CPQCR Download
Compaq CR3500 RAID Controller information
With the IPHost SNMP tool, you can monitor any SNMP objects of the
CPQCR
. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables,
their current values and descriptions taken from the
CPQCR
.
OID list for CPQCR
- cpqCrMibRevMajor
- The Major Revision level. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of the support ...
- cpqCrMibRevMinor
- The Minor Revision level. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
- cpqCrMibCondition
- The overall condition (status) of the system represented by this MIB.
- cpqCrOsCommonPollFreq
- The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management stat ...
- cpqCrCntlrTable
- Compaq Clustered RAID Array Controller Table.
- cpqCrCntlrEntry
- Compaq Clustered RAID Array Controller Entry.
- cpqCrCntlrIndex
- Compaq Clustered RAID Array Controller Index. This value is a logical number whose meaning is OS dependent. Each physical controller has one unique controller number associated with it.
- cpqCrCntlrSerialNumber
- Compaq CR3500 Controller Serial Number.
- cpqCrCntlrFWRev
- Compaq Clustered RAID Array Controller Firmware Revision. The firmware revision of the Compaq Clustered RAID Controller. This value can be used to help identify a particular revision of the controller.
- cpqCrCntlrCondition
- The condition of the device. This value represents the overall condition of this controller, and any associated logical drives, physical drives, and array accelerators.
- cpqCrCntlrCurrentRole
- Compaq Clustered RAID Array Controller Current Role. For duplexed array controllers, this is the controllers current role. The following values are valid: other (1) Indicates that the instrument agent does not recognize the role of the controller. You m ...
- cpqCrCntlrDriveOwnership
- Compaq Clustered RAID Array Controller Drive Ownership. For duplexed controllers, indicates to which controller slot the shared devices are associated. The following values are valid: other (1) Indicates that the instrument agent does not recognize the st ...
- cpqCrCntlrRebuildRate
- Compaq Clustered RAID Array Controller Rebuild Rate. Determines the rate at which disks are to be rebuilt if there is I/O activity. 1 = Minimum rate 100 = Maximum rate
- cpqCrCntlrCreateRate
- Compaq Clustered RAID Array Controller Create Rate. Determines the rate at which RAIDsets are to be created if there is I/O activity. 1 = Minimum rate 100 = maximum rate
- cpqCrCntlrCacheSize
- Compaq Clustered RAID Array Controller Cache Size. Size of the controller's cache in MB.
- cpqCrCntlrSimmSizeA
- Compaq Clustered RAID Array Controller Memory Module Size. Size of the memory module in slot A in MB.
- cpqCrCntlrSimmSizeB
- Compaq Clustered RAID Array Controller Memory Module Size. Size of the memory module in slot B in MB.
- cpqCrLogDrvTable
- Compaq Clustered RAID RAIDset Table. A table of RAIDset entries.
- cpqCrLogDrvEntry
- Compaq Clustered RAID RAIDset Entry. A RAIDset entry.
- cpqCrLogDrvCntlrIndex
- Compaq Clustered RAID RAIDset Controller Index. This maps the RAIDsets into their respective controllers. Controller index 'i' under the controller group owns the associated drives in the RAIDset which use that index.
- cpqCrLogDrvIndex
- Compaq Clustered RAID RAIDset Index. This logical drive number keeps track of multiple instances of logical drives which are on the same controller. For each controller index value, the logical drive index starts at 1 and increments for each logical driv ...
- cpqCrLogDrvRAIDLevel
- RAID Level. This shows the RAID level of the RAIDset. To change the RAID level, run the Compaq CL1850 Array Configuration Utility. The following values are valid for the RAIDset RAID Level: JBOD (2) Just a Bunch of Drives. Fault tolerance is not enabled. ...
- cpqCrLogDrvStatus
- RAIDset Status. The RAIDset can be in one of the following states: Good (2) Indicates that the RAIDset is fully operational. Reduced (3) Indicates that the RAIDset is operating in a degraded or reduced state. One or more of the physical disks which make u ...
- cpqCrLogDrvRebuildPercentage
- RAIDset Rebuild Percentage Complete. After a failed physical drive has been replaced, the physical drive must have its data rebuilt. This value shows how far the rebuild process has progressed as a percentage. When the value reaches 100, the rebuilding p ...
