CPQUPS Download
Compaq Uninterruptible Power Supply (UPS) information
With the IPHost SNMP tool, you can monitor any SNMP objects of the
CPQUPS.
You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables, their current values and descriptions taken from the
CPQUPS
.
OID list for CPQUPS
- cpqUpsMibRevMajor
- The Major Revision level of the MIB. A change in the major revision level represents a major change in the architecture of the MIB. A change in the major revision level may indicate a significant change in the information supported and/or the meaning of ...
- cpqUpsMibRevMinor
- The Minor Revision level of the MIB. A change in the minor revision level may represent some minor additional support, no changes to any pre-existing information has occurred.
- cpqUpsMibCondition
- The overall condition. This object represents the overall status of the UPS system represented by this MIB.
- cpqUpsOsCommonPollFreq
- The Insight Agent's polling frequency. The frequency, in seconds, at which the Insight Agent requests information from the device driver. A frequency of zero (0) indicates that the Insight Agent retrieves the information upon request of a management stat ...
- cpqUpsOsCommonModuleTable
- A table of software modules/ that provide an interface to the device this MIB describes.
- cpqUpsOsCommonModuleEntry
- A description of a software module that provides an interface to the device this MIB describes.
- cpqUpsOsCommonModuleIndex
- A unique index for this module description.
- cpqUpsOsCommonModuleName
- The module name.
- cpqUpsOsCommonModuleVersion
- The module version in XX.YY format. Where XX is the major version number and YY is the minor verion number. This field will be a null (size 0) string if the agent cannot provide the module version.
- cpqUpsOsCommonModuleDate
- The module date. field octets contents range ===== ====== ======= ===== 1 1-2 year 0..65536 2 3 month 1..12 3 4 day 1..31 4 ...
- cpqUpsOsCommonModulePurpose
- The purpose of the module described in this entry.
- cpqUpsLineStatus
- The status of the AC line input to the UPS.
- cpqUpsName
- The UPS name (type).
- cpqUpsEstimatedBatteryLife
- The estimated time, in minutes, of battery power available. The value will be negative one (-1) if the agent is unable to determine this information. A UPS may not provide this information when AC power is available.
- cpqUpsAutoShutdownDelay
- The number of minutes of battery power remaining before the UPS driver will begin a graceful shutdown of the OS. A value of -1 indicates that no automatic shutdown will occur.
- cpqUpsLaunchCommand
- Application to launch for UPS support.
- cpqUpsAlarm
- This variable contains the UPS alarm text.
- cpqUpsMemberTable
- A table of entries that describes the family of rack-mounted servers that a single UPS supports.
- cpqUpsMemberEntry
- A table of entries that describes the family of rack-mounted servers that a single UPS supports.
- cpqUpsMemberIndex
- A unique index for this module description.
- cpqUpsMemberName
- The name or address of one of the individual servers that is served by the rack-mounted UPS. Set cpqUpsMemberName to 0 to delete this row.
- cpqUpsMemberCommunityStr
- The Community string for this individual server.
- cpqUpsAddMemberName
- To add a row to the cpqUpsMemberTable, this variable must be set, followed immediately by the set of the cpqUpsAddMemberCommunityStr. Sets must occur in this order, or else a new row will not be added to the table.
- cpqUpsAddMemberCommunityStr
- To add a row to the cpqUpsMemberTable, the cpqUpsAddMemberName must be set, followed immediately by a set of this variable. Sets must occur in this order, or else a new row will not be added to the cpqUpsMemberTable.