CISCO-ENTITY-ALARM-MIB

CISCO-ENTITY-ALARM-MIB Download

MIBs list

This MIB module defines the managed objects that support the monitoring of alarms generated by physical entities contained by the system, including chassis, slots, modules, ports, power supplies, and fans. In order to monitor alarms generated by a physical entity, it must be represented by a row in the entPhysicalTable (see ENTITY-MIB).

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-ENTITY-ALARM-MIB

ceAlarmDescrMapTable
For each type of entity (represented entPhysicalVendorType OID), this table contains a mapping between a unique ceAlarmDescrIndex and entPhysicalvendorType OID.
ceAlarmDescrMapEntry
A mapping between an alarm description and a vendor type.
ceAlarmDescrIndex
This object uniquely identifies an alarm description.
ceAlarmDescrVendorType
This object specifies an object identifier (typically an enterprise-specific OID) that uniquely identifies the vendor type of those physical entities that this alarm description applies to.
ceAlarmDescrTable
This table contains a description for each alarm type defined by each vendor type employed by the system. Observe that this table is sparse in nature, as it is rarely the case that a physical entity type needs to define every alarm in its alarm space.
ceAlarmDescrEntry
A collection of attributes that describe an alarm type.
ceAlarmDescrAlarmType
This object specifies the alarm type being described.
ceAlarmDescrSeverity
This object specifies the severity associated with the alarm type. An implementation may chose to not allow dynamic severity assignment, in which case it would restrict access to this object to be read-only. If an implementation allows dynamic severity as ...
ceAlarmDescrText
This object specifies a human-readable message describing the alarm.
ceAlarmCriticalCount
The value of this object specifies the number of alarms currently asserted with a severity of 'critical'.
ceAlarmMajorCount
The value of this object specifies the number of alarms currently asserted with a severity of 'major'.
ceAlarmMinorCount
The value of this object specifies the number of alarms currently asserted with a severity of 'minor'.
ceAlarmCutOff
If the management client writes a value of 'true' to this object, the agent stops signalling all external audible alarms under the control of the agent. Reading this object should always result in a value of 'false'. Observe that alarm cutoff does not ha ...
ceAlarmTable
This table specifies alarm control and status information related to each physical entity contained by the system, including the alarms currently being asserted by each physical entity capable of generating alarms.
ceAlarmEntry
Alarm control and status information related to the corresponding physical entity, including a list of those alarms currently being asserted by that physical entity.
ceAlarmFilterProfile
This object specifies the alarm filter profile associated with the corresponding physical entity. An alarm filter profile controls which alarm types the agent will monitor and signal for the corresponding physical entity. If the value of this object is ' ...
ceAlarmSeverity
This object specifies the highest severity alarm currently being asserted by the corresponding physical entity. A value of '0' indicates that there the corresponding physical entity currently is not asserting any alarms.
ceAlarmList
This object specifies those alarms currently being asserted by the corresponding physical entity. Note, an alarm indicates a condition, not an event. An alarm has two states: 'asserted' Indicates that the condition described by the alarm exists. 'clear ...
ceAlarmHistTableSize
This object specifies the number of entries that the ceAlarmHistTable can contain. When a physical entity generates an unfiltered alarm, and the capacity of the ceAlarmHistTable has reached the value specified by this object, then the agent deletes the o ...
ceAlarmHistLastIndex
This object specifies the value of the ceAlarmHistIndex object corresponding to the last entry added to the table by the agent. If the management client uses the notifications defined by this module, then it can poll this object to determine whether it ha ...
ceAlarmHistTable
This table contains a history of ceAlarmIndicate and ceAlarmClear traps generated by the agent.
ceAlarmHistEntry
The information conveyed by a ceAlarmIndicate or ceAlarmClear trap.
ceAlarmHistIndex
An integer value uniquely identifying the entry in the table. The value of this object starts at '1' and monotonically increases for each alarm condition transition monitored by the agent. If the value of this object is '4294967295', the agent will reset ...
ceAlarmHistType
This object specifies whether the agent created the entry as the result of an alarm being asserted or cleared.
ceAlarmHistEntPhysicalIndex
This object specifies the physical entity that generated the alarm.
ceAlarmHistAlarmType
This object specifies the type of alarm generated.
ceAlarmHistSeverity
This object specifies the severity of the alarm generated.
ceAlarmHistTimeStamp
This object specifies the value of the sysUpTime object at the time the alarm was generated.
ceAlarmNotifiesEnable
This object specifies a severity threshold governing the generation of ceAlarmAsserted and ceAlarmCleared notifications. For example, if the value of this object is set to 'major', then the agent generates these notifications if and only if the severity ...
ceAlarmSyslogEnable
This object specifies a severity threshold governing the generation of syslog messages corresponding to alarms. For example, if the value of this object is set to 'major', then the agent generates these a syslog message if and only if the severity of the ...
ceAlarmFilterProfileIndexNext
This object contains an appropriate value to be used for ceAlarmFilterIndex when creating entries in the ceAlarmFilterProfileTable. The value '0' indicates that no unassigned entries are available. To obtain a ceAlarmFilterIndex, the management client i ...
ceAlarmFilterProfileTable
This table contains a list of alarm filter profiles.
ceAlarmFilterProfileEntry
When a physical entity asserts/clears an alarm AND the ceAlarmFilterProfile object is not '0', the agent applies the specified alarm filter profile in processing the alarm. The agent uses the following procedure in processing the transition of an alarm co ...
ceAlarmFilterIndex
This object uniquely identifies the alarm filter profile.
ceAlarmFilterStatus
This object facilitates the creation, modification, or deletion of a conceptual row in this table. A management client can create a conceptual row in this table by setting this object to 'createAndWait' or 'createAndGo'. If a request to create a conceptu ...
ceAlarmFilterAlias
This object specifies an arbitrary name associated with the alarm filter profile by the management client, and provides a non-volatile 'handle' for the alarm filter profile. On the first instantiation of an alarm filter profile, the value of this object i ...
ceAlarmFilterAlarmsEnabled
This object specifies a list of alarms that are enabled.
ceAlarmFilterNotifiesEnabled
This object specifies a list of alarms for which notification generation is enabled.
ceAlarmFilterSyslogEnabled
This object specifies a list of alarms for which syslog message generation is enabled.
ceAlarmDescriptionGroup
A collection of managed objects defining the description of alarms.
ceAlarmGroup
A collection of managed objects defining alarm reporting by physical entity.
ceAlarmHistGroup
A collection of managed objects defining alarm logging.
ceAlarmFilterGroup
A collection of managed objects that control the generation of all notifications and syslog messages.
ceAlarmFilterProfileGroup
A collection of managed objects that support alarm filtering.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.

MIBs list