CISCO-DSPU-MIB

CISCO-DSPU-MIB Download

MIBs list

Used to define and manage DSPU objects.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-DSPU-MIB

dspuNodeRsrb
RSRB feature enabled/disabled for the DSPU node. TRUE -> RSRB feature enabled FALSE -> RSRB feature disabled If the RSRB feature is enabled, the following object values must be valid (i.e. non-zero): - dspuNodeRsrbLocalVirtualRing - dspuNodeRsrbBridgeNum ...
dspuNodeRsrbLocalVirtualRing
Local virtual ring number used by the DSPU node. LocalVirtualRing is zero if RSRB is not enabled.
dspuNodeRsrbBridgeNumber
Bridge number connecting the DSPU LocalVirtualRing with the RSRB TargetVirtualRing. Currently, the only valid BridgeNumber supported is 1. BridgeNumber must be one if RSRB is enabled. BridgeNumber is zero if RSRB is not enabled.
dspuNodeRsrbTargetVirtualRing
Target virtual ring number used for RSRB. TargetVirtualRing is zero if RSRB is not enabled.
dspuNodeRsrbVirtualMacAddress
Virtual MAC address of the the DSPU node. VirtualMacAddress is zero if RSRB is not enabled.
dspuNodeDefaultPu
Default-PU feature enabled/disabled for the DSPU node. TRUE -> Default-PU feature enabled FALSE -> Default-PU feature disabled
dspuNodeDefaultPuWindowSize
Send/receive window size to be used across the link between the default-PU and a remote PU.
dspuNodeDefaultPuMaxIframe
Maximum size of an I-frame that can be transmitted/received across the link between the default-PU and a remote PU.
dspuNodeActivationWindow
Activation pacing window used by the DSPU node to limit the number of activation RUs sent for a given SAP before waiting for responses from the remote.
dspuNodeLastConfigChgTime
Timestamp of last change to DSPU configuration parameters. LastConfigChgTime reflects any change in DSPU configuration.
dspuPoolClassTable
Table listing defined pool classes for the DSPU node. A pool class is defined at the DSPU node as a pool of upstream LUs that may be shared among downstream PUs. Each entry in the table represents a separate pool class definition. Entries in the table may ...
dspuPoolClassEntry
Each entry represents a defined pool class.
dspuPoolClassIndex
Index of a pool class entry in the dspuPoolClassTable.
dspuPoolClassName
Name identifier of the pool class.
dspuPoolClassInactivityTimeout
Value (in minutes) of the inactivity timeout that will be applied to active LU sessions assigned from the pool class. The inactivity timeout feature for pooled LUs is disabled if the InactivityTimeout value is zero.
dspuPoolClassOperUpStreamLuDefs
Number of upstream LUs defined in the pool class.
dspuPoolClassOperDnStreamLuDefs
Number of downstream LUs defined in the pool class.
dspuPooledLuTable
Table listing all LUs defined in a specified pool class. The entries in the table provide information such that the downstream LUs in the pool can be correlated with the upstream LUs to which they may be assigned and vice versa. If all upstream LUs have b ...
dspuPooledLuEntry
Each entry represents an LU that is defined as a member of the specified pool class.
dspuPooledLuPeerPuIndex
Index (dspuPuOperIndex) of the peer PU that owns the peer LU. PeerPuIndex is zero if peer LU has not been assigned.
dspuPooledLuPeerLuLocalAddress
NAU address (dspuLuOperLuLocalAddress) of the peer LU. PeerLuLocalAddress is zero if peer LU has not been assigned.
dspuPuAdminTable
Table listing all defined upstream/downstream PUs that are owned by the DSPU node. NOTE: The dspuPuAdminTable does not include default downstream PUs that may be dynamically created.
dspuPuAdminEntry
Each entry represents a defined upstream/downstream PU.
dspuPuAdminIndex
Index of the PU entry in the dspuPuAdminTable.
dspuPuAdminName
Name of the PU.
dspuPuAdminType
PU Type is either upstream or downstream.
dspuPuAdminRemoteMacAddress
MAC address of the remote PU.
dspuPuAdminRemoteSapAddress
SAP address of the remote PU.
dspuPuAdminLocalSapAddress
SAP address of the local PU.
dspuPuAdminXid
Upstream PU : XID that will be sent to the remote PU. Dnstream PU : XID that must be received from the remote PU.
dspuPuAdminXidFmt
Type of XID format used during activation of the link between this dspuNode and the remote PU.
dspuPuAdminWindowSize
Send/Receive window size to be used across the link between this dspuNode and the remote PU.
dspuPuAdminMaxIframe
Maximum size of an I-frame that can be transmitted/received across the link between this dspuNode and the remote PU.
dspuPuAdminLinkRetryCount
Number of times that the DSPU node will attempt to activate the link between the dspuNode and the remote PU.
dspuPuAdminLinkRetryTimeout
Value (in seconds) for the delay between link activation attempts between the dspuNode and the remote PU.
dspuPuAdminStartPu
