CISCO-ENTITY-PFE-MIB

CISCO-ENTITY-PFE-MIB Download

MIBs list

The Packet Forwarding Engine technology are Cisco developed Network Processors, which accelerates certain features in order to provide better network performance. An agent uses this MIB to monitor the performance history on any active PFE pipeline listed in the ENTITY-MIB (RFC 2737) entPhysicalTable. This monitoring is via measurement periods of actual, 1-minute, 5-minutes and 15-minutes. For the 1-minute and 5-minute measurement periods, perfor- mance statistics are calculated and displayed based on pre- vious 1 minute and 5 minute respectively. For the 15-minute period, the performance statistics are accumulated in fifteen minute intervals. At any one time, an agent maintains one current (incomplete) interval and up to 96 completed intervals (24 hours worth). Fewer than 96 intervals of data will be available if the agent has been restarted within the last 24 hours. In addition, there is a rolling 24-hour total of each performance statistic. There is no requirement for an agent to ensure fixed rela- tionship between the start of a fifteen minute interval and any wall clock; however some agents may align the fifteen minute intervals with quarter hours.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-ENTITY-PFE-MIB

cePfePerfConfigTable
This table contains configuration information on a PFE pipeline.
cePfePerfConfigEntry
An entry will exist for each entry in the entPhysicalTable that correspond to an active PFE pipeline.
cePfePerfConfigTimeElapsed
The number of seconds that have elapsed since the beginning of the current 15 min interval. If for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum valu ...
cePfePerfConfigValidIntervals
The number of completed 15 min intervals for which valid PFE performance data has been collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of completed 15 minute inte ...
cePfePerfConfigThldUtilization
This object contains the threshold value for the cePfePerfCurrentUtilization object. If during the last 5 second measurement period the cePfePerfCurrentUtilization object becomes greater than or equal to this threshold value, an event of type 'thldUtiliza ...
cePfePerfConfigThldEfficiency
This object contains the threshold value for the cePfePerfCurrentEffciency object. If during the last 5 second measurement period the cePfePerfCurrentEfficiency object becomes less than or equal to this threshold value, an event of type 'thldEfficiencyEve ...
cePfePerfConfigThld1MinUtilization
This object contains the threshold value for the cePfePerfCurrent1MinUtilization object. If during the last 1 minute measurement period the cePfePerfCurrent1MinUtilization object becomes greater than or equal to this threshold value, an event of type 'thl ...
cePfePerfConfigThld1MinEfficiency
This object contains the threshold value for the cePfePerfCurrent1MinEfficiency object. If during the last 1 minute measurement period the cePfePerfCurrent1MinEfficiency object becomes less than or equal to this threshold value, an event of type 'thld1Min ...
cePfePerfConfigThld5MinUtilization
This object contains the threshold value for the cePfePerfCurrent5MinUtilization object. If during the last 5 minute measurement period the cePfePerfCurrent5MinUtilization object becomes greater than or equal to this threshold value, an event of type 'thl ...
cePfePerfConfigThld5MinEfficiency
This object contains the threshold value for the cePfePerfCurrent5MinEfficiency object. If during the last 5 minute measurement period the cePfePerfCurrent5MinEfficiency object becomes less than or equal to this threshold value, an event of type 'thld5Min ...
cePfePerfCurrentTable
This table maintains PFE current running performance, which are collected at various measurement periods.
cePfePerfCurrentEntry
An entry containing performance information applicable to a particular PFE pipeline.
cePfePerfCurrentUtilization
This object provides the actual PFE percentage utilization. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
cePfePerfCurrentEfficiency
This object provides the actual PFE percentage efficiency. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, this number will be 100 and w ...
cePfePerfCurrent1MinUtilization
This object provides the PFE percentage utilization over the previous 1 minute period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
cePfePerfCurrent1MinEfficiency
This object provides the PFE percentage efficiency over the previous 1 minute period. It is determined by the totalnumber of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, thi ...
cePfePerfCurrent5MinUtilization
