The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for alarm count
- ds1 Alarm Global ES Count
- ds1AlarmGlobalESCount 1.3.6.1.4.1.52.4.1.2.7.2.8.1.4 (defined in ctron-remote-access-mib)
Used in conjuction with ctDs1AlarmESInterval to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval. - ds1 Alarm ES Count
- ds1AlarmESCount 1.3.6.1.4.1.52.4.1.2.7.2.8.2.1.5 (defined in ctron-remote-access-mib)
Used in conjuction with ctDs1AlarmESInterval to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval. - ds1 Alarm ES Count
- ds1AlarmESCount 1.3.6.1.4.1.52.4.1.2.7.2.8.2.1.5 (defined in ctron-wan-mib)
Used in conjuction with ctDs1AlarmESInterval to set the threshold for alarm generation when the number of Errored Seconds for a specified time interval, measured in minutes, is exceeded. The default Errored Seconds alarm condition is 100 errored seconds over a 6 minute time interval. - Cabletron Wan HDSL Alarm History LLOS Count
- ctWanHDSLAlHistLLOSCount 1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.5 (defined in ctron-wan-mib)
Number of times the DS1 Loss Of Signal (LOS) occurred since we last cleared the alarm history on the local side of the HDSL. (HiGain only) - Cabletron Wan HDSL Alarm History LOSW2 Count
- ctWanHDSLAlHistLOSW2Count 1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.17 (defined in ctron-wan-mib)
Number of times the Loss Of Sync Word (LOSW) occurred since we last cleared the history on the LOOP 2 of the HDSL link. - Cabletron Wan HDSL Alarm History ES1 Count
- ctWanHDSLAlHistES1Count 1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.21 (defined in ctron-wan-mib)
Number of times the Errored Seconds (ES) occurred since we last cleared the alarm history on the LOOP 1 of the HDSL link. - Cabletron Wan HDSL Alarm History Margin2 Count
- ctWanHDSLAlHistMargin2Count 1.3.6.1.4.1.52.4.1.2.7.1.8.6.1.33 (defined in ctron-wan-mib)
Number of times the alarm exceeded the Margin Threshold since we last cleared the alarm history on the LOOP 2 of the HDSL link. - Cisco Content Engine Alarm Critical Count
- cceAlarmCriticalCount 1.3.6.1.4.1.9.9.178.1.6.2.1 (defined in CISCO-CONTENT-ENGINE-MIB)
The value of this object specifies the number of alarms currently raised with a severity of 'critical'. - Cisco Content Engine Alarm Major Count
- cceAlarmMajorCount 1.3.6.1.4.1.9.9.178.1.6.2.2 (defined in CISCO-CONTENT-ENGINE-MIB)
The value of this object specifies the number of alarms currently raised with a severity of 'major'. - Cisco Content Engine Alarm Minor Count
- cceAlarmMinorCount 1.3.6.1.4.1.9.9.178.1.6.2.3 (defined in CISCO-CONTENT-ENGINE-MIB)
The value of this object specifies the number of alarms currently raised with a severity of 'minor'. - Cisco DS1/E1 Alarm Up Count
- cds1AlarmUpCount 1.3.6.1.4.1.9.9.229.1.2.2.1.3 (defined in CISCO-DS1-EXT-MIB)
This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The integration counter is incremented by this value every 100 ms while the alarm persists. When the integration counter exceeds 'cds1AlarmThreshold' an Alarm of the severity specified for the particular alarm is declared. The integration counter is an internal counter specific to the implementation and dictates the slope of integration. - Cisco DS1/E1 Alarm Down Count
- cds1AlarmDownCount 1.3.6.1.4.1.9.9.229.1.2.2.1.4 (defined in CISCO-DS1-EXT-MIB)
This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The integration counter is decremented by this value every 100 ms while no alarm persists. The counter does not decrement below zero. When the integration counter reaches zero any Alarm previously declared is removed. - Cisco DS3 NE Alarm Up Count
- cds3NEAlarmUpCount 1.3.6.1.4.1.9.9.132.1.2.1.1.1.1 (defined in CISCO-DS3-MIB)
This parameter specifies the increment to the Near End alarm integration counters. The local alarms are LOS and LOF. The Default value is 6 and the integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by the value of 'cds3NEAlarmDownCount' while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds 'cds3NEAlarmThreshold' an Alarm of the severity specified for the particular Near End alarm is declared. - Cisco DS3 NE Alarm Down Count
- cds3NEAlarmDownCount 1.3.6.1.4.1.9.9.132.1.2.1.1.1.2 (defined in CISCO-DS3-MIB)
This parameter specifies the decrement to the Near End alarm integration counters. The alarms are LOS and LOF. The Default value is 1 and the integration counter is decremented by this value every 10 ms while no alarm persists. The counter is incremented by the value of cds3NEAlarmUpCount while there is no alarm (the counter does not decrement below zero). When the integration counter reaches zero any Alarm previously declared is removed. - Cisco DS3 FE Alarm Up Count
- cds3FEAlarmUpCount 1.3.6.1.4.1.9.9.132.1.2.1.1.1.4 (defined in CISCO-DS3-MIB)
This parameter specifies the increment to the Far End alarm integration counters. The alarms are Remote Alarm Indication (RAI) and Alarm Indication Signal(AIS). The integration counter is incremented by this value every 10 ms while the alarm persists. The counter is decremented by this value while there is no alarm (the counter does not decrement below zero). When the integration counter exceeds cds3FEAlarmThreshold an Alarm of the severity specified for the particular far end alarm is declared. - Cisco DS3 FE Alarm Down Count
- cds3FEAlarmDownCount 1.3.6.1.4.1.9.9.132.1.2.1.1.1.5 (defined in CISCO-DS3-MIB)
This parameter specifies the decrement to the Far End alarm integration counters. The alarms are Alarm Indication Signal (AIS) and Remote Alarm Indication (RAI). The integration counter is decremented by this value every 10 ms (till zero), while no alarm persists. The counter is incremented by this value while there is no alarm. When the integration counter decrements to zero any previously declared Alarm is removed. - Cisco Entity Alarm Critical Count
- ceAlarmCriticalCount 1.3.6.1.4.1.9.9.138.1.2.1 (defined in CISCO-ENTITY-ALARM-MIB)
The value of this object specifies the number of alarms currently asserted with a severity of 'critical'. - Cisco Entity Alarm Major Count
- ceAlarmMajorCount 1.3.6.1.4.1.9.9.138.1.2.2 (defined in CISCO-ENTITY-ALARM-MIB)
The value of this object specifies the number of alarms currently asserted with a severity of 'major'. - Cisco Entity Alarm Minor Count
- ceAlarmMinorCount 1.3.6.1.4.1.9.9.138.1.2.3 (defined in CISCO-ENTITY-ALARM-MIB)
The value of this object specifies the number of alarms currently asserted with a severity of 'minor'.