ups_volts - SNMP monitoring

MIBs list

SNMP OIDs - ups_volts

The objects described here can be monitored with the IPHost Network Monitor. You can start SNMP monitoring using free 30-day trial version of IPHost right now.

OID list for ups volts

Cabletron Ups AC Line Volts In
ctUpsACLineVoltsIn 1.3.6.1.4.1.52.4.1.5.4.1.7 (defined in ctron-ups-mib)
Denotes the input AC utility line voltage.
Cabletron Ups Battery Volts Out
ctUpsBatteryVoltsOut 1.3.6.1.4.1.52.4.1.5.4.1.8 (defined in ctron-ups-mib)
Denotes the battery voltage.
ld Ups Input Max Volts Since Last Poll
ldUpsInputMaxVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.3.1 (defined in LIEBERT-UPSTATION-D-UPS-MIB)
The maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
ld Ups Input Min Volts Since Last Poll
ldUpsInputMinVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.3.2 (defined in LIEBERT-UPSTATION-D-UPS-MIB)
The minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
ld Ups Output Max Volts Since Last Poll
ldUpsOutputMaxVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.4.1 (defined in LIEBERT-UPSTATION-D-UPS-MIB)
The maximum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
ld Ups Output Min Volts Since Last Poll
ldUpsOutputMinVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.4.2 (defined in LIEBERT-UPSTATION-D-UPS-MIB)
The minimum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
ld Ups Input Max Volts Since Last Poll
ldUpsInputMaxVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.3.1 (defined in LIEBERT-UPS-MIB)
The maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
ld Ups Input Min Volts Since Last Poll
ldUpsInputMinVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.3.2 (defined in LIEBERT-UPS-MIB)
The minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
ld Ups Output Max Volts Since Last Poll
ldUpsOutputMaxVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.4.1 (defined in LIEBERT-UPS-MIB)
The maximum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.
ld Ups Output Min Volts Since Last Poll
ldUpsOutputMinVoltsSinceLastPoll 1.3.6.1.4.1.476.1.1.1.3.4.2 (defined in LIEBERT-UPS-MIB)
The minimum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated.

MIBs list