ALCATEL-IND1-CHASSIS-MIB

ALCATEL-IND1-CHASSIS-MIB Download

MIBs list

This module describes an authoritative enterprise-specific Simple etwork Management Protocol (SNMP) Management Information Base (MIB): For the Birds Of Prey Product Line, this is the Chassis Supervision Chassis MIB for managing physical chassis objects not covered in the IETF Entity MIB (rfc 2737). The right to make changes in specification and other information contained in this document without prior notice is reserved. No liability shall be assumed for any incidental, indirect, special, or consequential damages whatsoever arising from or related to this document or the information contained herein. Vendors, end-users, and other interested parties are granted non-exclusive license to use this specification in connection with management of the products for which it is intended to be used.

IPHost Network Monitor offer an easy way of SNMP monitoring your Alcatel Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for ALCATEL-IND1-CHASSIS-MIB

alcatelIND1ChassisMIBObjects
Branch For Chassis Supervision Chassis MIB Subsystem Managed Objects.
alcatelIND1ChassisMIBConformance
Branch For Chassis Supervision Chassis MIB Subsystem Conformance Information.
alcatelIND1ChassisMIBGroups
Branch For Chassis Supervision Chassis MIB Subsystem Units Of Conformance.
alcatelIND1ChassisMIBCompliances
Branch For Chassis Supervision Chassis MIB Subsystem Compliance Statements.
alcatelIND1ChassisPhysMIBObjects
Branch For Chassis Supervision Chassis Physical MIB Subsystem Managed Objects.
alcatelIND1ChassisPhysMIBConformance
Branch For Chassis Supervision Chassis Physical MIB Subsystem Conformance Information.
alcatelIND1ChassisPhysMIBGroups
Branch For Chassis Supervision Chassis Physical MIB Subsystem Units Of Conformance.
alcatelIND1ChassisPhysMIBCompliances
Branch For Chassis Supervision Chassis Physical MIB Subsystem Compliance Statements.
chasControlModuleTable
This table contains one row for the primary control module.
chasControlModuleEntry
Information about the primary control module. This table is an extension of the entity physical table but this class is instanciated only for a the primary control module that has a particular Index.
chasControlRunningVersion
Identification of the Running Version (or Running Configuration) for the control module. Note that the Running Version value of (1) unknown, (2) working, or (3) certified is returned.
chasControlActivateTimeout
This value is in seconds. It represents how much time before the switch automatically falls back to the certified version. This value is set via the Activate(reload working) cli command. An Activate reboot must be initiated via the primary CMM and that th ...
chasControlVersionMngt
For the primary this means: notSignificant - No command applied. certifySynchro - Copy the file from the working to the certified directory and from the primary to the secondary (reboot of the secondary). certifyNoSynchro - Copy the file from the working ...
chasControlDelayedActivateTimer
Timer value in seconds used to initiate a delayed activate of the primary CMM. Writing this object to a non-zero value results in CMM reboot of the working directory following expiration of the specified activate timer delay. Writing this object to zero ...
chasControlRedundantTable
This table contains one row per control module. There is always at least one control module in the system.
chasControlRedundantEntry
Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index.
chasControlNumberOfTakeover
This object is a count of the number of times the control module has changed from primary to secondary mode as a result of a Takeover. Note that this object can be accessed via user interface to either the primary or secondary CMM. The value returned is t ...
chasControlDelayedRebootTimer
Timer value (in seconds) used to initiate a delayed reboot of the primary or secondary CMM using the certified configuration. Writing this object to a non-zero value results in a CMM reboot following expiration of the specified reset timer delay. Writin ...
chasChassisTable
This table contains one row per chassis. There is always at least one chassis or many like for stackable product.
chasChassisEntry
Information about a particular control module this table is an extension of the entity physical table but this class is instanciated only for a particular type of physical entity: the control module that has a particular Index.
chasFreeSlots
The number of free NI front panel slots.
chasPowerLeft
The power still available on the chassis in Watts.
chasNumberOfResets
This object is a count of the number of times this station has been reset since a cold-start.
chasHardwareBoardTemp
This object indicates the current output of the Board Temperature Sensor provided by the LM75 part (degrees Centigrade) for this chassis. This temperature is what is used for comparing to the threshold and determining whether the value is in range.
