EES-POWER-MIB Download
Emerson Energy Systems (EES) Power MIB
IPHost Network Monitor offer an easy way of SNMP monitoring your Liebert Servers, Routers, Switches, Bridges,
Firewalls, Repeaters.
OID list for EES-POWER-MIB
- identManufacturer
- The name of the equipment manufacturer.
- identModel
- The manufacturers model designation of the power system.
- identControllerFirmwareVersion
- The firmware (software) version of the controller.
- identName
- The name of the power plant. This object should be set by the administrator.
- systemStatus
- Status of the complete plant (highest alarm). One of (1) unknown - status has not yet been defined (2) normal - there are no activated alarms (3) observation - OA, lowest level of 'abnormal' status (4) warning - A3 (5) minor - MA (6) major - CA, highest l ...
- systemVoltage
- System voltage, stored as mV, including positive or negative sign. The integer 2147483647 represents invalid value.
- systemCurrent
- System current, stored as mA, including positive or negative sign. The integer 2147483647 represents invalid value.
- systemUsedCapacity
- Used capacity, stored as % of the total capacity. The integer 2147483647 represents invalid value.
- psBatteryVoltage
- Battery voltage, stored as mV, including positive or negative sign. The integer 2147483647 represents invalid value.
- psBatteryCurrent
- Battery current, stored as mA, including positive or negative sign. The integer 2147483647 represents invalid value.
- psInputLineAVoltage
- The AC line A voltage, stored as mV. The integer 2147483647 represents invalid value.
- psInputLineBVoltage
- The AC line B voltage, stored as mV. The integer 2147483647 represents invalid value.
- psInputLineCVoltage
- The AC line C voltage, stored as mV. The integer 2147483647 represents invalid value.
- psTemperature1
- The first route temperature, stored as 0.001 Celsius degree. The integer 2147483647 represents invalid value.
- psTemperature2
- The second route temperature, stored as 0.001 Celsius degree. The integer 2147483647 represents invalid value..
- psStatusCommunication
- The status of communication with the Power System. interrupt(3) indicates some errors occurred between Power System and agent.
- psStatusBatteryMode
- The status of battery modes, FloatCharging(2), ShortTest(3), BoostChargingForTest(4), ManualTesting(5), PlanTesting(6), ACFailTesting(7), ACFail(8), ManualBoostCharging(9), AutoBoostCharging(10), CyclicBoostCharging(11), MasterBoostCharging(12), MasterBat ...
- psSMACNumber
- The number of SM AC module.
- psSMBATNumber
- The number of SM BAT module.
- psSMIONumber
- The number of SM IO module.
- alarmLastTrapNo
- The sequence number of last submitted alarm trap, also last row in alarmTrapTable.
- alarmTrapTable
- Table holding information about the submitted alarm traps.
- alarmTrapEntry
- An entry (conceptual row) in the alarmTrapTable.
- alarmTrapNo
- The unique sequence number of this alarm trap.
- alarmTime
- Date and time when event occured (local time), including timezone if supported by controller.
- alarmStatusChange
- The type of alarm change. One of (1) activated (2) deactivated
- alarmSeverity
- The severity of the alarm. One of (3) observation - OA, lowest level of alarm severity (4) warning - A3 (5) minor - MA (6) major - CA, highest level of alarm severity
- alarmDescription
- Free-text description of alarm.
- alarmType
- Alarm type, i.e. an integer specifying the type of alarm.