rfc1759 Download
With the IPHost SNMP tool, you can monitor any SNMP objects of the
rfc1759-printer-mib
. You can select a variable to monitor using the built-in IPHost MIB browser that provides you with all variables,
their current values and descriptions taken from the
rfc1759-printer-mib
.
OID list for rfc1759
- prtGeneralTable
- A table of general information per printer. Objects in this table are defined in various places in the MIB, nearby the groups to which they apply. They are all defined here to minimize the number of tables that would otherwise need to exist.
- prtGeneralEntry
- An entry exists in this table for each device entry in the hostmib device table who's type is `printer'
- prtGeneralConfigChanges
- Counts configuration changes that change the capabilities of a printer, such as the addition/deletion of input/output bins, the addition/deletion of interpreters, or changes in media size. Such changes will often affect the capability of the printer to s ...
- prtGeneralCurrentLocalization
- The value of the prtLocalizationIndex corresponding to the current language, country, and character set to be used for localized string values that are identified as being dependent on the value of this object. Note that this object does not apply to loc ...
- prtGeneralReset
- Setting this value to `powerCycleReset', `resetToNVRAM', or `resetToFactoryDefaults' will result in the resetting of the printer. When read, this object will always have the value `notResetting(3)', and a SET of the value `notResetting' shall have no eff ...
- prtCoverTable
- A table of the covers and interlocks of the printer.
- prtCoverEntry
- Information about a cover or interlock. Entries may exist in the table for each device index whose device type is `printer'.
- prtCoverIndex
- A unique value used by the printer to identify this Cover sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new cover sub-units to the printer), values are expected to remain stable across succe ...
- prtCoverDescription
- The manufacturer provided cover sub-mechanism name in the localization specified by prtGeneralCurrentLocalization.
- prtCoverStatus
- The status of this cover sub-unit.
- prtLocalizationTable
- The available localizations in this printer.
- prtLocalizationEntry
- A description of a localization. Entries may exist in the table for each device index who's device type is `printer'.
- prtLocalizationIndex
- A unique value used by the printer to identify this localization entry. Although these values may change due to a major reconfiguration of the device (e.g., the addition of new Cover sub-units to the printer), values are expected to remain stable across ...
- prtLocalizationLanguage
- A two character language code from ISO 639. Examples EN, GB, CA, FR, DE.
- prtLocalizationCountry
- A two character country code from ISO 3166, a blank string (two space characters) shall indicate that the country is not defined. Examples: US, FR, DE, ...
- prtLocalizationCharacterSet
- The coded character set used for this localization.
- prtStorageRefTable
- prtStorageRefEntry
- This table will have an entry for each entry in the host MIB storage table that represents storage associated with a printer managed by this agent.
- prtStorageRefSeqNumber
- This value will be unique amongst all entries with a common value of hrStorageIndex. This object allows a storage entry to point to the multiple printer devices with which it is associated.
- prtStorageRefIndex
- The value of the hrDeviceIndex of the printer device that this storageEntry is associated with.
- prtDeviceRefTable
- prtDeviceRefEntry
- This table will have an entry for each entry in the host MIB device table that represents a device associated with a printer managed by this agent.
- prtDeviceRefSeqNumber
- This value will be unique amongst all entries with a common value of hrDeviceIndex. This object allows a device entry to point to the multiple printer devices with which it is associated.
- prtDeviceRefIndex
- The value of the hrDeviceIndex of the printer device that this deviceEntry is associated with.
- prtGeneralCurrentOperator
- The name of the current human operator responsible for operating this printer. It is suggested that this string include information that would enable other humans to reach the operator, such as a phone number.
- prtGeneralServicePerson
- The name of the last human responsible for servicing this printer. It is suggested that this string include information that would enable other humans to reach the service person, such as a phone number.
- prtInputDefaultIndex
- The value of prtInputIndex corresponding to the default input sub-unit: that is, this object selects the default source of input media.
- prtInputTable
- A table of the devices capable of providing media for input to the printing process.
- prtInputEntry
- Attributes of a device capable of providing media for input to the printing process. Entries may exist in the table for each device index who's device type is `printer'.
- prtInputIndex
- A unique value used by the printer to identify this input sub-unit. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new input sub-units to the printer), values are expected to remain stable across succes ...
- prtInputType
- The type of technology (discriminated primarily according to feeder mechanism type) employed by the input sub-unit. Note, the Optional Input Class provides for a descriptor field to further qualify the other choice.
