CPQCR

CPQCR Download

MIBs list

Compaq CR3500 RAID Controller information

With the IPHost SNMP tool, you can monitor any SNMP objects of the CPQCR . You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the CPQCR .

OID list for CPQCR

cpqCrMibRevMajor
The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the support ...
cpqCrMibRevMinor
The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
cpqCrMibCondition
The overall condition (status) of the system represented by this MIB.
cpqCrOsCommonPollFreq
The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management stat ...
cpqCrCntlrTable
Compaq Clustered RAID Array Controller Table.
cpqCrCntlrEntry
Compaq Clustered RAID Array Controller Entry.
cpqCrCntlrIndex
Compaq Clustered RAID Array Controller Index. This value is a logical number whose meaning is OS dependent. Each physical controller has one unique controller number associated with it.
cpqCrCntlrSerialNumber
Compaq CR3500 Controller Serial Number.
cpqCrCntlrFWRev
Compaq Clustered RAID Array Controller Firmware Revision. The firmware revision of the Compaq Clustered RAID Controller. This value can be used to help identify a particular revision of the controller.
cpqCrCntlrCondition
The condition of the device. This value represents the overall condition of this controller, and any associated logical drives, physical drives, and array accelerators.
cpqCrCntlrCurrentRole
Compaq Clustered RAID Array Controller Current Role. For duplexed array controllers, this is the controllers current role. The following values are valid: other (1) Indicates that the instrument agent does not recognize the role of the controller. You m ...
cpqCrCntlrDriveOwnership
Compaq Clustered RAID Array Controller Drive Ownership. For duplexed controllers, indicates to which controller slot the shared devices are associated. The following values are valid: other (1) Indicates that the instrument agent does not recognize the st ...
cpqCrCntlrRebuildRate
Compaq Clustered RAID Array Controller Rebuild Rate. Determines the rate at which disks are to be rebuilt if there is I/O activity. 1 = Minimum rate 100 = Maximum rate
cpqCrCntlrCreateRate
Compaq Clustered RAID Array Controller Create Rate. Determines the rate at which RAIDsets are to be created if there is I/O activity. 1 = Minimum rate 100 = maximum rate
cpqCrCntlrCacheSize
Compaq Clustered RAID Array Controller Cache Size. Size of the controller's cache in MB.
cpqCrCntlrSimmSizeA
Compaq Clustered RAID Array Controller Memory Module Size. Size of the memory module in slot A in MB.
cpqCrCntlrSimmSizeB
Compaq Clustered RAID Array Controller Memory Module Size. Size of the memory module in slot B in MB.
cpqCrLogDrvTable
Compaq Clustered RAID RAIDset Table. A table of RAIDset entries.
cpqCrLogDrvEntry
Compaq Clustered RAID RAIDset Entry. A RAIDset entry.
cpqCrLogDrvCntlrIndex
Compaq Clustered RAID RAIDset Controller Index. This maps the RAIDsets into their respective controllers. Controller index 'i' under the controller group owns the associated drives in the RAIDset which use that index.
cpqCrLogDrvIndex
Compaq Clustered RAID RAIDset Index. This logical drive number keeps track of multiple instances of logical drives which are on the same controller. For each controller index value, the logical drive index starts at 1 and increments for each logical driv ...
cpqCrLogDrvRAIDLevel
RAID Level. This shows the RAID level of the RAIDset. To change the RAID level, run the Compaq CL1850 Array Configuration Utility. The following values are valid for the RAIDset RAID Level: JBOD (2) Just a Bunch of Drives. Fault tolerance is not enabled. ...
cpqCrLogDrvStatus
RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduced (3) Indicates that the RAIDset is operating in a degraded or reduced state. One or more of the physical disks which make u ...
cpqCrLogDrvRebuildPercentage
RAIDset Rebuild Percentage Complete. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how far the rebuild process has progressed as a percentage. When the value reaches 100, the rebuilding p ...
cpqCrLogDrvAvailSpares
RAIDset Available Spares. This indicates if this RAIDset has one or more spares designated for it that are not currently in use by another drive. Each octet present will be a physical drive ID that is an available spare for this logical drive. These are ...
