ZYXEL-VDSLLINE-MIB Download
With the IPHost SNMP tool, you can monitor any SNMP objects of the
ZYXEL-VDSLLINE-MIB
. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables,
their current values and descriptions taken from the
ZYXEL-VDSLLINE-MIB
.
OID list for ZYXEL-VDSLLINE-MIB
- accessSwitchVdslLineTable
- This table includes common attributes describing both ends of the line.
- accessSwitchVdslLineEntry
- An entry in the accessSwitchVdslLineTable.
- accessSwitchVdslLineCoding
- Specifies the VDSL coding type used on this line.
- accessSwitchVdslLineDiscCount
- Count of the number of disconnection failures since agent reset.
- accessSwitchVdslLineConfProfile
- The value of this object identifies the row in the VDSL Line Configuration Profile Table, (accessSwitchVdslLineConfProfileTable), which applies for this VDSL line.
- accessSwitchVdslVtuoPhysTable
- This table provides one row for each VTU-O. Each row contains the physical layer parameters for that VTU-O.
- accessSwitchVdslVtuoPhysEntry
- An entry in the accessSwitchVdslVtuoPhysTable.
- accessSwitchVdslVtuoCurrSnrMgn
- Noise Margin as seen by this VTU with respect to its received signal in 0.01dB.
- accessSwitchVdslVtuoCurrMse
- Minimum Square Error as seen by this VTU with respect to its received signal in 0.01dB.
- accessSwitchVdslVtuoCurrPsd
- Power Spectral Density as seen by this VTU with respect to its received signal in 0.01dBm/Hz.
- accessSwitchVdslVtuoCurrRsErr
- Reed-Solomon error counted by this VTU with respect to its received signal.
- accessSwitchVdslVtuoCurrAtn
- Measured difference in the total power transmitted by the peer VTU and the total power received by this VTU.
- accessSwitchVdslVtuoCurrOutputPwr
- Measured total output power in 0.01dBm transmitted by this VTU.
- accessSwitchVdslVtuoCurrRate
- Actual transmission rate in bits-per-second on this line.
- accessSwitchVdslVtuoCurrAttainableRate
- Indicates the maximum mandatoryly attainable data rate in bits-per-second by the VTU. This value will be equal or greater than the mandatory line rate.
- accessSwitchVdslVtuoCurrStatus
- Indicates mandatory state of the VTU-O line. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There no defects on the line 1 lossOfFraming VTU-O failure due to not receiving valid frame. 2 ...
- accessSwitchVdslVturPhysTable
- This table provides one row for each VTU-R. Each row contains the physical layer parameters for that VTU-R.
- accessSwitchVdslVturPhysEntry
- An entry in the accessSwitchVdslVturPhysTable.
- accessSwitchVdslVturCurrSnrMgn
- Noise Margin as seen by this VTU with respect to its received signal in 0.01dB.
- accessSwitchVdslVturCurrMse
- Minimum Square Error as seen by this VTU with respect to its received signal in 0.01dB.
- accessSwitchVdslVturCurrPsd
- Power Spectral Density as seen by this VTU with respect to its received signal in 0.01dBm/Hz.
- accessSwitchVdslVturCurrRsErr
- Reed-Solomon error counted by this VTU with respect to its received signal.
- accessSwitchVdslVturCurrAtn
- Measured difference in the total power transmitted by the peer VTU and the total power received by this VTU.
- accessSwitchVdslVturCurrOutputPwr
- Measured total output power in 0.01dBm transmitted by this VTU.
- accessSwitchVdslVturCurrRate
- Actual transmission rate in bits-per-second on this line.
- accessSwitchVdslVturCurrAttainableRate
- Indicates the maximum mandatoryly attainable data rate in bits-per-second by the VTU. This value will be equal or greater than the mandatory line rate.
- accessSwitchVdslVturCurrStatus
- Indicates mandatory state of the VTU-R line. This is a bit-map of possible conditions. The various bit positions are: 0 noDefect There no defects on the line 1 lossOfFraming VTU-R failure due to not receiving valid frame. 2 ...
- accessSwitchVdslVtuoInventoryTable
- This table provides one row for each VTU-O. Each row contains the inventory parameters for that VTU-O.
- accessSwitchVdslVtuoInventoryEntry
- An entry in the accessSwitchVdslVtuoInventoryTable.
- accessSwitchVdslVtuoInvSerialNumber
- The vendor specific string that identifies the vendor equipment.
- accessSwitchVdslVtuoInvVendorID
- The vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters.
- accessSwitchVdslVtuoInvVersionNumber
- The vendor specific version number sent by this VTU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[10] and expressed as readable characters.