- cpqCrLogDrvAvailSpares
- RAIDset Available Spares. This indicates if this RAIDset has one or more spares designated for it that are not currently in use by another drive. Each octet present will be a physical drive ID that is an available spare for this logical drive. These are ...
- cpqCrLogDrvSize
- RAIDset Size. This is the size of the RAIDset in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may diffe ...
- cpqCrLogDrvPhyDrvIDs
- RAIDset Physical Drive IDs. This lists the physical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into the physical drive table. Each byte of the string is an index.
- cpqCrLogDrvCondition
- RAIDset condition. This value represents the overall condition of this RAIDset and any associated physical drives.
- cpqCrLogDrvPartitionIDs
- RAIDset Logical Drive IDs. This lists the logical drive IDs which are associated with this RAIDset. These are the same IDs which can be used as indices into the logical drive table. Each byte of the string is an index.
- cpqCrSpareTable
- Compaq Clustered RAID Spare Table. A table of spare entries.
- cpqCrSpareEntry
- Compaq Clustered RAID Spare Entry. An entry in the spare table.
- cpqCrSpareCntlrIndex
- Spare Controller Index. This index maps the spare drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
- cpqCrSparePhyDrvIndex
- Physical Drive Index. This index maps the spare to the physical drive it represents. The value of this index is the same as the one used with the physical drive table.
- cpqCrSpareStatus
- Spare Status. This shows the status of the on-line spare drive. The following values are valid for the spare status: Hot Spare(5) The drive attached to this channel is kept spinning whenever the controller is powered up and it is to be automatically broug ...
- cpqCrSpareCondition
- Spare Drive condition. This value represents the overall condition of this spare drive and any associated physical drives.
- cpqCrSpareScsiID
- SCSI ID. This value represents the SCSI identifier of this spare drive.
- cpqCrPhyDrvTable
- Compaq Clustered RAID Physical Drive Table. A table of physical drive entries.
- cpqCrPhyDrvEntry
- Compaq Clustered RAID Physical Drive Entry. A physical drive entry.
- cpqCrPhyDrvCntlrIndex
- Compaq Clustered RAID Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached. The value of this index is the same as the one used under the controller group.
- cpqCrPhyDrvIndex
- Compaq Clustered RAID Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the cpqCrPhyDrvCntlrIndex uniquely identify a specific physical drive.
- cpqCrPhyDrvVendor
- Physical Drive Vendor. This is the name of the manufacturer of the physical drive. This value is based upon the vendor name as returned by the SCSI inquiry command but may have been modified due to space limitations. This can be used for identification p ...
- cpqCrPhyDrvModel
- Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. For example, you might see: CP3201. If a drive fails, note the model to identify the type of drive ...
- cpqCrPhyDrvRevision
- Physical Drive Revision. This shows the physical drive revision number.
- cpqCrPhyDrvStatus
- Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status: Offline (3) The drive attached to this channel is not a member of the RAID set. Online (4) The drive attached to this channel ...
- cpqCrPhyDrvSize
- Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so ...
- cpqCrPhyDrvCondition
- Physical Drive condition. This value represents the overall condition of this physical drive.
- cpqCrPhyDrvScsiID
- SCSI ID. This value represents the SCSI identifier of this physical drive.
- cpqCrEMUBoardTemperatureStatus
- Environmental Monitoring Unit (EMU) Board Temperature status. The System Board Temperature status as determined by the EMU is: Not Installed (2) The board temperature can not be detected in the unit. Normal (3) The board temperature detected by the EMU is ...
- cpqCrEMUEnclosureTemperatureStatus
- Environmental Monitoring Unit (EMU) Enclosure Temperature status. The Enclosure Housing Temperature status as determined by the EMU is: Not Installed (2) The enclosure temperature can not be detected in the unit. Normal (3) The enclosure temperature detec ...
- cpqCrEMUBoardTemperatureLevel
- Environmental Monitoring Unit (EMU) Board Temperature. Indicates the System Board temperature in degrees Fahrenheit.
- cpqCrEMUEnclosureTemperatureLevel
- Environmental Monitoring Unit (EMU) Enclosure Temperature. Indicates the Enclosure Housing temperature in degrees Fahrenheit.
