MG-SNMP-UPS-MIB

MG-SNMP-UPS-MIB Download

MIBs list

IPHost Network Monitor offer an easy way of SNMP monitoring your Eaton Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for MG-SNMP-UPS-MIB

upsmgIdentFamilyName
The UPS family name (e.g. `PULSAR', `COMET', `GALAXY', ...).
upsmgIdentModelName
The UPS model name (e.g. `PSX20', `SV9', ... ).
upsmgIdentRevisionLevel
The UPS revision level.
upsmgIdentFirmwareVersion
The UPS microprocessor firmware version number.
upsmgIdentUserID
The UPS user identification (set by administrator).
upsmgIdentInstallationDate
The UPS installation date in dd/mm/yy format.
upsmgIdentSerialNumber
The UPS manufacturing serial number.
upsmgManagersNum
The number of managers that could manage the UPS.
upsmgManagersTable
The table of managers.
upsmgManagersEntry
The description of a manager entry in the managers table.
mgmanagerIndex
A unique value for each manager. Its value ranges between 1 and the value of upsmgManagersNum.
mgmanagerDeviceNumber
This object is the number of the manager device in the DevicesTable of the Config group. This means that the manager is powered by the UPS. If not the default value is 0.
mgmanagerNMSType
The type of manager according to the NMS platform. We include in the manager class all systems which will be notified by the agent via receiving traps (e.g. basic to complex NMS software).
mgmanagerCommType
The level of communication protocol for that manager. Setting this object to value invalid(2) has the effect of invalidating the corresponding entry in the upsmgManagersTable. It is an implementation-specific matter as to wether the agent removes an inval ...
mgmanagerDescr
A textual string containing information about the manager. (manufacturer and version description).
mgmanagerAddress
The IP address of the manager station receiving traps. The value of this object is meaningful if and only if the value of the relevant mgmanagerCommType object is snmp type.
mgmanagerCommunity
The manager community string.
mgmanagerSeverityLevel
The severity level of traps to be received by this manager.
mgmanagerTrapAck
The manager Trap Acknowledgement status. Setting this object to mgnoack(2) or stdnomg(3) or cpqnoack(5) disables the trap acknowledgement from the related manager. The MG enterprise specific trap should then be sent only once by the agent to this manager ...
upsmgReceptaclesNum
The total number of receptacles controlled by the UPS.
upsmgReceptaclesTable
The table of receptacles that are controlled by the UPS.
upsmgReceptaclesEntry
The description of a receptacle in the table.
mgreceptacleIndex
A unique value for each receptacle. Its value ranges between 1 and the value of upsmgReceptaclesNum.
mgreceptacleLevel
The level of receptacle. Setting this object to value invalid(2) has the effect of invalidating the corresponding entry in the upsmgReceptaclesTable. It is an implementation-specific matter as to wether the agent removes an invalidated entry from the tabl ...
mgreceptacleType
A textual string for the receptacle type.
mgreceptacleIdent
A textual string identification for the user.
mgreceptacleState
The ON/OFF status of the receptacle.
mgreceptacleReceptacle
The receptacle number of the second level receptacle father. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
mgreceptaclePowerCons
The volt-ampere rating of the receptacle. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
mgreceptacleOverload
The overload status of the receptacle. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
mgreceptacleAutonomy
The receptacle autonomy. The value of this object is meaningful if and only if the value of the relevant mgreceptacleType object is related to a two-level receptacle class. Otherwise the default value is 0.
upsmgConfigBatteryInstalled
The battery installed status.
upsmgConfigNominalBatteryVoltage
The nominal battery voltage.
upsmgConfigNominalBatteryTime
The full load battery autonomy time.
upsmgConfigNominalRechargeTime
The recharge time to go from low battery cut off to full charge at full load.
upsmgConfigMinRechargeLevel
The minimum battery level required to supply power on the loads after low battery condition turn off and restart on main return.
