table is reached, then polling will pause until this timer expires. A value of zero means there will be no pa ...
bscPortServlim
This parameter is valid for primary only. It is the number of times the active poll table will be cycled before a non-responding control unit will be polled. The default is 3.
bscPortPollTimeout
This parameter is valid for primary only. It is the time that the primary will wait for a response to a poll or select. The units are tenths of a second. The default is 10 (1 second).
bscPortRecoveryRetries
This is the number of times that a recovery sequence will be retried before the connection is considered to have failed. The default is 5.
bscPortUnknownControlUnitsReceived
Count of frames received from the serial interface with an unsupported control unit address. If this value is non-zero it indicates a problem in the configuration.
bscPortSoftErrors
Count of soft errors; these are errors which have been recovered. This includes CRC errors received, frames which were retransmitted for any reason (NAK received or the wrong ACK received), etc. This count is a measure of the quality of the port/line, b ...
bscPortHardErrors
Count of hard errors; these are errors which have not been recovered after bscPortRecoveryRetries number of retries, and therefore the connection has been terminated. These errors could be caused by a hardware error in the line or in the remote device; or ...
bscPortProtocolViolations
Count of protocol violations. This counter is incremented when an unexpected BSC Data Link Control character is received from the remote device; that is, the control character is invalid in the current state of the local BSC FSM. This indicates that ther ...
bscPortHostTimeout
This parameter is valid for interfaces configured secondary which additionally are running local-acknowledgement. If the configuration does not match the value will be shown as zero. It is the time the interface will wait for a poll from the host before p ...
bscPortSpecPoll
This parameter is valid for primary, local-acknowledgement interfaces only. It is set to TRUE when the interface is configured to treat specific polls as general polls. If the configuration cannot support this value, it will be set to FALSE. The default i ...
bscPortVirtualAddress
This parameter is valid for contention only. It is the address to be used for this interface when the remote peer router is being used as a concentrator. The default is 01.
bscPortContentionDialTimeout
This parameter is valid for dialContention only. It is the amount of time an interface can be quiescent before return the interface to the dial-in pool. The default is 5 seconds.
bscControlUnitTable
A table containing information about specific Control Units.
bscCUEntry
The information regarding a single Control Unit.
bscCUAddress
This value is the poll address of the BSC Control Unit. This address must be unique within a BSTUN Group.
bscCUState
State of the BSC Control Unit; when active this indicates that the remote Control Unit is polling or responding to polls.
bscCUBytesSent
Count of sent bytes (octets). Includes all control characters.
bscCUBytesReceived
Count of received bytes (octets). Includes all control characters.
bscCUTotalFramesSent
Count of sent frames (blocks). Includes all control frames.
bscCUTotalFramesReceived
Count of received frames (blocks). Includes all control frames.
bscCUDataFramesSent
Count of sent data frames (blocks).
bscCUDataFramesReceived
Count of received data frames (blocks).
bscCUSoftErrors
Count of soft errors; these are errors which have been recovered. This includes CRC errors received, frames which were retransmitted for any reason (NAK received or the wrong ACK received), etc. This count is a measure of the quality of the connection, ...
bscCUHardErrors
Count of hard errors; these are errors which have not been recovered after bscPortRecoveryRetries number of retries, and therefore the connection has been terminated. These errors could be caused by a hardware error in the link or in the remote device; or ...
bscCUProtocolViolations
Count of protocol violations. This counter is incremented when an unexpected BSC Data Link Control character is received from the remote device; that is, the control character is invalid in the current state of the local BSC FSM. This indicates that ther ...
bscExtAddressTable
List of all addresses configured by the bsc extended-address command. This applies only to interfaces with an ifType of 'bsc'. The address entries must be unique per interface.
bscExtAddressEntry
The information regarding a single extended addresses.
bscExtPollAddress
The poll address of the station configured by the bsc extended-address command.
bscExtSelectAddress
The select address of the station configured by the bsc extended-address command.
bscPortsGroup
A collection of objects providing information about BSC enabled interfaces.
bscControlUnitsGroup
A collection of objects providing information about BSC Control Units .
bscPortsGroupRev1
A collection of objects providing information about BSC enabled interfaces.
bscExtAddressGroup
A collection of objects providing information about BSC extended addresses.