CISCO-DS3-MIB

CISCO-DS3-MIB Download

MIBs list

The MIB module to describe DS3 line objects. This is an extension to the standard DS3 MIB(RFC 2496).

IPHost Network Monitor offer an easy way of SNMP monitoring your Cisco Servers, Routers, Switches, Bridges, Firewalls, Repeaters.

OID list for CISCO-DS3-MIB

cds3ConfigTable
The DS3 Configuration table. The table has objects for configuring a T3/E3 line.
cds3ConfigEntry
An entry in the table. There is an entry for each available T3/E3 line, with an ifType value of 'ds3'(30). By default, lines are disabled. 'ifAdmin' from ifTable must be used to up the line. The objects in this table can be modified only when the line is ...
cds3LineType
This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The values, in sequen ...
cds3LineAIScBitsCheck
When check(1) is set, then Alarm Indication Signal (AIS) is declared when '1010...'b is found and C-Bits are all zero. When ignore(2) is set, an AIS condition is declared when the '1010...'b is detected irrespective of the state of the C-Bits. Does not ap ...
cds3LineRcvFEACValidation
This entry specifies the FEAC (Far End Alarm and Control) code validation criteria. If 'fEACCodes4Of5' is specified, then a valid FEAC code is declared if 4 of 5 codes match. When 'fEACCodes8Of10' is specified, then a valid FEAC code is declared when 8 of ...
cds3LineOOFCriteria
This entry specifies the out of frame(OOF) decision criteria. If 'bits3Of8' is specified then an OOF condition is declared if at least 3 of 8 framing bits are in error. When 'bits3Of16' is specified then OOF is declared if 3 of 16 framing bits are found t ...
cds3TraceToTransmit
Transmitted G.832 Trail Trace string.
cds3TraceToExpect
G.832 Trail Trace string that is expected to be received from the other end.
cds3TraceAlarm
The value of this object is set to traceFailure(2) when DS3 line receives a trace does not match the 'cds3TraceToExpect'.
cds3InternalEqualizer
This variable indicates whether the internal equalizer is being used or bypassed. Set this value depending on the line equipment to which the receiver is attached. Possible values are : use(1) : Use the internal equalizer byPass(2) : bypass interna ...
cds3NearEndLineLoopbackStatus
Indicates the loopback status of the near end DS1 on this DS3 when loopback request is indicated. Following table lists the mapping of Bit position to DS1 or DS3 lines and the value. Bit Position Line number value -------------------------------- ...
cds3AlarmConfigEntry
An entry in the T3/E3 Alarm Configuration Table. The entries are automatically created for an ifType value of 'ds3'(30), with default values for objects. Thresholds may be configured for: Line Code Violations(LCV), LineErrored Seconds(LES), Line Severely ...
cds3NEAlarmUpCount
This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decre ...
cds3NEAlarmDownCount
This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The Default value is 1 and the integration counter is decremented by this value every 10 ms while no alarm persists. The counter is incremented ...
cds3NEAlarmThreshold
The value set in this object determines the value that the alarm integration counter must reach for an near end alarm to be declared. If the up count is 6, and the threshold 150, an Alarm is integrated in 2.5 seconds. If the down count is 1, then alarm wi ...
cds3FEAlarmUpCount
This parameter specifies the increment to the Far End alarm integration counters. The alarms are Remote Alarm Indication (RAI) and Alarm Indication Signal(AIS). The integration counter is incremented by this value every 10 ms while the alarm persists. Th ...
cds3FEAlarmDownCount
This parameter specifies the decrement to the Far End alarm integration counters. The alarms are Alarm Indication Signal (AIS) and Remote Alarm Indication (RAI). The integration counter is decremented by this value every 10 ms (till zero), while no alarm ...
cds3FEAlarmThreshold
The value set in this object determines the value that the alarm integration counter must reach for an far end Alarm to be declared. If the up count is 6, the down count is 1 and the threshold 150, an Alarm is integrated in 2.5 sec and removed in 15 secon ...
cds3StatisticalAlarmSeverity
This variable is used to setup the severity of any of the Statistical alarms. So when a Statistical Counter exceeds its specified threshold the system will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised ...
