CISCO-ICSUDSU-MIB

CISCO-ICSUDSU-MIB Download

MIBs list

Integrated CSU/DSU MIB module. For T1 and Switched 56 kbps interfaces.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-ICSUDSU-MIB

ciscoICsuDsuStaticConfigTable
The CSU/DSU Static Configuration Table. Contains items that are statically configured and can not be changed by end user without physically changing the CSU/DSU.
ciscoICsuDsuStaticConfigEntry
An entry in the static configuration table for each integrated CSU/DSU.
ciscoICsuDsuType
Specifies the type of line interface or CSU/DSU.
ciscoICsuDsuHwRevision
The CSU/DSU hardware revision.
ciscoICsuDsuSwRevision
The CSU/DSU software revision.
ciscoICsuDsuProtocolRevision
The Protocol Revision of the CSU/DSU.
ciscoICsuDsuTestReportTable
The CSU/DSU test report Table. Contains the results of user initiated tests, including selftest, reset, and loopback.
ciscoICsuDsuTestReportEntry
An entry in the test report table for each integrated CSU/DSU.
ciscoICsuDsuLastSelfTestResult
The result of the last self test. Represented as a sum of a bit map. The variable bit positions are: 1 - Flash Checksum bad. Catastrophic error. 2 - EPROM Checksum bad. Catastrophic error. 4 - RAM Tests failed. Catastrophic error. 8 - ROM Checksum ba ...
ciscoICsuDsuTimeOfLastSelfTest
SysUpTime of LastSelfTest execution.
ciscoICsuDsuNumResets
Number of times CSU/DSU has been reset.
ciscoICsuDsuTimeOfLastReset
SysUpTime of last CSU/DSU reset.
ciscoICsuDsuLoopbackStatus
Current Status of Loopback. Remaining Loopback results are valid only if status is 'completed' or 'failed' or 'noSyncWithTestPattern'.
ciscoICsuDsuLoopbackNumErrors
Number of Bit errors that occurred in last successful loopback test. Valid only if remote loopback with pattern was performed and a sync was achieved on the test pattern.
ciscoICsuDsuLoopbackDuration
Duration of last successful loopback test in hundredths of seconds. Note that it is possible for the CSU/DSU to lose framing during the test. If so, the duration represents the time between reframing and end of test. This simply means that the start ti ...
ciscoICsuDsuLoopbackPoint
Point in network where last loopback was performed. Meaning for t1 CSU/DSU: dtePayload - local DSU loopback. The configured 'fractions' of the DS1 signal is looped back as the receive signal. Used to verify operation of DSU portion of local CSU/DSU. dteF ...
ciscoICsuDsuUserDefinedPattern
User Defined Loopback Pattern. Valid only if ciscoICsuDsuLoopbackPattern is patternUser.
ciscoICsuDsuLoopbackCode
LoopCode used to initiate last remote loopback. Valid only if a only if a remote loopback was last performed. standard - standard loopback code. Usually consists of the repeated binary pattern of '00001' alternate - alternate loopback code. Usually the ...
ciscoICsuDsuEndTimeOfLastLoopback
SysUpTime of completion of last loopback test execution.
ciscoICsuDsuT1ConfigTable
The T1 CSU/DSU Unit Configuration Table. Contains current T1 CSU/DSU configuration parameters not covered by RFC1406.
ciscoICsuDsuT1ConfigEntry
An entry in the configuration table for each integrated T1 CSU/DSU.
ciscoICsuDsuT1LineBuildOut
Line build out (LBO) is loss inserted by the CSU in order to meet the 15 to 22.5 dB loss requirement of the premises remote-end section. Selected so that (phone company loss) + (cable length loss) + (line build out) is greater that 15dB but less than 22 ...
ciscoICsuDsuT1DteLineCode
Indicates whether the DTE line code is inverted or not. When fractional timeslots are configured for 64kps and AMI linecode, a combination of inverting the DTE line code along with the proper line protocol (i.e. HDLC/SDLC) may be necessary to meet the one ...
ciscoICsuDsuT1SupportRemoteAlarmIndication
Determines if unit will generate or detect a remote alarm indication (RAI) signal which is also known as a yellow alarm. In D4 framing format, DTE equipment (including Frame Relay equipment) that is using the HDLC or SDLC protocol may generate patterns as ...
ciscoICsuDsuT1FullBandwidthRemoteLoopcode
LoopCode to be accepted from remote end to place unit in and out of full bandwidth loopback. standard - standard loopback code. Usually consists of the repeated binary pattern of '00001' alternate - alternate loopback code. Usually the inverse of the st ...
ciscoICsuDsuT1PayloadRemoteLoopcode
