JUNIPER-POWER-SUPPLY-UNIT-MIB Download
The Juniper Supply Unit MIB definitions for enabling
power monitoring and management of a juniper device.
With the IPHost SNMP tool, you can monitor any SNMP objects of the
JUNIPER-POWER-SUPPLY-UNIT-MIB.
OID list for JUNIPER-POWER-SUPPLY-UNIT-MIB
- jnxPsuAvailableDeviceCount
- Gives the number of PSU units available online in the System.
- jnxPsuAvailableAveragePowerSupply
- Gives the total average power that the System can supply from the available online units in Watts.
- jnxPsuAvailableMaxPowerSupply
- Gives the total maximum power that the System can supply from the available online units in Watts.
- jnxPsuRedundancy
- PSU power redundancy configuration.
- jnxPsuChassisPowerReserved
- Power reserved for Chassis in Watts.
- jnxPsuChassisPowerAllocated
- Total power allocated for chassis and all the FPCs in Watts.
- jnxPsuRedundantPowerAvailable
- Power(in Watts) that is still available for allocation even while supporting redundancy with the present usage.
- jnxPsuTotalPowerAvailable
- Power(in Watts) which could be made available for further allocation without supporting any redundancy with the present usage.
- jnxPsuChassisPowerConsumed
- Total power consumed by the entire system rounded to the nearest integer. This is calculated using the PowerFactor, Current and Voltage values of each PSU that is online and connected to the System.
- jnxPsuTemperatureInflow
- Average inflow temperature calculated from all the available input sensors on the master RE.
- jnxPsuTemperatureOutflow
- Average outflow temperature calculated from all the available output sensors on the master RE.
- jnxPsuTemperatureInflowSamples
- The number of samples being taken while calculating jnxPsuTemperatureInflow.
- jnxPsuTemperatureOutflowSamples
- The number of samples being taken while calculating jnxPsuTemperatureOutflow.
- jnxPsuTable
- A list of power entries for each PSU component.
- jnxPsuEntry
- Defines an entry in jnxPsuTable.
- jnxPsuAvgPower
- for each component.
- jnxPsuMaxPower
- for each component.
- jnxPsuMode
- Mode for each PSU component.
- jnxPsuOutletCount
- present on this psu component, default is 0.
- jnxPsuEnvironmentTable
- A list of PSU Environment entries.
- jnxPsuEnvironmentEntry
- Defines an entry in jnxPsuEnvironmentTable.
- jnxPsuThermalValue
- the nearest integer.
- jnxPsuHumidityValue
- Humidity at each component in percentage.
- jnxPsuOutletTable
- capacity to supply power, and other details.
- jnxPsuOutletEntry
- A value contained within the OutletEntry
- jnxPsuOutletName
- each PSU Component.
- jnxPsuOutletDescription
- each PSU Component.
- jnxPsuOutletAvgPower
- Buffer that contains the average power used, in Watts for each component.
- jnxPsuOutletMaxPower
- Buffer that contains the maximum power available, in Watts for each component.
- jnxPsuOutletCurrent
- integer.
- jnxPsuOutletStatus
- This can also be used to set the outlet state
- jnxPsuOutletVoltage
- Output voltage in Volts rounded to the nearest integer.
- jnxPsuOutletPowerFactorValue
- Algorithm for calculation of Power Factor is below. For PowerOut values that fall in between 618.93W and 915.24W. let.s say 700W, the appropriate PF ranges from 0.910191 & 0.917994. Following linear equation could help deduce a fairly accurate input power ...
- jnxPsuOutletPowerConsumed
- Power Consumed by each outlet units in Watts.
- jnxPsuFpcPowerTable
- giving it's assigned priority and power being allocated. More information on FPCs can be found in JUNIPER-MIB.
- jnxPsuFpcPowerEntry
- A value contained within the FpcPowerEntry
- jnxPsuFpcPowerPriority
- Lower number means higher priority.
- jnxPsuFpcPowerAllocated
- The Power allocated to the FPC in Watts.