cds3LCV15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3LCV24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
cds3LES15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3LES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
cds3PCV15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
cds3PCV24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
cds3PES15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
cds3PES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
cds3PSES15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
cds3PSES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
cds3SEFS15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3SEFS24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval
cds3UAS15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3UAS24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval
cds3CCV15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
cds3CCV24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval. Not for E3.
cds3CES15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
cds3CES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3.
cds3CSES15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared. Not for E3.
cds3CSES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. Not for E3.
cds3LSES15MinThreshold
Used to set the 15 minute threshold for LSES(Line Severely Errored Seconds). The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3LSES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared.
cds3LineStatisticalAlarmState
This is a bitmap of the DS3 Line Statistical alarms. It is represented as a sum where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. Zero indicates no alarms. Itemized below are the individual alarm bits: BitPosition ...
cds3StatsTable
T3/E3 Statistics table. This table maintains the number of times the line encountered Loss of Signal(LOS), out of frame(LOF), Alarm Indication signals(AIS), Remote alarm indications(RAI), C-bit coding violations(CCV), Framing Errors(FE), from the time it ...
cds3StatsEntry
An entry in the T3/E3 Statistics table. Statistics are gathered for each existing T3/E3 line. An entry is created automatically for each T3/E3 line that is activated.
cds3RcvLOSCount
The number of times Loss of Signal was detected with or without integrating to LOS alarm.
cds3RcvOOFCount
The number of times Out of Frame was detected with or without integrating to OOF alarm.
cds3RAICount
The number of timesRemote Alarm Indication was detected with or without integrating to RAI alarm.
cds3CCVCount
The counter associated with the number of C-Bit Coding Violations encountered by a T3/E3 interface.
cds3FECount
The number of Framing Errors encountered by a T3/E3 interface.
cds3EXZSCount
The number of Excessive Zeros(EXZ) by a T3/E3 interface. An EXZ is the occurrence of any string of zeros having length equal to or greater than 3 for B3ZS, or any string of zeros having length greater than 4 for HDB3.
cds3LCVCount
The count of both BPVs(Bipolar Violations) and EXZs(Excessive Zeros) encountered by a T3/E3 interface.An EXZ increments the LCV by one regardless of the length of the zero string.
cds3PCVCount
This is the count of P-bit Coding Violation(PCV) error event encountered by DS3 interface. For all DS3 applications, a coding violation error event is a P-bit Parity Error(PERR) event. The parity errors occur when the calculated parity in the information ...
cds3CPECount
The number of C-bit parity errors(CPERR) on a DS3 interface. This value is calculated over noninformation bits in the DS3 frame.
cds3FEBECount
The number of Far End Block Errors(FEBE) encountered by a T3/E3 interface.These include frame alignment errors, multiframe alignment errors, and C-bit parity errors. These errors are generated by the transmitter at the far end, and indicate that the trans ...
cds3RcvAISCount
The number of times Alarm Indication Signals(AIS) were detected. The AIS indicates that an upstream failure has been detected by the far end.
cds3AlarmConfigPlcpTable
The ATM interface PLCP alarm configuration table. PLCP is a sublayer over the DS3 interface, that carries ATM cells.
cds3AlarmConfigPlcpEntry
