ctron-ethernet-parameters - ctAutoNegAdvertisedTechnologyAbility

MIBs list

ctAutoNegAdvertisedTechnologyAbility

Cabletron Auto Negotiation Advertised Technology Ability
1.3.6.1.4.1.52.4.1.2.4.2.1.1.1.5

Indicates the advertised ability of the local hardware, but only becomes active on ports that have auto-negotiation enabled. The value is a sum. This sum initially takes the value zero. Then, for each technology, T, that the port is advertising, 2 raised to (T - 1) is added to the sum. For example, a port that advertises 1000BASE-TFD (T = 18) and 1000BASE-T (T = 17) would return a value of 196608 ((2 ^ (18 - 1)) + (2 ^ (17 - 1))). Values for T are limited to technologies supported by the hardware as specified by ctAutoNegLocalTechnologyAbility. For ports supporting Auto-Negotiation, values should be calculated as follows: T Technology Description -- ----------- ------------------------------------------------ 1 global Reserved for future use. 2 other None of the following. 3 unknown Initializing, true state or type not yet known 4 10BASE-T 10BASE-T Half Duplex 5 10BASE-TFD 10BASE-T Full Duplex 6 100BASE-T4 100BASE-T4 Half Duplex 7 100BASE-TX 100BASE-TX Half Duplex 8 100BASE-TXFD 100BASE-TX Full Duplex 9 FDX PAUSE Full Duplex Flow Control 10 FDX APAUSE Full Duplex Asymmetric Flow Control 11 FDX SPAUSE Full Duplex Symmetric Flow Control 12 FDX BPAUSE Full Duplex Asymmetric and Symmetric Flow Control 13 100BASE-T2 100BASE-T2 Half Duplex 14 100BASE-T2FD 100BASE-T2 Full Duplex 15 1000BASE-X 1000BASE-X Half Duplex 16 1000BASE-XFD 1000BASE-X Full Duplex 17 1000BASE-T 1000BASE-T Half Duplex 18 1000BASE-TFD 1000BASE-T Full Duplex 19 Rem Fault1 Remote Fault Bit 1 20 Rem Fault2 Remote Fault Bit 2 21 ISO Ethernet IEEE Std 802.9 ISLAN-16T A successful set operation will result in immediate link re-negotiation if Auto-Negotiation is enabled on this port, as specified by ctAutoNegAdminStatus. A set of this object to a value containing bits that are not supported by the hardware will be successful, but, the port will only advertise values which are the logical AND of the set value and ctAutoNegLocalTechnologyAbility. Note: this re-negotiation will in every case cause temporary link loss during the link re-negotiation. If set to a value that is incompatible with ctAutoNegLocalTechnologyAbility, link negotiation will not be successful and will cause permanent link loss.

Back to ctron-ethernet-parameters MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

MIBs list