- prtInputDimUnit
- The unit of measurement for use calculating and relaying dimensional values for this input sub-unit.
- prtInputMediaDimFeedDirDeclared
- This object provides the value of the declared dimension, in the feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The feed direction is the direction in which the media is fed on this sub-unit. This dimension i ...
- prtInputMediaDimXFeedDirDeclared
- This object provides the value of the declared dimension, in the cross feed direction, of the media that is (or, if empty, was or will be) in this input sub-unit. The cross feed direction is ninety degrees relative to the feed direction associated with ...
- prtInputMediaDimFeedDirChosen
- The printer will act as if media of the chosen dimension (in the feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. Feed dimension measurements are taken parallel relative to the feed direc ...
- prtInputMediaDimXFeedDirChosen
- The printer will act as if media of the chosen dimension (in the cross feed direction) is present in this input source. Note that this value will be used even if the input tray is empty. The cross feed direction is ninety degrees relative to the feed dir ...
- prtInputCapacityUnit
- The unit of measurement for use in calculating and relaying capacity values for this input sub-unit.
- prtInputMaxCapacity
- The maximum capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this value reflects claimed capacity. If this input sub-unit can reliably sense this value, the value i ...
- prtInputCurrentLevel
- The current capacity of the input sub-unit in input sub-unit capacity units (CapacityUnit). If this input sub-unit can reliably sense this value, the value is sensed by the printer and may not be changed by management requests; otherwise, the value may be ...
- prtInputStatus
- The current status of this input sub-unit.
- prtInputMediaName
- A description of the media contained in this input sub-unit; This description is intended for display to a human operator. This description is not processed by the printer. It is used to provide information not expressible in terms of the other media att ...
- prtInputName
- The name assigned to this input sub-unit.
- prtInputVendorName
- The vendor name of this input sub-unit.
- prtInputModel
- The model name of this input sub-unit.
- prtInputVersion
- The version of this input sub-unit.
- prtInputSerialNumber
- The serial number assigned to this input sub-unit.
- prtInputDescription
- A free-form text description of this input sub-unit in the localization specified by prtGeneralCurrentLocalization.
- prtInputSecurity
- Indicates if this input sub-unit has some security associated with it.
- prtInputMediaWeight
- The weight of the medium associated with this input sub-unit in grams / per meter squared. The value (-2) means unknown.
- prtInputMediaType
- The name of the type of medium associated with this input sub-unit. This name need not be processed by the printer; it might simply be displayed to an operator. The standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) are: stationery ...
- prtInputMediaColor
- The name of the color of the medium associated with this input sub-unit using standardized string values from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white pink yellow buff goldenrod blue green transparent Implementors may add additi ...
- prtInputMediaFormParts
- The number of parts associated with the medium associated with this input sub-unit if the medium is a multi-part form. The value (-1) means other and specifically indicates that the device places no restrictions on this parameter. The value (-2) means u ...
- prtOutputDefaultIndex
- The value of prtOutputIndex corresponding to the default output sub-unit; that is, this object selects the default output destination.
- prtOutputTable
- A table of the devices capable of receiving media delivered from the printing process.
- prtOutputEntry
- Attributes of a device capable of receiving media delivered from the printing process. Entries may exist in the table for each device index who's device type is `printer'.
- prtOutputIndex
- A unique value used by this printer to identify this output sub-unit. Although these values may change due to a major reconfiguration of the sub-unit (e.g. the addition of new output devices to the printer), values are expected to remain stable across su ...
- prtOutputType
- The type of technology supported by this output sub-unit.
- prtOutputCapacityUnit
- The unit of measurement for use in calculating and relaying capacity values for this output sub-unit.
- prtOutputMaxCapacity
- The maximum capacity of this output sub-unit in output sub-unit capacity units (CapacityUnit). There is no convention associated with the media itself so this value essentially reflects claimed capacity. If this output sub-unit can reliably sense this val ...
- prtOutputRemainingCapacity
- The remaining capacity of the possible output sub-unit capacity in output sub-unit capacity units (CapacityUnit) of this output sub-unit. If this output sub-unit can reliably sense this value, the value is sensed by the printer and may not be modified by ...
- prtOutputStatus
- The current status of this output sub-unit.
- prtOutputName
- The name assigned to this output sub-unit.
- prtOutputVendorName
- The vendor name of this output sub-unit.