An entry in the DS3 PLCP Alarm Configuration table. The entries contain parameters to configure DS3 PLCP error statistics thresholds, so that an alarm is raised whenever any threshold is exceeded. The entries are automatically created for active DS3 inter ...
cds3PlcpStatisticalAlarmSeverity
This variable sets up the severity of PLCP Statistical alarm. So when PLCP Statistical alarm is detected the module will send the alarm with appropriate severity. A value of none(3) indicates that no alarm will be raised.
cds3PlcpBip8CV15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3PlcpBip8CV24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
cds3PlcpBip8ES15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3PlcpBip8ES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
cds3PlcpBip8SES15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3PlcpBip8SES24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
cds3PlcpSEFS15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3PlcpSEFS24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
cds3PlcpUAS15MinThreshold
The value set in this object determines the value which when exceeded in a 15 minute window causes a statistical alarm to be declared.
cds3PlcpUAS24HrThreshold
The value set in this object determines the value which when exceeded in a sliding 24 hour window causes a statistical alarm to be declared. The threshold is checked every 15 minutes for the preceding 24 hour interval.
cds3AlarmPlcpTable
The Plcp interface alarm table. This table maintains the CV,ES,SES, SEFS and UAS for DS3 line with Plcp framing selected. Please refer to RFC2496 for description of these various error statistics.
cds3AlarmPlcpEntry
An entry in the DS3 Plcp Alarm table. Bucket statistics(15 minute and 24 hour interval statistics) are gathered for each existing DS3 line with PLCP frame format selected. An entry is created automatically and is indexed by the DS3 line number.
cds3PlcpLineAlarmState
This variable is a bitmap of the DS3 Line ALarms. It is represented as sum where value 2^(N-1) is added to the sum if alarm corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are the individual bits: Bi ...
cds3PlcpLineStatisticalAlarmState
This variable is a bitmap of the DS3 Plcp Line Statictical Alarms. It is represented as a sum, where value 2^(N-1) is added to the sum if threshold corresponding to bit N is exceeded. A value of zero for this object indicates no alarms. Itemized below are ...
cds3PlcpBip8CVCurrent
The number of BIP-8 code violations (CV) encountered by the line in the current 15 minute period.
cds3PlcpBip8CV24HrBucket
The number of BIP-8 CVs encountered by the line in the last 24 hours.
cds3PlcpBip8ESCurrent
The number of BIP-8 Errored Seconds(ES) encountered by the line in the current 15 minute period.
cds3PlcpBip8ES24HrBucket
The number of BIP-8 ES encountered by the line in the last 24 hour.
cds3PlcpBip8SESCurrent
The number of BIP-8 Severely Errored Seconds(ES) encountered by the line in the current 15 minute period.
cds3PlcpBip8SES24HrBucket
The number of BIP-8 SES encountered by the line in the last 24 hour.
cds3PlcpSEFSCurrent
The number of BIP-8 Severely Errored Framing Seconds(SEFS) encountered by the line in the current 15-minute period.
cds3PlcpSEFS24HrBucket
The number of BIP-8 SEFS encountered by the line in the last 24 hour.
cds3PlcpUASCurrent
The number of Unavailable Seconds(UAS) encountered by the line in the current 15-minute period.
cds3PlcpUAS24HrBucket
The number of BIP-8 UAS encountered by the line in the last 24 hour.
cds3PlcpStatsTable
T3 Plcp Statistics table. This table maintains the errors encountered by the T3 line with Plcp frame format selected, from the time the line is up.Line fails and goes down as a result of failures. When the line is brought back up again by the user after ...
cds3PlcpStatsEntry
An entry in the T3 Plcp Stats table. Statistics are gathered for each existing T3 line with PLCP frame format selected. An entry is created automatically and is indexed by the T3 line number.
cds3PlcpRcvBip8Count
The number of of BIP-8 errors encountered by the line.
cds3PlcpRcvOOFCount
The number of times Out of Frame(OOF) was detected with or without integrating to OOF alarm.
cds3PlcpRcvRAICount
The number of times Remote Alarm Indication(RAI) was detected with or without integrating to RAI alarm.
cds3PlcpFECount
The number of Framing Errors detected.
