CISCO-IF-THRESHOLD-MIB

CISCO-IF-THRESHOLD-MIB Download

MIBs list

This MIB module defines the managed objects that support monitoring of thresholds on interfaces. Configuration and monitoring of the thresholds is done through threshold templates that can be assigned to any subset of interfaces on the network element. More than one threshold template can be assigned to a given interface. This MIB module should be used when it is desired to apply a common set of thresholds to a subset of the available interfaces. If a threshold is to be applied to only one interface, then the EVENT-MIB or the RMON-MIB may be used as simpler alternatives. If a threshold is to be applied to all available interfaces, then the EVENT-MIB may be used as a simpler alternative.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-IF-THRESHOLD-MIB

cifthTemplateIndexNext
This object contains an appropriate value to be used for cifthTemplateIndex when creating entries in the cifthTemplateTable. The distinguished value 0 indicates that no unassigned entries are available. To obtain a suggested cifthTemplateIndex value for ...
cifthTemplateLastChange
This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthTemplateTable, or an entry was created or destroyed in cifthTemplateTable. If no change to cifthTemplateTable has occurred since th ...
cifthTemplateTable
This table is used to create threshold templates. Each template includes one or more thresholds (defined in the cifthThresholdTable), and can be assigned to multiple interfaces. An interface may be associated with more than one template. The assignment ...
cifthTemplateEntry
An entry describing the general properties of a threshold template. The template is created using the cifthTemplateRowStatus object. Prior to creating an entry in the table, the manager should obtain a unique value of cifthTemplateIndex by reading the ci ...
cifthTemplateIndex
An arbitrary integer that uniquely identifies a threshold template. The value for each threshold template must remain constant at least from one re-initialization of the agent's network management system to the next re-initialization. The value may chan ...
cifthTemplateName
This object specifies a unique name associated with the threshold template by the management client, and provides a non-volatile 'handle' for the template. The name must not include whitespace characters. After this value has been written to the startup ...
cifthTemplateNotifyHoldDownType
This object specifies the method used to prevent an excess of notifications from being generated when operation fluctuates around a threshold level. The value 'holdDownTimer' indicates that notifications for a given threshold and interface are suppressed ...
cifthTemplateNotifyHoldDownTime
The minimum amount of time between successive cifthIfThresholdFired or cifthIfThresholdCleared notifications for a given interface and template. This object is instantiated only when cifthTemplateNotifyHoldDownType is set to 'holdDownTimer'.
cifthTemplateRowStatus
This object is used to create and delete threshold templates. The values of cifthTemplateName and cifthTemplateNotifyHoldDownType must be provided before activating the entry. An entry can only be deleted when there are no active entries in the cifthTempl ...
cifthThresholdLastChange
This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthThresholdTable, or an entry was created or destroyed in cifthThresholdTable. If no change to cifthThresholdTable has occurred since ...
cifthThresholdTable
This table specifies the interface thresholds used in each template.
cifthThresholdEntry
An entry specifying an interface threshold used in a threshold template. The entry is created using the cifthThresholdRowStatus object. The values of cifthThresholdObject, cifthThresholdSeverity, cifthThresholdType, and cifthThresholdFiredValue must be pr ...
cifthThresholdIndex
An arbitrary integer that uniquely identifies a threshold in a threshold template. The value for each threshold must remain constant when the agent's network management system is rebooted or re-initialized.
cifthThresholdDescr
A description of the threshold's function and use. The description must not include carriage returns.
cifthThresholdObject
The object to be compared against the threshold values. The object must be defined in a table indexed only by ifIndex. All of the instance portion of the object identifier is truncated, since the instance(s) to be compared against the threshold are identi ...
cifthThresholdSeverity
This object specifies the severity associated with the condition when the threshold is exceeded.
cifthThresholdType
The manner in which to compare cifthThresholdObject to cifthThresholdFiredValue and cifthThresholdClearedValue. The value 'absoluteValue' indicates that the value of cifthThresholdObject is to be compared directly to cifthThresholdFiredValue or cifthThres ...
cifthThresholdDirection
This object indicates which direction of movement causes the threshold to fire. The value 'rising' indicates that the threshold is fired when the current sampled value is numerically greater than or equal to the value of cifthThresholdFiredValue, and the ...
cifthThresholdFiredValue