- accessSwitchVdslVturInventoryTable
- This table provides one row for each VTU-R. Each row contains the inventory parameters for that VTU-R.
- accessSwitchVdslVturInventoryEntry
- An entry in the accessSwitchVdslVturInventoryTable.
- accessSwitchVdslVturInvSerialNumber
- The vendor specific string that identifies the vendor equipment.
- accessSwitchVdslVturInvVendorID
- The vendor ID code is a copy of the binary vendor identification field defined by the PHY[10] and expressed as readable characters.
- accessSwitchVdslVturInvVersionNumber
- The vendor specific version number sent by this VTU as part of the initialization messages. It is a copy of the binary version number field defined by the PHY[10] and expressed as readable characters.
- accessSwitchVdslVtuoPerfDataTable
- This table provides one row for each VTU-O.
- accessSwitchVdslVtuoPerfDataEntry
- An entry in accessSwitchVdslVtuoPerfDataTable.
- accessSwitchVdslVtuoPerfLofs
- Count of the number of Loss of Framing failures since agent reset.
- accessSwitchVdslVtuoPerfLoss
- Count of the number of Loss of Signal failures since agent reset.
- accessSwitchVdslVtuoPerfLols
- Count of the number of Loss of Link failures since agent reset.
- accessSwitchVdslVtuoPerfLprs
- Count of the number of Loss of Power failures since agent reset.
- accessSwitchVdslVtuoPerfESs
- Count of the number of Errored Seconds since agent reset. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVtuoPerfInits
- Count of the line initialization attempts since agent reset. Includes both successful and failed attempts.
- accessSwitchVdslVtuoPerfValidIntervals
- The number of previous 15-minute intervals in the interval table for which data was collected. Given that
is the maximum # of intervals supported. The value will be unless the measurement was (re-)started within the last ( *15) minutes, in whic ... - accessSwitchVdslVtuoPerfInvalidIntervals
- The number of intervals in the range from 0 to the value of accessSwitchVdslVtuoPerfValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situa ...
- accessSwitchVdslVtuoPerfCurr15MinTimeElapsed
- Total elapsed seconds in this interval.
- accessSwitchVdslVtuoPerfCurr15MinLofs
- Count of seconds in the mandatory 15 minute interval when there was Loss of Framing.
- accessSwitchVdslVtuoPerfCurr15MinLoss
- Count of seconds in the mandatory 15 minute interval when there was Loss of Signal.
- accessSwitchVdslVtuoPerfCurr15MinLols
- Count of seconds in the mandatory 15 minute interval when there was Loss of Link.
- accessSwitchVdslVtuoPerfCurr15MinLprs
- Count of seconds in the mandatory 15 minute interval when there was Loss of Power.
- accessSwitchVdslVtuoPerfCurr15MinESs
- Count of Errored Seconds in the mandatory 15 minute interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVtuoPerfCurr15MinInits
- Count of the line initialization attempts in the mandatory 15 minute interval. Includes both successful and failed attempts.
- accessSwitchVdslVtuoPerfCurr1DayTimeElapsed
- Number of seconds that have elapsed since the beginning of the mandatory 1-day interval.
- accessSwitchVdslVtuoPerfCurr1DayLofs
- Count of the number of seconds when there was Loss of Framing during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
- accessSwitchVdslVtuoPerfCurr1DayLoss
- Count of the number of seconds when there was Loss of Signal during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
- accessSwitchVdslVtuoPerfCurr1DayLols
- Count of the number of seconds when there was Loss of Link during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
- accessSwitchVdslVtuoPerfCurr1DayLprs
- Count of the number of seconds when there was Loss of Power during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed.
- accessSwitchVdslVtuoPerfCurr1DayESs
- Count of Errored Seconds during the mandatory day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVtuoPerfCurr1DayInits
- Count of the line initialization attempts in the day as measured by accessSwitchVdslVtuoPerfCurr1DayTimeElapsed. Includes both successful and failed attempts.
- accessSwitchVdslVtuoPerfPrev1DayMoniSecs
- The amount of time in the previous 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the interval duration except in a situation where performance monitoring data could not be collected fo ...
- accessSwitchVdslVtuoPerfPrev1DayLofs
- Count of seconds in the interval when there was Loss of Framing within the most recent previous 1-day period.
- accessSwitchVdslVtuoPerfPrev1DayLoss
- Count of seconds in the interval when there was Loss of Signal within the most recent previous 1-day period.
- accessSwitchVdslVtuoPerfPrev1DayLols
- Count of seconds in the interval when there was Loss of Link within the most recent previous 1-day period.
