cCallHistoryIecGroup
A collection of objects providing information about Internal Error Code.
cCallHistoryTable
A table containing information about specific calls to a specific destination.
cCallHistoryEntry
The information regarding a single Connection.
cCallHistoryIndex
A monotonically increasing integer for the sole purpose of indexing call disconnection events. When it reaches the maximum value, an extremely unlikely event, the agent wraps the value back to 1 and may flush existing entries.
cCallHistorySetupTime
The value of sysUpTime when the call setup was started. This will be useful for an NMS to sort the call history entry with call setup time. Also, this object can be useful in finding large delays between the time the call was started and the time the call ...
cCallHistoryPeerAddress
The number this call was connected to. If the number is not available, then it will have a length of zero.
cCallHistoryPeerSubAddress
The subaddress this call was connected to. If the subaddress is undefined or not available, this will be a zero length string.
cCallHistoryPeerId
This is the Id value of the peer table entry to which this call was made. If a peer table entry for this call does not exist, the value of this object will be zero.
cCallHistoryPeerIfIndex
This is the ifIndex value of the peer table entry to which this call was made. If a peer table entry for this call does not exist, the value of this object will be zero.
cCallHistoryLogicalIfIndex
This is the ifIndex value of the logical interface through which this call was made. For ISDN media, this would be the ifIndex of the B channel which was used for this call. If the ifIndex value is unknown, the value of this object will be zero. For an IP ...
cCallHistoryDisconnectCause
The encoded network cause value associated with this call. The value of this object will depend on the interface type as well as on the protocol and protocol version being used on this interface. Some references for possible cause values are given below.
cCallHistoryDisconnectText
ASCII text describing the reason for call termination. This object exists because it would be impossible for a management station to store all possible cause values for all types of interfaces. It should be used only if a management station is unable to d ...
cCallHistoryConnectTime
The value of sysUpTime when the call was connected.
cCallHistoryDisconnectTime
The value of sysUpTime when the call was disconnected.
cCallHistoryCallOrigin
The call origin.
cCallHistoryChargedUnits
The number of charged units for this connection. For incoming calls or if charging information is not supplied by the switch, the value of this object will be zero.
cCallHistoryInfoType
The information type for this call.
cCallHistoryTransmitPackets
The number of packets which were transmitted while this call was active.
cCallHistoryTransmitBytes
The number of bytes which were transmitted while this call was active.
cCallHistoryReceivePackets
The number of packets which were received while this call was active.
cCallHistoryReceiveBytes
The number of bytes which were received while this call was active.
cCallHistoryReleaseSource
Originator of the call release.
cCallHistoryReleaseSrc
Originator of the call release. Indicates the source of the call release as follows : 1) callingPartyInPstn : Calling party in PSTN. 2) callingPartyInVoip : Calling party in VoIP. 3) calledPartyInPstn : Called party in PSTN. 4) calledPartyInVoip : Called ...
cCallHistoryIecTable
This table contains information about Internal Error Code(s) (IEC) which caused the call to fail.
cCallHistoryIecEntry
The IEC information regarding a single call.
cCallHistoryIecIndex
This object is used to index one or more IECs in the context of a single call. In most cases there will only be one IEC when a call fails. However, it is possible for the software processing the call to generate multiple IECs before the call ultimately ...
cCallHistoryIec
This object reflects the Internal Error Code. The format is a string of dotted decimal numbers composed of the following components: Version.Entity.Category.Subsystem.Errorcode.Diagnostic Each component is defined as follows: Version : The version of ...
cPeerSearchType
Specifies the peer search preference based on the type of peers in an universal/integrated port platform. none - both voice and data peers are searched in same preference. datavoice - search data peers first. If no data peers are found, the voice pee ...
cCallHistoryGroup
A collection of objects providing the Call History capability.
cCallHistoryGroupRev1
A collection of objects providing the Call History capability.
cCallHistoryGroupRev2
A collection of objects providing the Call History capability.
cPeerGlobalConfigurationGroup
A collection of objects providing the Peer global configuration.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.

MIBs list