XYLAN-DS1-MIB Download
With the IPHost SNMP tool, you can monitor any SNMP objects of the
XYLAN-DS1-MIB
. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables,
their current values and descriptions taken from the
XYLAN-DS1-MIB
.
OID list for XYLAN-DS1-MIB
- dsx1PortConfigTable
- A table of Dsx1 physical layer status and parameter information.
- dsx1PortConfigEntry
- An entry in the table, containing information about the physical layer of a Dsx1 interface.
- dsx1PortConfigSlotIndex
- A unique value which identifies this HSM board slot.
- dsx1PortConfigPortIndex
- A unique value which identifies this port.
- dsx1PortConfigIfType
- The type of interface.
- dsx1PortFdlRole
- Indicates Facility Data Link port role of this port. If the port role is network and fdlMode is set to AT&T 54016, then this port periodically sends AT&T performance requests to CI.
- dsx1PortNfasAlign
- This object indicates if framing criterion is based on bit 2 of Time Slot 0 NOT-FAS. This object only applies to E1.
- dsx1PortConfigYelAlarmDetectEnable
- This object indicates whether Yellow Alarm should be detected.
- dsx1PortStatsTable
- A table of Dsx1 physical port statistics.
- dsx1PortStatsEntry
- An entry in the table, containing information about the physical port statistics of a Dsx1 interface.
- dsx1PortStatsSlotIndex
- A unique value which identifies this HSM board slot.
- dsx1PortStatsPortIndex
- A unique value which identifies this port.
- dsx1PortStatsLossOfSignal
- Total number of Loss of Signals that have been detected on this port.
- dsx1PortStatsOutOfFrame
- Total number of Out of Frames that have been detected on this port.
- dsx1PortStatsRedAlarmEvent
- Total number of Red Alarm events that have been detected on this port.
- dsx1PortStatsYellowAlarmEvent
- Total number of Yellow Alarm events that have been detected on this port. This object applies to T1 port only.
- dsx1PortStatsSquelchAlarmEvent
- Total number of Squelch Alarm events that have been detected on this port.
- dsx1PortStatsBipolarVioEvent
- Total number of Bipolar Violation events that have been detected on this port.
- dsx1PortStatsAISEvent
- Total number of AIS events that have been detected on this port.
- dsx1PortStatsCrcErrorEvent
- Total number of ESF CRC-6 Error events for T1 or CRC-4 Error Events for E1 that have been detected on this port.
- dsx1PortStatsOutOfSubMultiFrame
- Total number of out of sub-multiframe events that have been detected on this port. This object only applies to E1 port.
- dsx1PortStatsOutOfTs16MultiFrame
- Total number of out of TS 16 multiframe events that have been detected on this port. This object only applies to E1 port.
- dsx1PortStatsRemFrameAlarm
- Total number of Remote Frame Alarm events that have been detected on this port. This object only applies to E1 port.
- dsx1PortStatsRemMultiFrameAlarm
- Total number of Remote MultifFame Alarm events that have been detected on this port. This object only applies to E1 port.
- dsx1PortStatsFarEndBlkError
- Total number of Far End Block Error events that have been detected on this port. This object only applies to E1 port.
- dsx1PortStatsFramingBitError
- Total number of Framing Bit Error events that have been detected on this port.
You can start network devices monitoring using free 30-day trial version of IPHost Network Monitor right now.
Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access.