cpqRackCommonEnclosureTempThreshold - Compaq Rack Common Enclosure Temperature Threshold - CPQRACK

MIBs list

cpqRackCommonEnclosureTempThreshold

Compaq Rack Common Enclosure Temperature Threshold
1.3.6.1.4.1.232.22.2.3.1.2.1.7

This is the threshold temperature sensor setting in degrees celsius. This is the temperature in which the sensor will be considered to be in a tripped state this causing some action to occur depending on the type of the sensor. The action of temperature sensor threshold will be indicated by the cpqRackCommonEnclosureTempType item. If the type is blowout(5), then the temperature sensor will cause the fans to speed up. If the type is caution(9), then the temperature sensor is in a degraded state. If the type is critical(15), then the server will be considered as in a failed state. If this value cannot be determined by software, then a value of -1 will be returned.

Back to CPQRACK MIB page.

IPHost Network monitor uses SNMP for monitoring health and availability of devices and applications in your network. You can send a SNMP Set to any remote device to monitor a specific SNMP object (CPU, Memory, Disk, Server Temperature, RAID failures, IO statistics, connection counts, error and much more).

Easy monitoring of cpqRackCommonEnclosureTempThreshold with IPHost tools