cpqHeTemperatureCondition - Compaq Server Health Temperature Condition - CPQHLTH

MIBs list

cpqHeTemperatureCondition

Compaq Server Health Temperature Condition
1.3.6.1.4.1.232.6.2.6.8.1.6

The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.

Back to CPQHLTH MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqHeTemperatureCondition with IPHost tools

MIBs list