cpqCrLogDrvSize
RAIDset Size. This is the size of the RAIDset in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may diffe ...
cpqCrLogDrvPhyDrvIDs
RAIDset Physical Drive IDs. This lists the physical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into the physical drive table. Each byte of the string is an index.
cpqCrLogDrvCondition
RAIDset condition. This value represents the overall condition of this RAIDset and any associated physical drives.
cpqCrLogDrvPartitionIDs
RAIDset Logical Drive IDs. This lists the logical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into the logical drive table. Each byte of the string is an index.
cpqCrSpareTable
Compaq Clustered RAID Spare Table. A table of spare entries.
cpqCrSpareEntry
Compaq Clustered RAID Spare Entry. An entry in the spare table.
cpqCrSpareCntlrIndex
Spare Controller Index. This index maps the spare drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqCrSparePhyDrvIndex
Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with the physical drive table.
cpqCrSpareStatus
Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Hot Spare(5) The drive attached to this channel is kept spinning whenever the controller is powered up and it is to be automatically broug ...
cpqCrSpareCondition
Spare Drive condition. This value represents the overall condition of this spare drive and any associated physical drives.
cpqCrSpareScsiID
SCSI ID. This value represents the SCSI identifier of this spare drive.
cpqCrPhyDrvTable
Compaq Clustered RAID Physical Drive Table. A table of physical drive entries.
cpqCrPhyDrvEntry
Compaq Clustered RAID Physical Drive Entry. A physical drive entry.
cpqCrPhyDrvCntlrIndex
Compaq Clustered RAID Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
cpqCrPhyDrvIndex
Compaq Clustered RAID Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the cpqCrPhyDrvCntlrIndex uniquely identify a specific physical drive.
cpqCrPhyDrvVendor
Physical Drive Vendor. This is the name of the manufacturer of the physical drive. This value is based upon the vendor name as returned by the SCSI inquiry command but may have been modified due to space limitations. This can be used for identification p ...
cpqCrPhyDrvModel
Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. For example, you might see: CP3201. If a drive fails, note the model to identify the type of drive ...
cpqCrPhyDrvRevision
Physical Drive Revision. This shows the physical drive revision number.
cpqCrPhyDrvStatus
Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status: Offline (3) The drive attached to this channel is not a member of the RAID set. Online (4) The drive attached to this channel ...
cpqCrPhyDrvSize
Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so ...
cpqCrPhyDrvCondition
Physical Drive condition. This value represents the overall condition of this physical drive.
cpqCrPhyDrvScsiID
SCSI ID. This value represents the SCSI identifier of this physical drive.
cpqCrEMUBoardTemperatureStatus
Environmental Monitoring Unit (EMU) Board Temperature status. The System Board Temperature status as determined by the EMU is: Not Installed (2) The board temperature can not be detected in the unit. Normal (3) The board temperature detected by the EMU is ...
cpqCrEMUEnclosureTemperatureStatus
Environmental Monitoring Unit (EMU) Enclosure Temperature status. The Enclosure Housing Temperature status as determined by the EMU is: Not Installed (2) The enclosure temperature can not be detected in the unit. Normal (3) The enclosure temperature detec ...
cpqCrEMUBoardTemperatureLevel
Environmental Monitoring Unit (EMU) Board Temperature. Indicates the System Board temperature in degrees Fahrenheit.
cpqCrEMUEnclosureTemperatureLevel
Environmental Monitoring Unit (EMU) Enclosure Temperature. Indicates the Enclosure Housing temperature in degrees Fahrenheit.
cpqCrEMUCondition
Primary enclosure condition. This value represents the overall condition of the primary enclosure.
cpqCrEMUFanStatus
Primary enclosure fan status. The primary enclosure fan status is: OK (2) Status is normal. Critical (3) Fan has failed. Unknown (4) Information unavailable.
