CISCO-OPTICAL-MONITOR-MIB

CISCO-OPTICAL-MONITOR-MIB Download

MIBs list

This MIB module defines objects to monitor optical characteristics and set corresponding thresholds on the optical interfaces in a network element.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-OPTICAL-MONITOR-MIB

cOpticalMonTable
This table provides objects to monitor optical parameters in a network element. It also provides objects for setting high and low threshold levels, with configurable severities, on these monitored parameters.
cOpticalMonEntry
An entry in the cOpticalMonTable provides objects to monitor an optical parameter and set threshold levels on that parameter, at an optical interface. Note that the set of monitored optical parameters may vary based on interface type, direction, and monit ...
cOpticalMonDirection
This object indicates the direction monitored for the optical interface, in this entry.
cOpticalMonLocation
This object indicates whether the optical characteristics are measured before or after adjustment (e.g. optical amplification or attenuation), at this interface.
cOpticalMonParameterType
This object specifies the optical parameter that is being monitored in this entry.
cOpticalParameterValue
This object gives the value measured for the particular optical parameter specified by the cOpticalMonParameterType object.
cOpticalParamHighAlarmThresh
This object is used to set a high alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by cOpticalParameterValue goes from below the value configured in this object to above the value configured in ...
cOpticalParamHighAlarmSev
This object is used to specify a severity level associated with the high alarm threshold given by the cOpticalParamHighAlarmThresh object. The values 'notAlarmed', 'notReported', and 'cleared' do not apply. The severity level configured in this object mus ...
cOpticalParamHighWarningThresh
This object is used to set a high warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by cOpticalParameterValue goes from below the value configured in this object to above the va ...
cOpticalParamHighWarningSev
This object is used to specify a severity level associated with the high warning threshold given by the cOpticalParamHighWarningThresh object. The values 'critical', 'major', and 'cleared' do not apply. The severity level configured in this object must be ...
cOpticalParamLowAlarmThresh
This object is used to set a low alarm threshold on the optical parameter being monitored. An alarm condition will be raised if the value given by cOpticalParameterValue goes from above the value configured in this object to below the value configured in ...
cOpticalParamLowAlarmSev
This object is used to specify a severity level associated with the low alarm threshold given by the cOpticalParamLowAlarmThresh object. The values 'notAlarmed', 'notReported', and 'cleared' do not apply. The severity level configured in this object must ...
cOpticalParamLowWarningThresh
This object is used to set a low warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by cOpticalParameterValue goes from above the value configured in this object to below the val ...
cOpticalParamLowWarningSev
This object is used to specify a severity level associated with the low warning threshold given by the cOpticalParamLowWarningThresh object. The values 'critical', 'major', and 'cleared' do not apply. The severity level configured in this object must be l ...
cOpticalParamAlarmStatus
This object is used to indicate the current status of the thresholds for the monitored optical parameter on the interface. If a threshold is currently being exceeded on the interface, the corresponding bit in this object will be set to 1. Otherwise, the b ...
cOpticalParamAlarmCurMaxThresh
This object indicates the threshold value of the highest severity threshold that is currently being exceeded on the interface, for the optical parameter. If no threshold value is currently being exceeded, then the value '-1000000' is returned.
cOpticalParamAlarmCurMaxSev
This object indicates the maximum severity of any thresholds that are currently being exceeded on the interface, for the optical parameter.
cOpticalParamAlarmLastChange
This object specifies the value of sysUpTime at the last time a threshold related to a particular optical parameter was exceeded or cleared on the interface.
cOpticalMon15MinValidIntervals
This object gives the number of previous 15 minute intervals for which valid performance monitoring data has been stored on the interface. The value of this object will be n (where n is the maximum number of 15 minute intervals supported at this interface ...
cOpticalMon24HrValidIntervals
This object gives the number of previous 24 hour intervals for which valid performance monitoring data has been stored on the interface. The value of this object will be 0 if the measurement was (re-)started within the last 24 hours, or 1 otherwise.
cOpticalParamThreshSource
This object indicates if the current value of a particular threshold in this entry is user configured value or it is a system default value. It also allows user to specify the list of thresholds for this entry which should be restored to their system defa ...
cOpticalNotifyEnable
This object specifies the minimum severity threshold governing the generation of cOpticalMonParameterStatus notifications. For example, if the value of this object is set to 'major', then the agent generates these notifications if and only if the severity ...
cOpticalMonEnable
This object specifies the types of transceivers for which optical monitoring is enabled. A value of 1 for the bit 'all', specifies that optical monitoring functionality is enabled for all the types of transceivers which are supported by system and have op ...