Attempt link activation with the remote PU. TRUE -> Attempt link activation with remote PU. FALSE -> Do not attempt link activation with remote PU.
dspuPuAdminDlcType
DLC type used by the dspuNode for link activation with the remote PU.
dspuPuAdminDlcUnit
DLC unit used by the dspuNode for link activation with the remote PU.
dspuPuAdminDlcPort
DLC port used by the dspuNode for link activation with the remote PU.
dspuPuAdminFocalPoint
PU serves as a focal point for alert forwarding. TRUE -> PU serves as focal point FALSE -> PU does not serve as focal point Only an upstream PU may be defined as a focal point. Downstream PUs can never be defined as a focal point; FocalPoint is always FA ...
dspuPuAdminRowStatus
Used by a Management Station to create or delete the row entry in the dspuPuAdminTable following the RowStatus textual convention. Upon successful creation of the row, an Agent automatically creates a corresponding entry in the dspuPuOperTable. The Manage ...
dspuPuAdminRemoteAddress
Poll address, DLCI, or subscriber address associated with the remote PU.
dspuPuOperTable
Table listing all active upstream/downstream PUs that are owned by the DSPU node (including default PUs). NOTE: In addition to the explicitly defined PUs from the dspuPuAdminTable, the dspuPuOperTable also includes default downstream PUs that may be dynam ...
dspuPuOperEntry
Each entry represents an active upstream/downstream PU.
dspuPuOperIndex
Index of the PU entry in dspuPuOperTable.
dspuPuOperName
Name of the PU.
dspuPuOperType
PU type is either upstream or downstream.
dspuPuOperRemoteMacAddress
MAC address of the remote PU.
dspuPuOperRemoteSapAddress
SAP address of the remote PU.
dspuPuOperLocalSapAddress
SAP address of the local PU.
dspuPuOperXid
Upstream PU : XID that was sent to the remote PU. Dnstream PU : XID that was received from the remote PU.
dspuPuOperXidFmt
Type of XID format used during activation of the link between this dspuNode and the remote PU.
dspuPuOperWindowSize
Send/Receive window size to be used across the link between this dspuNode and the remote PU.
dspuPuOperMaxIframe
Maximum size of an I-frame that can be transmitted/received across the link between this dspuNode and the remote PU.
dspuPuOperLinkRetryCount
Number of times that the DSPU node will attempt to activate the link between the dspuNode and the remote PU.
dspuPuOperLinkRetryTimeout
Value (in seconds) for the delay between link activation attempts between the dspuNode and the remote PU.
dspuPuOperStartPu
Attempt link activation with the remote PU. TRUE -> Attempt link activation with remote PU. FALSE -> Do not attempt link activation with remote PU.
dspuPuOperDlcType
DLC type used by the dspuNode for link activation with the remote PU.
dspuPuOperDlcUnit
DLC unit used by the dspuNode for link activation with the remote PU.
dspuPuOperDlcPort
DLC port used by the dspuNode for link activation with the remote PU.
dspuPuOperFocalPoint
PU serves as a focal point for alert forwarding. TRUE -> PU serves as focal point FALSE -> PU does not serve as focal point Only an upstream PU may be defined as a focal point. Downstream PUs can never be defined as a focal point; FocalPoint is always FA ...
dspuPuOperState
Operational state of PU is either active or inactive.
dspuPuOperFsmState
Current FSM state of the PU as follows: linkReset - Link is in reset state - not connected linkPendConnOut - Pending ConnectOut to establish link linkPendConnIn - Pending ConnectIn to establish link linkPendXid - Pending XID negotiation on the link linkXi ...
dspuPuOperStartTime
Timestamp of PU activation (when ACTPU +rsp received).
dspuPuOperLastStateChgTime
TimeStamp of last PU state change between active<->inactive.
dspuPuOperRemoteAddress
Poll address, DLCI, or subscriber address associated with the remote PU.
dspuPuStatsTable
Table listing the statistics recorded for each PU.
dspuPuStatsEntry
Each entry represents an active upstream/downstream PU and has a corresponding entry in the dspuPuOperTable.
dspuPuStatsSentBytes
Number of bytes sent by this PU.
dspuPuStatsRcvdBytes
Number of bytes received by this PU.
dspuPuStatsSentFrames
Number of frames sent by this PU.
dspuPuStatsRcvdFrames
Number of frames received by this PU.
dspuPuStatsSentNegativeRsps
Number of negative responses sent by this PU.
dspuPuStatsRcvdNegativeRsps
Number of negative responses received by this PU.
dspuPuStatsActiveLus
Number of active LUs on this PU (LU becomes active when ACTLU +rsp received).
dspuPuStatsInactiveLus
Number of inactive LUs on this PU (LU is inactive until ACTLU rq or ACTLU +rsp received).
dspuPuStatsBindLus
Number of LUs on this PU which are active-in-session. (LU is active-in-session when BIND rq received)
dspuPuStatsActivationFailures
Number of activation failures for this PU.