cds3PlcpFESecCount
The number of Framing Error errored seconds.
cds3PlcpSEFSecCount
The number of Severely errored Framing error seconds.
cds3PlcpFEBECount
The count of Far End Block Errors (FEBE) detected.
cds3PlcpFEBESecCount
The number of FEBE errored seconds.
cds3PlcpSEFEBESecCount
The number of Severely errored FEBE seconds.
cds3IntervalTable
The DS3 interface interval table.
cds3IntervalEntry
An entry in the T3/E3 current interval table.
cds3IntervalNumber
A number between 0 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minute interval completed 23 hours and 45 minutes prior to interval number 1. Interval number 0 refers to the current 15 minute data.
cds3IntervalLSESs
The number of LSESs encountered by the line in 15 minute interval.
cds3Current24HrTable
The DS3 interface current 24 hour table. This table contains counters for current 24 hour interval. Threshold on this counters are configured through cds3AlarmConfigTable table. 24 hour interval is aligned to wall clock.
cds3Current24HrEntry
An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of 'ds3'(30), when interface is made active.
cds3LCVCurrent24Hr
The number of LCVs encountered by the line since the start of current 24 hour period.
cds3LESCurrent24Hr
The number LESs encountered by the line since the start of current 24 hour period.
cds3PCVCurrent24Hr
The number PCVs encountered by the line since the start of current 24 hour period.
cds3PESCurrent24Hr
The number of PESs encountered by the line since the start of current 24 hour period.
cds3PSESCurrent24Hr
The number of PSESs encountered by the line since the start of current 24 hour period.
cds3SEFSCurrent24Hr
The number of SEFSs encountered by the line since the start of the current 24 hour period.
cds3UASCurrent24Hr
The number of UASs encountered by the line since the start of current 24 hour period.
cds3CCVCurrent24Hr
The number CCVs encounterd by the line since the start of current 24 hour period.
cds3CESCurrent24Hr
The number of CESs encountered by the line since the start of current 24 hour period.
cds3CSESCurrent24Hr
The number of CSESs encountered by the line since th start of current 24 hour period.
cds3LSESCurrent24Hr
The number of LSESs (Line severedly errored seconds) encountered by the line since the start of current 24 hour period.
cds3Previous24HrTable
The DS3 interface previous 24 hour table. This table contains counters for previous 24 hour interval. Implementation of this table is optional.
cds3Previous24HrEntry
An entry in the T3/E3 current 24 hour counter table. The entries are automatically created for an ifType value of ds3(30), when interface is made active.
cds3LCVPrevious24Hr
The number of LCVs encountered by the line in the previous 24 hour period.
cds3LESPrevious24Hr
The number LESs encountered by the line in the previous 24 hour period.
cds3PCVPrevious24Hr
The number PCVs encountered by the line in the previous 24 hour period.
cds3PESPrevious24Hr
The number of PESs encountered by the line in the previous 24 hour period.
cds3PSESPrevious24Hr
The number of PSESs encountered by the line in the previous 24 hour period.
cds3SEFSPrevious24Hr
The number of SEFSs encountered by the line in the start of the current 24 hour period.
cds3UASPrevious24Hr
The number of UASs encountered by the line in the previous 24 hour period.
cds3CCVPrevious24Hr
The number CCVs encounterd by the line in the previous 24 hour period.
cds3CESPrevious24Hr
The number of CESs encountered by the line in the previous 24 hour period.
cds3CSESPrevious24Hr
The number of CSESs encountered by the line in the previous 24 hour period.
cds3LSESPrevious24Hr
The number of LSESs encountered by the line in the previous 24 hour period.
ciscoDs3ConfMIBGroup
Collection of DS3/E3 line related configuration parameters.
cds3StatsMIBGroup
Collection of DS3/E3 line related real time counters.
ciscoDs3AlarmMIBGroup
Collection of DS3/E3 related interval counters and threshold parameters.
ciscoPlcpCounterMIBGroup
Collection of PLCP related real time counters.
ciscoPlcpAlarmMIBGroup
Collection of PLCP related interval counters and threshold parameters.
ciscoDs3Previous24HrGroup
A collection DS3/E3 related previous 24 hour counters.

Download IPHost Network Monitor (500 monitors for 30 days, 50 monitors free forever) to start monitoring network devices right now.