- prtOutputModel
- The name assigned to this output sub-unit.
- prtOutputVersion
- The version of this output sub-unit.
- prtOutputSerialNumber
- The serial number assigned to this output sub-unit.
- prtOutputDescription
- A free-form text description of this output sub-unit in the localization specified by prtGeneralCurrentLocalization.
- prtOutputSecurity
- Indicates if this output sub-unit has some security associated with it and if that security is enabled or not.
- prtOutputDimUnit
- The unit of measurement for use in calculating and relaying dimensional values for this output sub-unit.
- prtOutputMaxDimFeedDir
- The maximum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, th ...
- prtOutputMaxDimXFeedDir
- The maximum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this val ...
- prtOutputMinDimFeedDir
- The minimum dimensions supported by this output sub-unit for measurements taken parallel relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this value, t ...
- prtOutputMinDimXFeedDir
- The minimum dimensions supported by this output sub-unit for measurements taken ninety degrees relative to the feed direction associated with that sub-unit in output sub-unit dimensional units (DimUnit). If this output sub-unit can reliably sense this val ...
- prtOutputStackingOrder
- The current state of the stacking order for the associated output sub-unit. `FirstToLast' means that as pages are output the front of the next page is placed against the back of the previous page. `LasttoFirst' means that as pages are output the back of t ...
- prtOutputPageDeliveryOrientation
- The reading surface that will be `up' when pages are delivered to the associated output sub-unit. Values are Face-Up and Face-Down. (Note: interpretation of these values is in general context-dependent based on locale; presentation of these values to an e ...
- prtOutputBursting
- This object indicates that the outputing sub-unit supports bursting, and if so, whether the feature is enabled. Bursting is the process by which continuous media is separated into individual sheets, typically by bursting along pre-formed perforations.
- prtOutputDecollating
- This object indicates that the output supports supports decollating, and if so, whether the feature is enabled. Decollating is the process by which the individual parts within a multi-part form are separated and sorted into separate stacks for each part.
- prtOutputPageCollated
- This object indicates that the output sub-unit supports page collation, and if so, whether the feature is enabled.
- prtOutputOffsetStacking
- This object indicates that the output supports supports offset stacking, and if so, whether the feature is enabled.
- prtMarkerDefaultIndex
- The value of prtMarkerIndex corresponding to the default markersub-unit; that is, this object selects the default marker.
- prtMarkerTable
- prtMarkerEntry
- Entries may exist in the table for each device index who's device type is `printer'.
- prtMarkerIndex
- A unique value used by the printer to identify this marking SubUnitStatus. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marking sub-units to the printer), values are expected to remain stable acr ...
- prtMarkerMarkTech
- The type of marking technology used for this marking sub-unit.
- prtMarkerCounterUnit
- The unit that will be used by the printer when reporting counter values for this marking sub-unit. The time units of measure are provided for a device like a strip recorder that does not or cannot track the physical dimensions of the media and does not u ...
- prtMarkerLifeCount
- The count of the number of units of measure counted during the life of printer using units of measure as specified by CounterUnit.
- prtMarkerPowerOnCount
- The count of the number of units of measure counted since the equipment was most recently powered on using units of measure as specified by CounterUnit.
- prtMarkerProcessColorants
- The number of process colors supported by this marker. A process color of 1 implies monochrome. The value of this object and SpotColorants cannot both be 0. Must be 0 or greater.
- prtMarkerSpotColorants
- The number of spot colors supported by this marker. The value of this object and ProcessColorants cannot both be 0. Must be 0 or greater.
- prtMarkerAddressabilityUnit
- The unit of measure of distances.
- prtMarkerAddressabilityFeedDir
- The number of addressable marking positions in the feed direction per 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'.
- prtMarkerAddressabilityXFeedDir
- The number of addressable marking positions in the cross feed direction in 10000 units of measure specified by AddressabilityUnit. A value of (-1) implies 'other' or 'infinite' while a value of (-2) implies 'unknown'.
- prtMarkerNorthMargin
- The margin, in units identified by AddressabilityUnit, from the leading edge of the medium as the medium flows throught the marking engine with the side to be imaged facing the observer. The leading edge is the North edge and the other edges are defined b ...
- prtMarkerSouthMargin
- The margin from the South edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown.
- prtMarkerWestMargin
- The margin from the West edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bouned by all four margins is guaranteed for all interpreters. The value (-2) means unknown.