- accessSwitchVdslVtuoPerfPrev1DayLprs
- Count of seconds in the interval when there was Loss of Power within the most recent previous 1-day period.
- accessSwitchVdslVtuoPerfPrev1DayESs
- Count of Errored Seconds within the most recent previous 1-day period. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVtuoPerfPrev1DayInits
- Count of the line initialization attempts in the most recent previous 1-day period. Includes both successful and failed attempts.
- accessSwitchVdslVturPerfDataTable
- This table provides one row for each VTU-R.
- accessSwitchVdslVturPerfDataEntry
- An entry in accessSwitchVdslVturPerfDataTable.
- accessSwitchVdslVturPerfLofs
- Count of the number of Loss of Framing failures since agent reset.
- accessSwitchVdslVturPerfLoss
- Count of the number of Loss of Signal failures since agent reset.
- accessSwitchVdslVturPerfLprs
- Count of the number of Loss of Power failures since agent reset.
- accessSwitchVdslVturPerfESs
- Count of the number of Errored Seconds since agent reset. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVturPerfValidIntervals
- The number of previous 15-minute intervals in the interval table for which data was collected. Given that
is the maximum # of intervals supported. The value will be unless the measurement was (re-)started within the last ( *15) minutes, in whic ... - accessSwitchVdslVturPerfInvalidIntervals
- The number of intervals in the range from 0 to the value of accessSwitchVdslVturPerfValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situa ...
- accessSwitchVdslVturPerfCurr15MinTimeElapsed
- Total elapsed seconds in this interval.
- accessSwitchVdslVturPerfCurr15MinLofs
- Count of seconds in the mandatory 15 minute interval when there was Loss of Framing.
- accessSwitchVdslVturPerfCurr15MinLoss
- Count of seconds in the mandatory 15 minute interval when there was Loss of Signal.
- accessSwitchVdslVturPerfCurr15MinLprs
- Count of seconds in the mandatory 15 minute interval when there was Loss of Power.
- accessSwitchVdslVturPerfCurr15MinESs
- Count of Errored Seconds in the mandatory 15 minute interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVturPerfCurr1DayTimeElapsed
- Number of seconds that have elapsed since the beginning of the mandatory 1-day interval.
- accessSwitchVdslVturPerfCurr1DayLofs
- Count of the number of seconds when there was Loss of Framing during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed.
- accessSwitchVdslVturPerfCurr1DayLoss
- Count of the number of seconds when there was Loss of Signal during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed.
- accessSwitchVdslVturPerfCurr1DayLprs
- Count of the number of seconds when there was Loss of Power during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed.
- accessSwitchVdslVturPerfCurr1DayESs
- Count of Errored Seconds during the mandatory day as measured by accessSwitchVdslVturPerfCurr1DayTimeElapsed. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVturPerfPrev1DayMoniSecs
- The amount of time in the previous 1-day interval over which the performance monitoring information is actually counted. This value will be the same as the interval duration except in a situation where performance monitoring data could not be collected fo ...
- accessSwitchVdslVturPerfPrev1DayLofs
- Count of seconds in the interval when there was Loss of Framing within the most recent previous 1-day period.
- accessSwitchVdslVturPerfPrev1DayLoss
- Count of seconds in the interval when there was Loss of Signal within the most recent previous 1-day period.
- accessSwitchVdslVturPerfPrev1DayLprs
- Count of seconds in the interval when there was Loss of Power within the most recent previous 1-day period.
- accessSwitchVdslVturPerfPrev1DayESs
- Count of Errored Seconds within the most recent previous 1-day period. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVtuoIntervalTable
- This table provides one row for each VTU-O performance data collection interval.
- accessSwitchVdslVtuoIntervalEntry
- An entry in the accessSwitchVdslVtuoIntervalTable.
- accessSwitchVdslVtuoIntervalNumber
- Performance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
- accessSwitchVdslVtuoIntervalLofs
- Count of seconds in the interval when there was Loss of Framing.
- accessSwitchVdslVtuoIntervalLoss
- Count of seconds in the interval when there was Loss of Signal.
- accessSwitchVdslVtuoIntervalLols
- Count of seconds in the interval when there was Loss of Link.
- accessSwitchVdslVtuoIntervalLprs
- Count of seconds in the interval when there was Loss of Power.
- accessSwitchVdslVtuoIntervalESs
- Count of Errored Seconds in the interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVtuoIntervalInits
- Count of the line initialization attempts during the interval. Includes both successful and failed attempts.
- accessSwitchVdslVtuoIntervalValidData
- This variable indicates if the data for this interval is valid.