cOpticalMonPollInterval
This object specifies the interval in minutes after which optical transceiver data will be polled by system repeatedly and updated in cOpticalMonTable when one or more bits in cOpticalMonEnable is set.
cOpticalMonIfTable
This table contains the list of optical interfaces populated in cOpticalMonTable.
cOpticalMonIfEntry
An entry containing the information for a particular optical interface.
cOpticalMonIfTimeInSlot
This object indicates when this optical transceiver was detected by the system.
cOpticalPMCurrentTable
This table contains performance monitoring data for the various optical parameters, collected over the current 15 minute or the current 24 hour interval.
cOpticalPMCurrentEntry
An entry in the cOpticalPMCurrentTable. It contains performance monitoring data for a monitored optical parameter at an interface, collected over the current 15 minute or the current 24 hour interval. Note that the set of monitored optical parameters may ...
cOpticalPMCurrentPeriod
This object indicates whether the optical parameter values given in this entry are collected over the current 15 minute or the current 24 hour interval.
cOpticalPMCurrentDirection
This object indicates the direction monitored for the optical interface, in this entry.
cOpticalPMCurrentLocation
This object indicates whether the optical characteristics are measured before or after adjustment (e.g. optical amplification or attenuation), at this interface.
cOpticalPMCurrentParamType
This object specifies the optical parameter that is being monitored, in this entry.
cOpticalPMCurrentMaxParam
This object gives the maximum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval.
cOpticalPMCurrentMinParam
This object gives the minimum value measured for the monitored optical parameter, in the current 15 minute or the current 24 hour interval.
cOpticalPMCurrentMeanParam
This object gives the average value of the monitored optical parameter, in the current 15 minute or the current 24 hour interval.
cOpticalPMCurrentUnavailSecs
This object is used to indicate the number of seconds, in the current 15 minute or the current 24 hour interval, for which the optical performance data is not accounted for. In the receive direction, the performance data could be unavailable during these ...
cOpticalPMIntervalTable
This table stores performance monitoring data for the various optical parameters, collected over previous intervals. This table can have entries for one complete 24 hour interval and up to 96 complete 15 minute intervals. A system is required to store at ...
cOpticalPMIntervalEntry
An entry in the cOpticalPMIntervalTable. It contains performance monitoring data for an optical parameter, collected over a previous interval. Note that the set of monitored optical parameters may vary based on interface type, direction, and monitoring lo ...
cOpticalPMIntervalPeriod
This object indicates whether the optical parameter values, given in this entry, are collected over a period of 15 minutes or 24 hours.
cOpticalPMIntervalNumber
A number between 1 and 96, which identifies the interval for which the set of optical parameter values is available. The interval identified by 1 is the most recently completed 15 minute or 24 hour interval, and the interval identified by N is the interva ...
cOpticalPMIntervalDirection
This object indicates the direction monitored for the optical interface, in this entry.
cOpticalPMIntervalLocation
This object indicates whether the optical characteristics are measured before or after adjustment (e.g. optical amplification or attenuation), at this interface.
cOpticalPMIntervalParamType
This object specifies the optical parameter that is being monitored, in this entry.
cOpticalPMIntervalMaxParam
This object gives the maximum value measured for the optical parameter, in a particular 15 minute or 24 hour interval.
cOpticalPMIntervalMinParam
This object gives the minimum value measured for the optical parameter, in a particular 15 minute or 24 hour interval.
cOpticalPMIntervalMeanParam
This object gives the average value of the measured optical parameter, in a particular 15 minute or 24 hour interval.
cOpticalPMIntervalUnavailSecs
This object is used to indicate the number of seconds, in the particular 15 minute or 24 hour interval, for which the optical performance data is not accounted for. In the receive direction, the performance data could be unavailable during these periods f ...
cOpticalMIBMonGroup
A mandatory object that provides monitoring of optical characteristics.
cOpticalMIBThresholdGroup
A collection of objects that support thresholds on optical parameters and provide status information when the thresholds are exceeded or cleared.
cOpticalMIBSeverityGroup
A collection of objects that support severities for thresholds on optical parameters.
cOpticalMIBPMGroup
A collection of objects that provide optical performance monitoring data for 15 minute and 24 hour intervals.
cOpticalMIBNotifyEnableGroup
An object to control the generation of notifications.
cOpticalMonIfTimeGroup
A collection of object(s) that provide time related information for transceivers in the system.
cOpticalMIBEnableConfigGroup
A collection of object(s) to enable/disable optical monitoring.
cOpticalMIBIntervalConfigGroup
A collection of object(s) to specify polling interval for monitoring optical transceivers.
cOpticalMonThreshSourceGroup
A collection of object(s) to restore a given threshold to its default value.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.

MIBs list