- prtMarkerEastMargin
- The margin from the East edge (see NorthMargin) of the medium in units identified by AddressabilityUnit. Printing within the area bounded by all four margins is guaranteed for all interpreters. The value (-2) means unknown.
- prtMarkerStatus
- The current status of this marker sub-unit.
- prtMarkerSuppliesTable
- A table of the marker supplies available on this printer.
- prtMarkerSuppliesEntry
- Attributes of a marker supply. Entries may exist in the table for each device index who's device type is `printer'.
- prtMarkerSuppliesIndex
- A unique value used by the printer to identify this marker supply. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new marker supplies to the printer), values are expected to remain stable across succes ...
- prtMarkerSuppliesMarkerIndex
- The value of prtMarkerIndex corresponding to the marking sub-unit with which this marker supply sub-unit is associated.
- prtMarkerSuppliesColorantIndex
- The value of prtMarkerColorantIndex corresponding to the colorant with which this marker supply sub-unit is associated. This value shall be 0 if there is no colorant table.
- prtMarkerSuppliesClass
- Indicates whether this supply entity represents a supply container that is consumed or a receptacle that is filled.
- prtMarkerSuppliesType
- The type of this supply.
- prtMarkerSuppliesDescription
- The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization.
- prtMarkerSuppliesSupplyUnit
- Unit of this marker supply container/receptacle.
- prtMarkerSuppliesMaxCapacity
- The maximum capacity of this supply container/receptacle expressed in SupplyUnit. If this supply container/receptacle can reliably sense this value, the value is sensed by the printer and is read-only; otherwise, the value may be written (by a Remote Cont ...
- prtMarkerSuppliesLevel
- The current level if this supply is a container; the remaining space if this supply is a receptacle. If this supply container/receptacle can reliably sense this value, the value is sensed by the printer and is read-only; otherwise, the value may be writte ...
- prtMarkerColorantTable
- A table of all of the colorants available on the printer.
- prtMarkerColorantEntry
- Attributes of a colorant available on the printer. Entries may exist in the table for each device index who's device type is `printer'.
- prtMarkerColorantIndex
- A unique value used by the printer to identify this colorant. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new colorants to the printer), values are expected to remain stable across successive printer ...
- prtMarkerColorantMarkerIndex
- The value of prtMarkerIndex corresponding to the marker sub-unit with which this colorant entry is associated.
- prtMarkerColorantRole
- The role played by this colorant.
- prtMarkerColorantValue
- The name of the color of this The name of the color of this colorant using standardized string names from ISO 10175 (DPA) and ISO 10180 (SPDL) which are: other unknown white red green blue cyan magenta yellow black Implementors may add additional string v ...
- prtMarkerColorantTonality
- The distinct levels of tonality realizable by a marking sub-unit when using this colorant. This value does not include the number of levels of tonal difference that an interpreter can obtain by techniques such as half toning. This value must be at least ...
- prtMediaPathDefaultIndex
- The value of prtMediaPathIndex corresponding to the default media path; that is, the selection of the default media path.
- prtMediaPathTable
- prtMediaPathEntry
- Entries may exist in the table for each device index who's device type is `printer'.
- prtMediaPathIndex
- A unique value used by the printer to identify this media path. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new media paths to the printer), values are expected to remain stable across successive pri ...
- prtMediaPathMaxSpeedPrintUnit
- The unit of measure used in specifying the speed of all media paths in the printer.
- prtMediaPathMediaSizeUnit
- The units of measure of media size for use in calculating and relaying dimensional values for all media paths in the printer.
- prtMediaPathMaxSpeed
- The maximum printing speed of this media path expressed in prtMediaPathMaxSpeedUnit's. A value of (-1) implies 'other'.
- prtMediaPathMaxMediaFeedDir
- The maximum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-1) implies 'unlimited'. A value of (-2) implies 'unknown'
- prtMediaPathMaxMediaXFeedDir
- The maximum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'.
- prtMediaPathMinMediaFeedDir
- The minimum physical media size in the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'.
- prtMediaPathMinMediaXFeedDir
- The minimum physical media size across the feed direction of this media path expressed in units of measure specified by MediaSizeUnit. A value of (-2) implies 'unknown'.
- prtMediaPathType
- The type of the media path for this media path.
- prtMediaPathDescription
- The manufacturer-provided description of this media path in the localization specified by prtGeneralCurrentLocalization.