upsmgConfigMaxRechargeTime
The maximum time delay of battery recharge before supply power to the loads.
upsmgConfigLowBatteryTime
To set remaining time value for low battery condition.
upsmgConfigLowBatteryLevel
To set battery level value for low battery condition.
upsmgConfigAutoRestart
The automatic restart enabling status.
upsmgConfigShutdownTimer
To set ups shutdown timer from on battery condition.
upsmgConfigSysShutDuration
To set ups shutdown delay (Sn delay).
upsmgConfigVARating
The UPS nominal VA rating.
upsmgConfigLowTransfer
The low voltage transfer point.
upsmgConfigHighTransfer
The high voltage transfer point.
upsmgConfigOutputNominalVoltage
The nominal output voltage.
upsmgConfigOutputNominalCurrent
The nominal output current.
upsmgConfigOutputNomFrequency
The nominal output frequency.
upsmgConfigByPassType
The UPS by pass switch type.
upsmgConfigAlarmAudible
To set audible alarm status.
upsmgConfigAlarmTimeDelay
To set audible alarm time delay.
upsmgConfigDevicesNum
The number of devices that are powered by the UPS.
upsmgConfigDevicesTable
The table of devices that are powered by the UPS.
upsmgConfigDevicesEntry
The description of a device entry in the devices table.
mgdeviceIndex
A unique value for each device. Its value ranges between 1 and the value of upsmgDevicesNum.
mgdeviceReceptacleNum
The receptacle number of the device plugged into the UPS. This value gives index entry in the ReceptaclesTable object of the Receptacle group. A value of 0 invalidates the entry in the DevicesTable.
mgdeviceIdent
A textual string for device user identification.
mgdeviceVaRating
The volt-ampere rating of the device plugged into the UPS.
mgdeviceSequenceOff
To set the device position in the remote shutdown sequence.
mgdeviceSequenceOn
To set the device position in the remote reboot sequence.
mgdeviceShutdownDuration
To set the duration from start of computer shut-down to complete.
mgdeviceBootUpDuration
To set the duration from start of computer boot-up to complete.
upsmgConfigReceptaclesTable
The table of receptacles.
upsmgConfigReceptaclesEntry
The description of a receptacle entry in the table.
mgreceptacleIndexb
A unique value for each receptacle. Its value ranges between 1 and the value of upsmgReceptaclesNum.
mgreceptacleStateTurnOn
Default return state at turn on.
mgreceptacleStateMainReturn
Default return state on main return.
mgreceptacleStateDischarge
Default return state on main return from battery discharge.
mgreceptacleShutoffLevel
Battery level for starting shutoff sequence.
mgreceptacleShutoffTimer
Time delay from on battery for starting shutoff sequence.
mgreceptacleRestartLevel
Battery level for starting restart sequence.
mgreceptacleRestartDelay
Time delay for starting restart sequence.
mgreceptacleShutdownDuration
Maximum Shutdown Duration for systems powered by this plug.
mgreceptacleBootUpDuration
Maximum Reboot Duration for systems powered by this plug.
upsmgConfigExtAlarmNum
The number of environ external alarm, value is between 8 and 32..
upsmgConfigExtAlarmTable
The table of environmental external alarms.
upsmgConfigExtAlarmEntry
The description of an external alarm in the table.
mgextAlarmIndex
A unique value for each external alarm. Its value ranges between 1 and the value of upsmgConfigExtAlarmNum.
mgextAlarmUID
A textual string for alarm state user identification.
upsmgConfigEmergencyTestFail
The emergency condition status on Battery test fail.
upsmgConfigEmergencyOnByPass
The emergency condition status on By Pass.
upsmgConfigEmergencyOverload
The emergency condition status on overload.
upsmgConfigControlDayTable
The table of daily on/off time.
upsmgConfigControlDayEntry
The description of a daily on/off time schedule in the table.
mgcontrolDayIndex
The day index. It is a number between 1 and 7, 1 for Sunday, 2 for Monday, ...
