cpqHeTemperatureThreshold - Compaq Server Health Temperature Threshold - CPQHLTH

MIBs list

cpqHeTemperatureThreshold

Compaq Server Health Temperature Threshold
1.3.6.1.4.1.232.6.2.6.8.1.5

This is the shutdown threshold temperature sensor setting in degrees celsius. This is the temerature in which the sensor will be considered to be in a failed state thus causing the system to be shutdown. If this value cannot be determined by software, then a value of -1 will be returned. Only the Ambient zone type allows setting of the threshold temperature.

Back to CPQHLTH MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqHeTemperatureThreshold with IPHost tools