- prtMediaPathStatus
- The current status of this media path.
- prtChannelTable
- prtChannelEntry
- Entries may exist in the table for each device index who's device type is `printer'.
- prtChannelIndex
- A unique value used by the printer to identify this data channel. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new data channels to the printer), values are expected to remain stable across successiv ...
- prtChannelType
- The type of this print data channel. This object provides the linkage to ChannelType-specific groups that may (conceptually) extend the prtChannelTable with additional details about that channel.
- prtChannelProtocolVersion
- The version of the protocol used on this channel. The format used for version numbering depends on prtChannelType.
- prtChannelCurrentJobCntlLangIndex
- The value of prtInterpreterIndex corresponding to the Control Language Interpreter for this channel. This interpreter defines the syntax used for control functions, such as querying or changing environment variables and identifying job boundaries (e.g. P ...
- prtChannelDefaultPageDescLangIndex
- The value of prtInterpreterIndex corresponding to the Page Description Language Interpreter for this channel. This interpreter defines the default Page Description Language interpreter to be used for the print data unless the Control Language is used to ...
- prtChannelState
- The state of this print data channel. The value determines whether control information and print data is allowed through this channel or not.
- prtChannelIfIndex
- The value of ifIndex (in the ifTable; see the interface section of MIB-2/RFC 1213) which corresponds to this channel. When more than one row of the ifTable is relevant, this is the index of the row representing the topmost layer in the interface hierarchy ...
- prtChannelStatus
- The current status of the channel.
- prtInterpreterTable
- prtInterpreterEntry
- Entries may exist in the table for each device index who's device type is `printer'.
- prtInterpreterIndex
- A unique value for each PDL or control language for which there exists an interpreter or emulator in the printer. The value is used to identify this interpreter. Although these values may change due to a major reconfiguration of the device (e.g. the addi ...
- prtInterpreterLangFamily
- The family name of a Page Description Language (PDL) or control language which this interpreter in the printer can interpret or emulate. This type 2 list of enumerations requires review before additional entries are made.
- prtInterpreterLangLevel
- The level of the language which this interpreter is interpreting or emulating. This might contain a value like '5e' for an interpreter which is emulating level 5e of the PCL language. It might contain '2' for an interpreter which is emulating level 2 of ...
- prtInterpreterLangVersion
- The date code or version of the language which this interpreter is interpreting or emulating.
- prtInterpreterDescription
- A string to identify this interpreter in the localization specified by prtGeneralCurrentLocalization as opposed to the language which is being interpreted. It is anticipated that this string will allow manufacturers to unambiguously identify their interp ...
- prtInterpreterVersion
- The date code, version number, or other product specific information tied to this interpreter. This value is associated with the interpreter, rather than with the version of the language which is being interpreted or emulated.
- prtInterpreterDefaultOrientation
- The current orientation default for this interpreter. This value may be overridden for a particular job (e.g., by a command in the input data stream).
- prtInterpreterFeedAddressability
- The maximum interpreter addressability in the feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityFeedDir ) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restrictions ...
- prtInterpreterXFeedAddressability
- The maximum interpreter addressability in the cross feed direction in 10000 prtMarkerAddressabilityUnit s (see prtMarkerAddressabilityXFeedDir) for this interpreter. The value (-1) means other and specifically indicates that the sub-unit places no restric ...
- prtInterpreterDefaultCharSetIn
- The default coded character set for input octets encountered outside a context in which the Page Description Language established the interpretation of the octets. This value shall be (2) if there is no default.
- prtInterpreterDefaultCharSetOut
- The default character set for data coming from this interpreter through the printer's output channel. This value shall be (2) if there is no default.
- prtInterpreterTwoWay
- Indicates whether or not this interpreter returns information back to the host.
- prtConsoleLocalization
- The value of the prtLocalizationIndex corresponding to the language, country, and character set to be used for the console. This localization applies both to the actual display on the console as well as the encoding of these console objects in management ...
- prtConsoleNumberOfDisplayLines
- The number of lines on the printer's physical display. This value is 0 if there are no lines on the physical display or if there is no physical display
- prtConsoleNumberOfDisplayChars
- The number of characters per line displayed on the physical display. This value is 0 if there are no lines on the physical display or if there is no physical display
- prtConsoleDisable
- This object enables or disables manual input from the operators console.