A threshold value to check against the object identified in cifthThresholdObject. If the value of cifthThresholdDirection is 'rising', then the threshold is fired when the current sampled value (absolute, delta, or rate of increase, depending on the valu ...
cifthThresholdClearedValue
A threshold value to check against the object identified in cifthThresholdObject. If the value of cifthThresholdDirection is 'rising', then the threshold is cleared when the current sampled value (absolute, delta, or rate of increase, depending on the va ...
cifthThresholdSampleInterval
The number of milliseconds to wait between samples of the object identified in cifthThresholdObject. To encourage consistency in sampling, the interval is measured from the beginning of one check to the beginning of the next and the timer is restarted im ...
cifthThresholdApsSwitchover
This object indicates whether automatic protection switching (APS) switchover should be triggered, if applicable, when the threshold is fired. The value of this object takes effect when the template identified by cifthTemplateIndex is assigned to an inte ...
cifthThresholdRowStatus
This object is used to create and delete thresholds in templates. A new entry can only be created when there is an active entry in the cifthTemplateTable with the same value of cifthTemplateIndex. The values of cifthThresholdObject, cifthThresholdSeverit ...
cifthTemplateIfLastChange
This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthTemplateIfAssignTable, or an entry was created or destroyed in cifthTemplateIfAssignTable. If no change to cifthTemplateIfAssignTab ...
cifthTemplateIfAssignTable
This table specifies the assignment of threshold templates to specific interfaces. Each threshold template may be assigned to multiple interfaces. Each interface may have multiple threshold templates assigned to it.
cifthTemplateIfAssignEntry
An entry describing the assignment of a particular threshold template to a particular interface. The entry is created using the cifthTemplateIfAssignRowStatus object.
cifthTemplateIfAssignInterface
This object identifies an interface to which the template is assigned.
cifthTemplateIfAssignOperStatus
This object indicates whether the threshold template identified by cifthTemplateIndex is operational on the interface identified by cifthTemplateIfAssignInterface. When the value of this object is 'up', this indicates that the thresholds in this template ...
cifthTemplateIfAssignRowStatus
This object is used to create and delete entries in the table, assigning templates to interfaces and removing templates from interfaces, respectively. A new entry can only be created when there is an active entry in the cifthTemplateTable with the same va ...
cifthThresholdFiredNotifyEnable
This object specifies the minimum severity threshold governing the generation of cifthIfThresholdFired and cifthIfThresholdCleared notifications. For example, if the value of this object is set to 'degrade', then the agent generates these notifications i ...
cifthThresholdFiredLastChange
This object specifies the value of sysUpTime at the last time there was either a change to any object in any entry in cifthIfThresholdFiredTable, or an entry was added or deleted in cifthIfThresholdFiredTable. If no change to cifthIfThresholdFiredTable h ...
cifthIfThresholdFiredTable
This table indicates the interfaces that currently have threshold fired conditions.
cifthIfThresholdFiredEntry
An entry indicating an interface that currently has one or more threshold fired conditions based on one template.
cifthIfThresholdFiredTemplate
This object specifies a template for which one or more of the thresholds are fired on this interface.
cifthIfThresholdsFired
This object specifies those thresholds that are currently being exceeded on this interface. If a threshold is currently being exceeded (i.e., the threshold is fired) on the interface, then the corresponding bit in the threshold list is set to one. Otherw ...
cifthIfLastThresholdFired
This object specifies the last threshold fired or cleared on the interface.
cifthIfThresholdFiredLstChange
This object specifies the value of sysUpTime at the last time a threshold was fired or cleared on the interface.
cifthIfThresholdFiredLstSeverity
This object specifies the severity of the threshold that was last fired or cleared on the interface.
cifthIfThresholdFiredMaxSeverity
This object specifies the highest severity among the thresholds that are currently being exceeded on this interface.
cIfThresholdTemplateGroup
A collection of mandatory managed objects for configuration of threshold templates.
cIfThresholdFiredGroup
A collection of mandatory managed objects for monitoring interfaces where thresholds have been exceeded.
cifthHoldDownTimerGroup
A collection of managed objects for configuration of a timer-based mechanism for suppression of excess notifications in a short time interval.
cifthHoldDownHysteresisGroup
A collection of managed objects for configuration of threshold values used to assert that the threshold is no longer being exceeded. These objects are part of the hysteresis mechanism used to prevent excess notifications in a short time interval.
cifthApsGroup
A collection of managed objects for configuration of APS switchover triggers based on interface thresholds.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.