- cpqCrEMUCondition
- Primary enclosure condition. This value represents the overall condition of the primary enclosure.
- cpqCrEMUFanStatus
- Primary enclosure fan status. The primary enclosure fan status is: OK (2) Status is normal. Critical (3) Fan has failed. Unknown (4) Information unavailable.
- cpqCrEMUFanCondition
- Primary enclosure fan condition. This value represents the overall condition of the fan in the primary enclosure.
- cpqCrEMUPowerSupplyStatus
- Primary enclosure power supply status. The primary enclosure power supply status is: OK (2) Status is normal. Critical (3) Power supply is installed and marked as failed. Not Installed (4) One of the redundant power supplies has been removed. Unknown (5) ...
- cpqCrEMUPowerSupplyCondition
- Primary enclosure power supply condition. This value represents the overall condition of the power supply in the primary enclosure.
- cpqCrEMUTemperatureStatus
- Primary enclosure temperature status. The primary enclosure temperature status is: OK (2) Status is normal. Critical (3) Controller temperature sensor has detected a critical temperature condition in the primary enclosure. Non-critical (4) Controller temp ...
- cpqCrEMUTemperatureLevel
- Primary enclosure temperature. Indicates the temperature within the primary enclosure in degrees Celsius.
- cpqCrEMUTemperatureCondition
- Primary enclosure temperature condition. This value represents the overall condition of the temperature in the primary enclosure.
- cpqCrExpCabPowerSupplyStatus
- Expansion Cabinet power supply status. The expansion cabinet power supply status is: OK (2) Status is normal. Either redundant power supplies are installed and reporting no error or a single power supply is installed. Non-Critical (3) Redundant power supp ...
- cpqCrExpCabFanStatus
- Expansion Cabinet fan status. The expansion cabinet fan status is: OK (2) Status is normal. One or more fans is installed and no error is reported. Non-Critical (4) Fan degraded condition. One or more fans are reporting an error or only one fan is install ...
- cpqCrExpCabTemperatureStatus
- Expansion Cabinet temperature status. The expansion cabinet temperature status is: OK (2) Status is normal. Critical (3) Critical temperature condition reported. Non-Critical (4) Warning temperature condition reported. Not Installed (5) Temperature valid ...
- cpqCrExpCabCondition
- Expansion Cabinet condition. This value represents the overall condition of the expansion cabinet.
- cpqCrExpCabPowerSupplyCondition
- Expansion Cabinet power supply condition. This value represents the overall condition of the power supply in the expansion cabinet.
- cpqCrExpCabFanCondition
- Expansion Cabinet fan condition. This value represents the overall condition of the fan in the expansion cabinet.
- cpqCrExpCabTemperatureCondition
- Expansion Cabinet temperature condition. This value represents the overall condition of the temperature in the expansion cabinet.
- cpqCrPartitionTable
- Compaq Clustered RAID Logical Drive Table. A table of logical drive entries.
- cpqCrPartitionEntry
- Compaq Clustered RAID Logical Drive Entry. A Logical Drive entry.
- cpqCrPartitionLogDrvIndex
- Compaq Clustered RAID Logical Drive Index. This maps the logical drives into their respective RAIDsets. RAIDset index 'i' under the RAIDset group owns the associated drives in the logical drives which use that index.
- cpqCrPartitionIndex
- Compaq Clustered RAID Logical Drive Index. This logical drive number keeps track of multiple instances of logical drives which are part of the same RAIDset. For each RAIDset index value, the logical drive index starts at 1 and increments for each logical ...
- cpqCrPartitionRAIDLevel
- Logical Drive RAID Level. This shows the RAID level of the logical drive. To change the RAID level, run the Compaq CR3500 Array Configuration Utility. The following values are valid for the logical drive RAID Level: JBOD (2) Just a Bunch of Drives. Fault ...
- cpqCrPartitionStatus
- Logical Drive Status. The logical drive can be in one of the following states: Good (2) Indicates that the logical drive is fully operational. Reduced (3) Indicates that the logical drive is operating in a degraded or reduced state. One or more of the phy ...
- cpqCrPartitionSize
- Logical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this val ...
- cpqCrPartitionCondition
- Logical drive condition. This value represents the overall condition of this logical drive and any associated physical drives.
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.
Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access.
The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.