- prtConsoleDisplayBufferTable
- prtConsoleDisplayBufferEntry
- This table contains one entry for each physical line on the display. Lines cannot be added or deleted. Entries may exist in the table for each device index who's device type is `printer'.
- prtConsoleDisplayBufferIndex
- A unique value for each console line in the printer. The value is used to identify this console line. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new console lines to the printer), values are expect ...
- prtConsoleDisplayBufferText
- The content of a line in the logical display buffer of the operator's console of the printer. When a write operation occurs, normally a critical message, to one of the LineText strings, the agent should make that line displayable if a physical display is ...
- prtConsoleLightTable
- prtConsoleLightEntry
- Entries may exist in the table for each device index who's device type is `printer'.
- prtConsoleLightIndex
- A unique value used by the printer to identify this light. Although these values may change due to a major reconfiguration of the device (e.g. the addition of new lights to the printer), values are expected to remain stable across successive printer power ...
- prtConsoleOnTime
- The on time in milliseconds of blinking of this light; 0 indicates off always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always off.
- prtConsoleOffTime
- The off time in milliseconds of blinking of this light; 0 indicates on always. If both prtConsoleOnTime and prtConsoleOffTime are 0, then the light is always off.
- prtConsoleColor
- The color of this light.
- prtConsoleDescription
- The vendor description or label of this light in the localization specified by prtConsoleLocalization.
- prtAlertTable
- prtAlertEntry
- Entries may exist in the table for each device index who's device type is `printer'.
- prtAlertIndex
- The index value used to determine which alerts have been added or removed from the alert table. This is an incrementing integer starting from zero every time the printer is reset. When the printer adds an alert to the table, that alert is assigned the ne ...
- prtAlertSeverityLevel
- The level of severity of this alert table entry. The printer determines the severity level assigned to each entry into the table.
- prtAlertTrainingLevel
- The level of training required to handle this alert. The training level is an enumeration that is determined and assigned by the printer manufacturer based on the information or the training required to handle this alert. The printer will break alerts in ...
- prtAlertGroup
- The type of sub-unit within the printer model that this alert is related. Input, output, and markers are examples of printer model groups, i.e., examples of types of sub-units. Whereever possible, these enumerations match the sub-identifier that identifi ...
- prtAlertGroupIndex
- An index of the row within the principle table in the group identified by prtAlertGroup that represents the sub-unit of the printer that caused this alert. The combination of the Group and the GroupIndex defines exactly which printer sub-unit caused the ...
- prtAlertLocation
- The sub-unit location that is defined by the printer manufacturer to further refine the location of this alert within the designated sub-unit. The location is used in conjunction with the Group and GroupIndex values; for example, there is an alert in Inp ...
- prtAlertCode
- The code that describes the type of alert for this entry in the table. There are different codes for each sub-unit type: for example, Media Supply Low and Media Supply Empty are Aler codes for the Input sub-unit.
- prtAlertDescription
- A description of this alert entry in the localization specified by prtGeneralCurrentLocalization. The description is provided by the printer to further elaborate on the enumerated alert or provide information in the case where the code is classified ask ...
- printerV1Alert
- The value of the enterprise-specific oid in a SNMPv1 trap sent signalling a critical event in the prtAlertTable.
- prtAlertTime
- The value of sysUpTime at the time that this alert was generated.
- prtGeneralGroup
- The general printer group.
- prtResponsiblePartyGroup
- The responsible party group contains contact information for humans responsible for the printer.
- prtInputGroup
- The input group.
- prtExtendedInputGroup
- The extended input group.
- prtInputMediaGroup
- The input media group.
- prtOutputGroup
- The output group.
- prtExtendedOutputGroup
- The extended output group.
- prtOutputDimensionsGroup
- The output dimensions group
- prtOutputFeaturesGroup
- The output features group.
- prtMarkerGroup
- The marker group.
- prtMarkerSuppliesGroup
- The marker supplies group.
- prtMarkerColorantGroup
- The marker colorant group.
- prtMediaPathGroup
- The media path group.
- prtChannelGroup
- The channel group.
- prtInterpreterGroup
- The interpreter group.
- prtConsoleGroup
- The console group.
- prtAlertTableGroup
- The alert table group.
- prtAlertTimeGroup
- The alert time group.
Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.
Witn IPHost SNMP monitor you can monitor network performance, audit network usage, detect network faults, or inappropriate access.
The IPHost's SNMP monitor can communicate and interact with any SNMP-enabled device.