cpqCrEMUFanCondition
Primary enclosure fan condition. This value represents the overall condition of the fan in the primary enclosure.
cpqCrEMUPowerSupplyStatus
Primary enclosure power supply status. The primary enclosure power supply status is: OK (2) Status is normal. Critical (3) Power supply is installed and marked as failed. Not Installed (4) One of the redundant power supplies has been removed. Unknown (5) ...
cpqCrEMUPowerSupplyCondition
Primary enclosure power supply condition. This value represents the overall condition of the power supply in the primary enclosure.
cpqCrEMUTemperatureStatus
Primary enclosure temperature status. The primary enclosure temperature status is: OK (2) Status is normal. Critical (3) Controller temperature sensor has detected a critical temperature condition in the primary enclosure. Non-critical (4) Controller temp ...
cpqCrEMUTemperatureLevel
Primary enclosure temperature. Indicates the temperature within the primary enclosure in degrees Celsius.
cpqCrEMUTemperatureCondition
Primary enclosure temperature condition. This value represents the overall condition of the temperature in the primary enclosure.
cpqCrExpCabPowerSupplyStatus
Expansion Cabinet power supply status. The expansion cabinet power supply status is: OK (2) Status is normal. Either redundant power supplies are installed and reporting no error or a single power supply is installed. Non-Critical (3) Redundant power supp ...
cpqCrExpCabFanStatus
Expansion Cabinet fan status. The expansion cabinet fan status is: OK (2) Status is normal. One or more fans is installed and no error is reported. Non-Critical (4) Fan degraded condition. One or more fans are reporting an error or only one fan is install ...
cpqCrExpCabTemperatureStatus
Expansion Cabinet temperature status. The expansion cabinet temperature status is: OK (2) Status is normal. Critical (3) Critical temperature condition reported. Non-Critical (4) Warning temperature condition reported. Not Installed (5) Temperature valid ...
cpqCrExpCabCondition
Expansion Cabinet condition. This value represents the overall condition of the expansion cabinet.
cpqCrExpCabPowerSupplyCondition
Expansion Cabinet power supply condition. This value represents the overall condition of the power supply in the expansion cabinet.
cpqCrExpCabFanCondition
Expansion Cabinet fan condition. This value represents the overall condition of the fan in the expansion cabinet.
cpqCrExpCabTemperatureCondition
Expansion Cabinet temperature condition. This value represents the overall condition of the temperature in the expansion cabinet.
cpqCrPartitionTable
Compaq Clustered RAID Logical Drive Table. A table of logical drive entries.
cpqCrPartitionEntry
Compaq Clustered RAID Logical Drive Entry. A Logical Drive entry.
cpqCrPartitionLogDrvIndex
Compaq Clustered RAID Logical Drive Index. This maps the logical drives into their respective RAIDsets. RAIDset index 'i' under the RAIDset group owns the associated drives in the logical drives which use that index.
cpqCrPartitionIndex
Compaq Clustered RAID Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are part of the same RAIDset. For each RAIDset index value, the logical drive index starts at 1 and increments for each logical ...
cpqCrPartitionRAIDLevel
Logical Drive RAID Level. This shows the RAID level of the logical drive. To change the RAID level, run the Compaq CR3500 Array Configuration Utility. The following values are valid for the logical drive RAID Level: JBOD (2) Just a Bunch of Drives. Fault ...
cpqCrPartitionStatus
Logical Drive Status. The logical drive can be in one of the following states: Good (2) Indicates that the logical drive is fully operational. Reduced (3) Indicates that the logical drive is operating in a degraded or reduced state. One or more of the phy ...
cpqCrPartitionSize
Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this val ...
cpqCrPartitionCondition
Logical drive condition. This value represents the overall condition of this logical drive and any associated physical drives.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now. Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access. The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.

MIBs list