- accessSwitchVdslVturIntervalTable
- This table provides one row for each VTU-R performance data collection interval.
- accessSwitchVdslVturIntervalEntry
- An entry in the accessSwitchVdslVturIntervalTable.
- accessSwitchVdslVturIntervalNumber
- Performance Data Interval number 1 is the the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are optional.
- accessSwitchVdslVturIntervalLofs
- Count of seconds in the interval when there was Loss of Framing.
- accessSwitchVdslVturIntervalLoss
- Count of seconds in the interval when there was Loss of Signal.
- accessSwitchVdslVturIntervalLprs
- Count of seconds in the interval when there was Loss of Power.
- accessSwitchVdslVturIntervalESs
- Count of Errored Seconds in the interval. The errored second parameter is a count of one-second intervals containing one or more crc anomalies, or one or more los or sef defects.
- accessSwitchVdslVturIntervalValidData
- This variable indicates if the data for this interval is valid.
- accessSwitchVdslLineConfProfileTable
- This table contains information on the VDSL line configuration. One entry in this table reflects a profile which can be used to configure the VDSL line.
- accessSwitchVdslLineConfProfileEntry
- Each entry consists of a list of parameters that represents the configuration of an VDSL modem. When `dynamic' profiles are implemented, a default profile will always exist. This profile's name will be set to `DEFVAL' and its parameters will be set to ve ...
- accessSwitchVdslLineConfProfileName
- This object is used by the line configuration table in order to identify a row of this table. When `dynamic' profiles are implemented, the profile name is user specified. Also, the system will always provide a default profile whose name is `DEFVAL'. When ...
- accessSwitchVdslLineConfMode
- Specifies the VDSL mode type used on this line.
- accessSwitchVdslVtuoConfRate
- Transmission rate in bits-per-second specified by this VTU.
- accessSwitchVdslVtuoConfTargetSnrMgn
- Configured Target Signal/Noise Margin in 0.01dB. This is the Noise Margin the modem must achieve with a BER of 10-7 or better to successfully complete initialization.
- accessSwitchVdslVtuoConfMaxSnrMgn
- Configured Maximum acceptable Signal/Noise Margin in 0.01dB. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize its operation.
- accessSwitchVdslVtuoConfMinSnrMgn
- Configured Minimum acceptable Signal/Noise Margin in 0.01dB. If the noise margin falls below this level, the modem should attempt to increase its power output. If that is not possible the modem will attempt to re-initialize or shut down.
- accessSwitchVdslVturConfRate
- Transmission rate in bits-per-second specified by this VTU.
- accessSwitchVdslVturConfTargetSnrMgn
- Configured Target Signal/Noise Margin in 0.01dB. This is the Noise Margin the modem must achieve with a BER of 10-7 or better to successfully complete initialization.
- accessSwitchVdslVturConfMaxSnrMgn
- Configured Maximum acceptable Signal/Noise Margin in 0.01dB. If the Noise Margin is above this the modem should attempt to reduce its power output to optimize its operation.
- accessSwitchVdslVturConfMinSnrMgn
- Configured Minimum acceptable Signal/Noise Margin in 0.01dB. If the noise margin falls below this level, the modem should attempt to increase its power output. If that is not possible the modem will attempt to re-initialize or shut down.
- accessSwitchVdslLineConfProfileRowStatus
- This object is used to create a new row or modify or delete an existing row in this table. A profile activated by setting this object to `active'. When `active' is set, the system will validate the profile. Before a profile can be deleted or taken out of ...
- vesMaxNumOfProfiles
- The maximum number of VDSL profiles which the system supports.
- accessSwitchVdslVtuoQamTable
- This table provides one row for each VTU-O if QAM is used. Each row contains the modulation parameters for that VTU-O.
- accessSwitchVdslVtuoQamEntry
- An entry in the accessSwitchVdslVtuoQamTable.
- accessSwitchVdslVtuoQamConstellation
- Modulation method used by this VTU.
- accessSwitchVdslVtuoQamInterpolation
- Modulation speed used by this VTU.
- accessSwitchVdslVtuoQamFc
- Carrier frequency in Hz used by this ATU.
- accessSwitchVdslVturQamTable
- This table provides one row for each VTU-R if QAM is used. Each row contains the modulation parameters for that VTU-R.
- accessSwitchVdslVturQamEntry
- An entry in the accessSwitchVdslVturQamTable.
- accessSwitchVdslVturQamConstellation
- Modulation method used by this VTU.
- accessSwitchVdslVturQamInterpolation
- Modulation speed used by this VTU.
- accessSwitchVdslVturQamFc
- Carrier frequency in Hz used by this ATU.
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.
Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access.
The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.