mgcontrolDayOn
To set daily power on time. Any value greater than 86400 is to disable the Day On.
mgcontrolDayOff
To set daily power off time. Any value greater than 86400 is to disable the Day Off.
upsmgConfigLowBooster
To set UPS booster low threshold.
upsmgConfigHighBooster
To set UPS booster high threshold.
upsmgConfigLowFader
To set UPS fader low threshold.
upsmgConfigHighFader
To set UPS fader high threshold.
upsmgConfigEnvironmentTable
The table containing the configuration of the environment sensor.
upsmgConfigEnvironmentEntry
The description of an entry in the table.
upsmgConfigSensorIndex
The sensor index, ranging from 1 to upsmgEnvironmentNum.
upsmgConfigSensorName
The sensor user-friendly name.
upsmgConfigTemperatureLow
The low temperature threshold in unit 0.1 Cel.
upsmgConfigTemperatureHigh
The high temperature threshold in unit 0.1 Cel.
upsmgConfigTemperatureHysteresis
The temperature hysteresys used for threshold test in unit 0.1 Cel.
upsmgConfigHumidityLow
The low humidity threshold in unit 1 %.
upsmgConfigHumidityHigh
The high humidity threshold in unit 1 %.
upsmgConfigHumidityHysteresis
The humidity hysteresys used for threshold test in unit 1 %.
upsmgConfigInput1Name
The Input #1 user-friendly name.
upsmgConfigInput1ClosedLabel
The Input #1 label for closed position.
upsmgConfigInput1OpenLabel
The Input #1 label for open position.
upsmgConfigInput2Name
The Input #2 user-friendly name.
upsmgConfigInput2ClosedLabel
The Input #2 label for closed position.
upsmgConfigInput2OpenLabel
The Input #2 label for open position.
upsmgBatteryRemainingTime
The time remaining actual charge vs actual load (dynamic).
upsmgBatteryLevel
The battery level as a percentage of charge.
upsmgBatteryRechargeTime
The actual operational battery recharge time to set point equal to upsmgConfigRechargeLevel. This value is computed from upsmgConfigRechargeLevel (level to reach), upsmgBatteryLevel (the actual reached level) and the UPS charge rate.
upsmgBatteryRechargeLevel
The actual value of the battery recharge level that will be reached during the time delay necessary to restart after power returns. This value is computed from upsmgConfigRechargeTime (the delay), upsmgBatteryLevel (the actual level) and the UPS charge ra ...
upsmgBatteryVoltage
The actual battery voltage.
upsmgBatteryCurrent
The actual battery current.
upsmgBatteryTemperature
The battery temperature.
upsmgBatteryFullRechargeTime
The battery full recharge time (from 0 to 100 percent) at current load.
upsmgBatteryFaultBattery
The battery fault status.
upsmgBatteryNoBattery
The UPS has no Battery status.
upsmgBatteryReplacement
The UPS Battery to be replaced status.
upsmgBatteryUnavailableBattery
The UPS Battery is unavailable status.
upsmgBatteryNotHighCharge
The UPS Battery quit high condition status.
upsmgBatteryLowBattery
The battery low status.
upsmgBatteryChargerFault
The UPS Battery is not charging status.
upsmgBatteryLowCondition
The UPS is at low condition status.
upsmgBatteryLowRecharge
The UPS Battery is not recharged status.
upsmgInputPhaseNum
The number of input phases.
upsmgInputPhaseTable
The table of input phases.
upsmgInputPhaseEntry
The description of an input phase.
mginputIndex
The input phase voltage index. It is a number between 1 and upsmgInputPhaseNum.
mginputVoltage
The input phase voltage.
mginputFrequency
The input phase frequency.
mginputMinimumVoltage
The input phase minimum voltage over the last minute.
mginputMaximumVoltage
The input phase maximum voltage over the last minute.
mginputCurrent
The input phase current.