chasHardwareCpuTemp
This object indicates the current output of the SPARC Temperature Sensor (degrees Centigrade) for this chassis.
chasTempRange
Temp Range is the value of the temperature sensor for the chassis. The Temp Range value reflects the temperature of the chassis relative to the Temp Threshold value (i.e., over vs. under the threshold).
chasTempThreshold
This object is the threshold temperature in degrees Celsius for the chassis. Temp Threshold is the chassis temperature point at which, when reached due to an ascending or descending temperature transition, a temperature notification is provided to the use ...
chasDangerTempThreshold
This Threshold is a second one which is hardcoded. When the Chassis Exceeds this value it starts shutting down NIs. This value will be set by the factory and not changeable.
chasPrimaryPhysicalIndex
This value holds the Entity Table Physical Index for the Control Module that is currently primary. This is to allow snmp managers to determine which Control Module is currently primary so it knows what entry in the chasControlModuleTable to access for set ...
chasEntPhysicalTable
This table contains one row per physical entity. It is an extension for the entity physical table (rfc 2737) that is instantiated for every physical entity object. The fields are not always significant for every object.
chasEntPhysicalEntry
Information about a particular physical entity.
chasEntPhysAdminStatus
All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value: powerOn <=> powered up Control Module possible value: powerOn <=> CM up and running reset <=> CM reset takeover <=> Secondary CM takes ove ...
chasEntPhysOperStatus
All modules (even empty slots) are in unknown state when the chassis first powers up. Chassis status possible value : up <=> powered up Control Module possible value : notPresent <=> CM not present up <=> CM up and running down <=> CM down and powered sec ...
chasEntPhysLedStatus
The status of each of the LEDs of this module. Falcon CMM: [11] Fan 1=Green (ok) 0=amber (fail) [10] Temperature 1=Green (ok) 0=amber (fail) [9] Secondary CMM 1=amber 0=OFF [8] Primary CMM 1=amber 0=OFF [7:6] OK2 amber 00=off 01=on 1 ...
chasEntPhysPower
This value is only applicable to the NI, PS and Control Modules. It corresponds to a a static value for the power consumption of an NI module or Control Module. This value is in Watts.
chasEntPhysModuleType
This object is the unique Module Type or ID from the entities eeprom. This value is guarrantteed to be unique to each type of Module. This value is only intended for Alcatel internal use.
chasEntPhysMfgDate
This object contains the manufacturing date of the entity. Its format is mmm dd yyyy : NOV 27 2001.
chasEntPhysPartNumber
This object contains the Alcatel Part Number for the entity. This value is used to identify what is needed when placing orders with Alcatel.
chassisTrapsStrLevel
An enumerated value which provides the urgency level of the STR.
chassisTrapsStrAppID
Application Identification number
chassisTrapsStrSnapID
Subapplication Identification number. we can have multiple snapIDs per Subapplication (task) but only one is to be used to send STRs.
chassisTrapsStrfileName
Name of the source file where the fault was detected. This is given by the C ANSI macro __FILE__. The path shouldn't appear.
chassisTrapsStrfileLineNb
Line number in the source file where the fault was detected. This is given by the C ANSI macro __LINE__.
chassisTrapsStrErrorNb
Fault identificator. The error number identify the kind the detected fault and allow a mapping of the data contained in chassisTrapsdataInfo.
chassisTrapsStrcomments
comment text explaning the fault.
chassisTrapsStrdataInfo
Additional data provided to help to find out the origine of the fault. The contain and the significant portion are varying in accordance with chassisTrapsStrErrorNb. The lenght of this field is expressed in bytes.
chassisTrapsObjectType
enumerated value which provide the object type involved in the alert trap.
chassisTrapsObjectNumber
number defining the order of the object in the set. EX: number of the considered fan or power supply. This intend to clarify as much as possible the location of the failure or alert. A instance of the appearance of the trap could be: failure on a module. ...
chassisTrapsAlertNumber
this number identify the alert among all the possible chassis alert causes.
chassisTrapsAlertDescr
description of the alert maching chassisTrapsAlertNumber
physicalIndex
The Physical index of the involved object.
chasControlModuleGroup
Chassis Supervision Control Modules (CMM) Group.
chasControlRedundantGroup
Chassis Supervision Redundant Control Modules (CMM) Group.
chasChassisGroup
Chassis Supervision Chassis Group.
chasEntPhysicalGroup
Chassis (inclosure) Entity Physical Group.