dspuPuStatsLastActivationFailureReason
Reason for last activation failure of this PU as follows: noError - No PU activation failure has been detected otherError - Undefined error detected during PU activation internalError - Internal resources error detected during PU activation configurationE ...
dspuLuAdminTable
Table listing all LUs owned by the PU. NOTE: The dspuLuAdminTable does not include LUs owned by default downstream PUs that may be dynamically created.
dspuLuAdminEntry
Each entry represents a defined LU owned by the PU.
dspuLuAdminLuLocalAddress
NAU address of the local LU.
dspuLuAdminType
LU type is either pooled or dedicated.
dspuLuAdminPoolClassName
Pool class to which the LU is defined as a member. The dspuLuAdminPoolClassName is valid for pooled LUs only.
dspuLuAdminPeerPuIndex
For downstream LUs, the PeerPuIndex identifies the upstream PU that owns the upstream LU to which this downstream LU is assigned. For upstream LUs, the PeerPuIndex identifies the downstream PU that owns the downstream LU to which this upstream LU is assig ...
dspuLuAdminPeerLuLocalAddress
For downstream LUs, the PeerLuLocalAddress identifies the NAU address of the upstream LU to which this downstream LU is assigned. For upstream LUs, the PeerLuLocalAddress identifies the NAU address of the downstream LU to which this upstream LU is assigne ...
dspuLuAdminRowStatus
Used by a Management Station to create or delete the row entry in the dspuLuAdminTable following the RowStatus textual convention. Upon successful creation of the row, an Agent automatically creates a corresponding entry in the dspuLuOperTable. The Manage ...
dspuLuOperTable
Table listing all LUs owned by the PU. NOTE: In addition to the LUs owned by explicitly defined PUs from the dspuLuAdminTable, the dspuLuOperTable also includes the LUs owned by default downstream PUs that may be dynamically created.
dspuLuOperEntry
Each entry represents a defined LU owned by the PU.
dspuLuOperLuLocalAddress
NAU address of the local LU.
dspuLuOperType
LU type is either pooled or dedicated.
dspuLuOperPoolClassName
Pool class to which the LU is defined as a member. The dspuLuOperPoolClassName is valid for pooled LUs only.
dspuLuOperPeerPuIndex
For downstream LUs, the PeerPuIndex identifies the upstream PU that owns the upstream LU to which this downstream LU is assigned. For upstream LUs, the PeerPuIndex identifies the downstream PU that owns the downstream LU to which this upstream LU is assig ...
dspuLuOperPeerLuLocalAddress
For downstream LUs, the PeerLuLocalAddress identifies the NAU address of the upstream LU to which this downstream LU is assigned. For upstream LUs, the PeerLuLocalAddress identifies the NAU address of the downstream LU to which this upstream LU is assigne ...
dspuLuOperState
Operational state of LU is either active or inactive.
dspuLuOperFsmState
Current FSM state of the LU as follows: reset - neither dnLu or upLu active dnLuStarted - dnLu active, upLu inactive upLuActive - upLu active, dnLu inactive dnLuPendAct - dnLu pending activation, upLu active-unavailable dnLuActUnav - dnLu active-unavailab ...
dspuLuOperSessionState
Operational state of LU session is either bound or unbound.
dspuLuOperLastActivationFailureReason
Reason for last activation failure of this PU as follows: noError - No LU activation failure has been detected otherError - Undefined error detected during LU activation luNegativeResponse - Negative ACTLU response received from remote LU
dspuSapTable
Table listing the SAPs that are enabled for the DSPU node.
dspuSapEntry
Each entry represents an enabled SAP for the DSPU node.
dspuSapAddress
SAP address of the local SAP.
dspuSapType
Local SAP type is either upstreamSap or downstreamSap.
dspuSapDlcType
DLC type of the adapter that owns the local SAP.
dspuSapDlcUnit
DLC unit of the adapter that owns the local SAP.
dspuSapDlcPort
DLC port of the adapter that owns the local SAP.
dspuSapOperState
Operational state of the local SAP as follows: - sapClosed - sapOpening - sapOpened - sapClosing
dspuSapRowStatus
This object is used by a Management Station to create or delete the row entry in the dspuSapTable following the RowStatus textual convention. The Management Station can set the value to 'destroy (6)' and the Agent will then delete the rows corresponding t ...
dspuNodeGroup
Global DSPU node information
dspuPoolClassGroup
LU pool class information
dspuPooledLuGroup
Pooled LU information
dspuPuGroup
Upstream/Downstream PU node information
dspuLuGroup
Upstream/Downstream LU information
dspuSapGroup
Local SAP information
dspuPuGroupV11R01
Upstream/Downstream PU node information
dspuLuGroupV11R01
Upstream/Downstream LU information

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.

MIBs list