upsmgInputBadStatus
The utility power bad voltage or bad frequency status.
upsmgInputLineFailCause
The utility power failure cause: no(1) is for no utility failure, outoftolvolt(2) is for voltage out of tolerance, outoftolfreq(3) is for frequency out of tolerance, utilityoff(4) is for no voltage at all.
upsmgOutputPhaseNum
The number of output phases.
upsmgOutputPhaseTable
The table of output phases.
upsmgOutputPhaseEntry
The description of an output phase.
mgoutputPhaseIndex
The output phase voltage index. It is a number between 1 and upsmgOutputPhaseNum.
mgoutputVoltage
The output phase voltage.
mgoutputFrequency
The output phase frequency.
mgoutputLoadPerPhase
The output load per phase.
mgoutputCurrent
The output phase current.
upsmgOutputOnBattery
The UPS on battery / on main status.
upsmgOutputOnByPass
The UPS on bypass status.
upsmgOutputUnavailableByPass
The by pass unavailable status.
upsmgOutputNoByPass
The UPS bypass installed status.
upsmgOutputUtilityOff
The UPS utility off status.
upsmgOutputOnBoost
The UPS on booster status.
upsmgOutputInverterOff
The UPS Inverter on / off status.
upsmgOutputOverLoad
The output over load status.
upsmgOutputOverTemp
The ups over temperature status.
upsmgOutputOnBuck
The UPS on fader status.
upsmgEnvironAmbientTemp
The ambient temperature.
upsmgEnvironAmbientHumidity
The ambient humidity.
upsmgEnvironExtAlarmTable
The table of external alarms.
upsmgEnvironExtAlarmEntry
The description of an external alarm.
mgalarmNum
The external alarm number. A number between 1 and upsmgConfigExtAlarmNum.
mgalarmState
The external alarm state (active or inactive).
upsmgEnvironSensorNum
The sensor unit number (0 to 4).
upsmgEnvironSensorTable
The table of sensor units.
upsmgEnvironSensorEntry
The description of a sensor unit.
mgsensorNum
The unit number. A number between 1 and 4.
mgsensorTemp
The measured temperature of the unit.
mgsensorHumidity
The measured humidity of the unit.
upsmgEnvironmentNum
Number of Environment sensor connected.
upsmgEnvironmentSensorTable
The table containing the measurements and alarms made by Environment sensor units.
upsmgEnvironmentSensorEntry
The description of an entry in the measurement table.
upsmgEnvironmentIndex
The sensor index, ranging from 1 to upsmgEnvironmentNum.
upsmgEnvironmentComFailure
The sensor communication failure : yes(1), no(2).
upsmgEnvironmentTemperature
The temperature measurement in unit 0.1 Cel.
upsmgEnvironmentTemperatureLow
Temperature is below low theshold : yes(1), no(2).
upsmgEnvironmentTemperatureHigh
Temperature is above high threshold : yes(1), no(2).
upsmgEnvironmentHumidity
The humidity measurement in unit 0.1 %.
upsmgEnvironmentHumidityLow
Humidity is below low threshold : yes(1), no(2).
upsmgEnvironmentHumidityHigh
Humidity is above high threshold : yes(1), no(2).
upsmgEnvironmentInput1State
State of Input#1 : closed(1), open(2).
upsmgEnvironmentInput2State
State of Input#2 : closed(1), open(2).
upsmgControlReceptaclesTable
The table of receptacles.
upsmgControlReceptaclesEntry
The description of a receptacle entry in the table.
mgreceptacleIndexc
A unique value for each receptacle. Its value ranges between 1 and the value of upsmgReceptaclesNum.
mgreceptacleOnDelay
Turn on UPS receptacle w/delay=?.
mgreceptacleOnCtrl
The receptacle control on action.
mgreceptacleOnStatus
The receptacle control on status.
mgreceptacleOffDelay
Turn off UPS receptacle w/delay=?.
mgreceptacleOffCtrl
The receptacle control off action.