LoopCode to be accepted from remote end to place unit in and out of payload or fractional loopback. standard - standard loopback code. Usually consists of the repeated binary pattern of '00001' alternate - alternate loopback code. Usually the inverse of ...
ciscoICsuDsuT1StatusTable
The T1 CSU/DSU Unit Status Table. Contains information about the status of the CSU/DSU, including externally generated alarm conditions.
ciscoICsuDsuT1StatusEntry
An entry in the status table for each integrated T1 CSU/DSU.
ciscoICsuDsuT1LoopStatus
Current Loop status of T1 CSU/DSU. Represented as a sum of a bit map. The variable bit positions are: 1 - lossofSignal (LOS); unable to detect the DS1 signal. 2 - lossofFrame (LOF); unable to synchronize on the DS1 signal. 4 - detectedRemoteAlarmIndicat ...
ciscoICsuDsuT1LossOfSignals
Number of times lossofSignal event detected.
ciscoICsuDsuT1LossOfFrames
Number of times lossofFrame event detected.
ciscoICsuDsuT1RemoteAlarmIndications
Number of times RemoteAlarmIndication signal or yellow alarm received.
ciscoICsuDsuT1AlarmIndicationSignals
Number of times Alarm Indication Signal or blue alarm received.
ciscoICsuDsuSw56kConfigTable
The Switched 56k CSU/DSU Configuration Table. Contains current Sw56k CSU/DSU configuration parameters.
ciscoICsuDsuSw56kConfigEntry
An entry in the sw56k configuration table for each integrated switched 56 kbps CSU/DSU.
ciscoICsuDsuSw56kNetworkType
Configures the DSU Module for the specific type of network being used. dds - AT&T's Dataphone Digital Service, generically known as Digital Data System. Requires 4-Wire interface. att - AT&T's Switched 56 Network. Operates over 2-Wire or or 4-Wire inter ...
ciscoICsuDsuSw56kClockSource
Specifies the timing source for the DSU. 'internal' indicates timing provided by DSU. 'line' indicates timing provided by network receive signal.
ciscoICsuDsuSw56kLoopRate
The Loop Rate option selects the network loop operating speed. Only 'ciscoICsuDsuSw56kNetworkType' of 'dds' supports all listed loop rates. 'att' and 'sprint' network types only support 'bps56k' or 56 kilobits per second.
ciscoICsuDsuSw56kScramblerEnabled
Indicates if line code scrambling is enabled. Scrambling is used to prevent DTE data sequences that minic network loop maintenance functions from activating loopback. Only supported when operating in DDS mode at 64kbps (also known as clear channel mode).
ciscoICsuDsuSw56kRemoteLoopbackEnabled
Indicates if a request for Remote Digital Loopback is will be accepted.
ciscoICsuDsuSw56kLineStatusTable
The Sw56k CSU/DSU Status Table. Contains information about the status of the CSU/DSU, including externally generated alarm conditions.
ciscoICsuDsuSw56kLineStatusEntry
An entry in the sw56k status table for each integrated switched 56 kbps CSU/DSU.
ciscoICsuDsuSw56kDialingStatus
This variable indicates the dialing status of units using switched connections. idle - on-hook and no call in progress. dialing - dialing a number. onLine - Online passing data. noWinkFromSwitch - No wink from switch (cleared after 5 seconds). Wink is a ...
ciscoICsuDsuSw56kLoopStatus
Current loop status or alarm condition. Represented as a sum of a bit map. The variable bit positions are: 1 oosOofFromNetwork - The DSU is receiving Out of Service/ Out of Frame code from network indicating network trouble. This can be a problem wit ...
ciscoICsuDsuSw56kReceivedOosOofs
Number of times OOS/OOF (Out Of Sync / Out Of Frame) code received.
ciscoICsuDsuSw56kLostSealingCurrents
Number of times Lost Sealing Current.
ciscoICsuDsuSw56kLostReceiveSignals
Number of times lost receive signal.
ciscoICsuDsuSw56kLostFrameSyncs
Number of times lost frame synchronization.
ciscoICsuDsuSw56kLoopRateSearches
Number of times attempted Loop Rate Search.
ciscoICsuDsuEnableT1LoopStatusNotification
Indicates whether or not a T1 Alarm Notification will be generated by this system.
ciscoICsuDsuEnableSw56kLoopStatusNotification
Indicates whether or not a Sw56k Alarm Notification will be generated by this system.
ciscoICsuDsuMIBGroup
The collection of objects providing general information about the integrated CSU/DSU.
ciscoICsuDsuMIBT1Group
The collection of objects providing information specific to integrated T1 CSU/DSU.
ciscoICsuDsuMIBSw56kGroup
The collection of objects providing information specific to integrated Switched 56k CSU/DSU.