CISCO-MGX82XX-DSX3-BERT-MIB

CISCO-MGX82XX-DSX3-BERT-MIB Download

MIBs list

The MIB Module for BERT (Bit Error Rate Testing) on ds3 interfaces in some of the cards (Service Modules) in MGX products.

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-MGX82XX-DSX3-BERT-MIB

dsx3bertControl
This object controls all the SET operations on this MIB group. noAction : No action is taken. This value can not be written This object contains value noAction(0) just after setting it to delBert(6). acquireBert : Acquire BERT resources. cnfBert ...
dsx3bertResourceStatus
All of bert resources can be used by only one user at a time. This object provides the status of the resources.
dsx3bertOwner
This refers to the user who owns the BERT resources. If the user is a CLI user, then this is username. If it is SNMP Manager, then this would be the ASCII form of the IP address.
dsx3bertUserId
This identifies the user who wants to do a SET operation on this group. This will be compared against bertOwner and access will be given only if it matches. Hence, for every SET request, this object should have a valid value. If the user is a CLI user, th ...
dsx3bertStatus
This object provides the status of BERT in the shelf. The possible values are : inactive (1) : BERT not in progress bertInSync (2) : BERT is activated and receive side is synchronized with the incoming sequence of patterns. bertOutOfSync (3) : ...
dsx3bertTestMedium
Specifies whether the BERT is to be tested on a port or an entire T3/E3 line. For a BERT test, this object must be set. For CESM-T3E3 and FRSM-@T3E3, this object must be set to line(2).
dsx3bertPort
This object specifies the port number for BERT. Port level bert is not supported in CESM-T3E3 and FRSM-2T3E3. So for these cards, the value must be always 1.
dsx3bertLine
This object specifies the line number for BERT. If the dsx3bertTestMedium is set to port(1), this represents the line to which the port (dsx3bertPort) belongs. The value supported depends upon the type of card (service module).
dsx3bertMode
This object specifies the mode, the BERT module is to be configured for. The value loopback(2) is not supported in CESM-T3E3 and FRSM-2T3E3 .
dsx3bertPattern
This variable determines BERT pattern to be transmitted on the interface identified by dsx3bertLine or dsx3bertPort. Bit error measurements are widely used to assess the performance of a digital transmission equipment. Precise error measurement requires ...
dsx3bertLoopback
This object specifies the type of loopback to be established/de-established. The value farEndLoopback(1) is not supported in CESM-T3E3 and FRSM-2T3E3, where the default value for this object shall be 2.
dsx3bertStartTime
This object contains the time at which BERT started. The syntax is hh:mm:ss. The time zone is as configured in the shelf. This object contains zero length string for following values of dsx3bertControl: noAction (0), acquireBert (1), releaseBert (2), c ...
dsx3bertStartDate
This object contains the date on which BERT started. The syntax is yy/mm/dd. This object contains zero length string for following values of dsx3bertControl: noAction (0), acquireBert (1), releaseBert (2), cnfBert (3).
dsx3bertBitCountUpper
This number of bits transmitted is represented in an encoded form as a 64-bit counter. This object gives the upper 31 bits of the 64 bit counter. The 32nd bit is not available.
dsx3bertBitCountLower
This number of bits transmitted is represented in an encoded form as a 64-bit counter. This object gives the lower 31 bits of the 64 bit counter. The 32nd bit is not available.
dsx3bertBitErrorCountUpper
This number of bits received in error is represented in an encoded form as a 64-bit counter. This object gives the upper 31 bits of the 64 bit counter. The 32nd bit is not available.
dsx3bertBitErrorCountLower
This number of bits received in error is represented in an encoded form as a 64-bit counter. This object gives the lower 31 bits of the 64 bit counter. The 32nd bit is not available.
dsx3bertErrorInsertionRate
This object is used for injecting continuous errors into transmitted BERT pattern. The errors are inserted in a BERT pattern sent, in order to do sanity check on receive interface in the event that no bit errors are detected. Injecting errors allows use ...
dsx3bertErrorInjectCount
This shows the number of times error was injected.
dsx3bertCleanupAction
When the BERT has to be stopped or aborted (due to card state changes), this object would give the exact action to take. The bert related changes to the card, then, can be cleaned up. The value metallicLoopdown(3) is not applicable for CESM-T3E3 and FRSM ...
cmDsx3BertConfGroup
The collection of objects which are used for configuring/running BERT on DSX3 interfaces.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.