mgreceptacleOffStatus
The receptacle control off status.
mgreceptacleToggleDelay
Turn off then on UPS receptacle w/delay=?.
mgreceptacleToggleCtrl
The receptacle control toggle action.
mgreceptacleToggleStatus
The receptacle control toggle status.
mgreceptacleToggleDuration
Turn off then on UPS receptacle w/duration=?.
upsmgControlDayOff
The schedule off control object. Default value is none(8). Value 1 means to start scheduled off on Sunday, value 2 to start scheduled off on Monday, and so on.
upsmgControlDayOn
The schedule on control object. Default value is none(8). Value 1 means to start scheduled on on Sunday, value 2 to start scheduled on on Monday, and so on. This object is meaningfull only for those agent that do not include internal clock. In such a case ...
upsmgTestBatterySchedule
The automatic battery test schedule.
upsmgTestDiagnostics
To run self test diagnostics.
upsmgTestDiagResult
The automatic test diagnostic result.
upsmgTestBatteryCalibration
To run battery test calibration.
upsmgTestLastCalibration
The last battery calibration test date.
upsmgTestIndicators
To run UPS indicators test.
upsmgTestCommandLine
To send ASCII command line to UPS.
upsmgTestCommandReady
To advise UPS that command line has been prepared.
upsmgTestResponseLine
To get ASCII protocol response from UPS.
upsmgTestResponseReady
To advise agent that response line has been received.
upsmgTestBatteryResult
The test battery result: msuccess(1) is for manual battery test success, ssuccess(3) is for scheduled battery test success, mfailed(2) is for manual battery test failed, sfailed(4) is for scheduled battery test failed.
upsmgAgentIpaddress
The ip address that NMS can identify the managed device
upsmgAgentSubnetMask
Internet address subnet mask
upsmgAgentDefGateway
The default gateway that allow device managed through routers
upsmgAgentBaudRate
the serial port communication speed. only 2400, 4800, and 9600 allowed
upsmgAgentPollRate
The frequency that proxy agent polls the connected UPS in ASCII protocol. (unit : second)
upsmgAgentType
The type of agent.
upsmgAgentTrapAlarmDelay
The interval for the Trap packet retransmission, while the TRAP Acknowledge is implemented and the ack is received within the interval.
upsmgAgentTrapAlarmRetry
The retry count for retransmitting Trap packet while the TRAP acknowledge is implemented.
upsmgAgentReset
The variable initiates reset operation in agent software, ie. warm start. write reset(1) to any one of UPS MIB array, will result in the same reset operation.
upsmgAgentFactReset
The variable initiates reset operation in agent software, ie. warm start, and load default data (Factory setting) to EEPROM and to runtime parameters associated with the UPS.
upsmgAgentMibVersion
The version of the MIB implemented in agent.
upsmgAgentFirmwareVersion
The agent firmware version.
upsmgAgentCommUPS
The status of communication between agent and ups. Even value means no communication, and odd value means a certain level of communication with devices daisy-chained on the serial port. The value is the following: 1000*NSE + 100*NSW + 10*UPSW + UPST with ...
upsmgAgentTrapAck
The last Trap number that has been received by UM-View.
upsmgAgentAutoLearning
The enabled/disabled configuration of the Auto Learning process of the agent, default value is yes(1) e.g. enabled.
upsmgAgentBootP
The enabled/disabled configuration of the BootP process, default value is yes(1) e.g. enabled.
upsmgAgentTFTP
The enabled/disabled configuration of the TFTP process, default value is no(2) e.g. disabled.
upsmgAgentTrapSignature
The signature of the trap acknowledged by a manager.
upsmgRemoteOnBattery
An object to inform an ups-less agent that the remote UPS is on autonomy. This object could be set by a management application.
upsmgRemoteIpAddress
An object to give the IP address of the agent managing the remote UPS. This object could be read by managers to perform management of receptacle dependencies between two different agents.