This object provides the PFE percentage utilization over the previous 5 minutes period. It is determined by the number of new work contexts + feedback contexts divided by total number of contexts that can be supported by the PFE pipeline.
cePfePerfCurrent5MinEfficiency
This object provides the PFE percentage efficiency over the previous 5 minutes period. It is determined by the total number of contexts per second divided by maximum theoretical contexts per second supported by the PFE pipeline. Under normal conditions, t ...
cePfePerfIntervalTable
This table contains performance statistics for completed 15 minutes intervals, specifically up to 96 such intervals over a 24 hours of operation.
cePfePerfIntervalEntry
An entry containing performance information applicable to a particular PFE pipeline at a specific interval.
cePfePerfIntervalNumber
An interval number between 1 and 96, where 1 is the most recently completed 15 min interval and 96 is the 15 min interval completed 23 hours and 45 minutes prior to interval 1.
cePfePerfIntervalUtilization
The percentage of processor utilization by the PFE pipeline during this completed 15 min interval.
cePfePerfIntervalEfficiency
The percentage of processor efficiency by the PFE pipeline during this completed 15 min interval. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
cePfePerfTotalTable
This table contains the running utilization and efficiency of the PFE pipeline for the 24 hour period preceding the current interval. If the agent was restarted less than 24 hours ago, i.e., when there are less than 96 intervals in the cePfePerfIntervalTa ...
cePfePerfTotalEntry
An entry containing performance information applicable to a particular PFE pipeline at the end of each interval in the cePfePerfIntervalTable.
cePfePerfTotalUtilization
The running utilization by the PFE pipeline for the prece- ding 24 hrs.
cePfePerfTotalEfficiency
The running efficiency by the PFE pipeline for the preceding 24 hrs. Under normal conditions, this number will be 100 and when efficiency starts degrading, it will start going down until it reaches zero.
cePfeHistNotifiesEnable
This object indicates what type of action should be taken by the agent when a event is generated.
cePfeHistTableSize
This object specifies the number of entries that the cePfeHistTable can contain. When a event is generated, and the capacity of the cePfeHistTable has reached the value specified by this object, then the agent deletes the oldest entity in order to accomm ...
cePfeHistTableLastIndex
This object specifies the value of the cePfeHistIndex object corresponding to the last entry added to the table by the agent. It will return zero if there are no entries in the table. If the management client uses the notifications defined by this module, ...
cePfeHistTable
This table contains a history of events generated by the agent.
cePfeHistEntry
An entry will exist for each event that has occured while cePfeHistNotifiesEnable object is set to 'log(2)' or 'logAndNotify(4)'.
cePfeHistIndex
An integer value uniquely identifying the entry in the table. The value of this object starts at '1' and monotonically increases for each event condition transition monitored by the agent. If the value of this object is '4294967295', the agent will reset ...
cePfeHistEntPhysIndex
The value in this object is equal to the value of the entPhysicalIndex, from the Physical Entity Table (RFC 2037), that is associated with the PFE pipeline that has caused this event.
cePfeHistType
This object describes the type of event that has occurred.
cePfeHistThld
The configured value of the specific threshold.
cePfeHistValue
The actual value of the specific performance objects, at the time of the sample, which is related to the threshold event.
cePfeHistRestartReason
The reason for which the PFE pipeline has restarted.
cePfeHistTimeStamp
This object specifies the value of the sysUpTime object at the time the event was generated.
cePfeMIBPerformanceGroup
The collection of objects which are used to manage the per- formance history of the PFE pipeline.
cePfeMIBCurrentGroup
The collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation.
cePfeMIBIntervalGroup
The collection of objects which are used to maintain the PFE processor's performance history over a 24 hour of operation.
cePfeMIBTotalGroup
The collection of objects which are used to manage the threshold configuration for the PFE pipeline performance.
cePfeMIBHistGroup
The collection of objects which are used to manage the threshold configuration for the PFE pipeline performance.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.