OIDs - poll_time
The objects described here can be monitored with the IPHost Network Monitor.
You can start SNMP monitoring using free 30-day trial version of IPHost right now.
OID list for "poll time"
- Compaq Drive Array Nw3x Poll Time
- cpqDaNw3xPollTime 1.3.6.1.4.1.232.3.2.1.1.4 (defined in CPQIDA)
Compaq Array Controller Driver Interface Poll Time. If the Poll Type is Polled, this value shows how frequently, in seconds, the instrument agent requests Information from the device driver. For example, if the Poll Type is Polled and the Poll Time is two, the instrument agent will poll the device driver every two seconds. To change the Poll Time for NetWare, unload and then reload the instrument agent using the following commands: UNLOAD CPQDSKSA LOAD CPQDSKSA [/Un] The parameter /U specifies the frequency of updates in seconds. The variable n represents the number of seconds that the NLM should wait before collecting new data. The minimum value is one second. The maximum value is 300 seconds (five minutes). - Compaq Scsi Nw3x Driver Poll Time
- cpqScsiNw3xDriverPollTime 1.3.6.1.4.1.232.5.2.1.1.4 (defined in CPQSCSI)
Compaq SCSI Drive Device Driver Poll Time. If the nw3xDriverPollType is polled(2) this value shows how frequently, in seconds, the instrument agent requests information from the device driver. To change the poll time, you need to unload and then reload the instrument agent using the following commands: UNLOAD CPQDSKSA LOAD CPQDSKSA /U - vlan System First Poll Time
- vlanSystemFirstPollTime 1.3.6.1.4.1.52.4.2.12.1.2.5.1.1.12 (defined in ctron-sfps-vlan-mib)
System time when first polled - vlan System Last Poll Time
- vlanSystemLastPollTime 1.3.6.1.4.1.52.4.2.12.1.2.5.1.1.13 (defined in ctron-sfps-vlan-mib)
Last time polled - vlan System Prior Poll Time
- vlanSystemPriorPollTime 1.3.6.1.4.1.52.4.2.12.1.2.5.1.1.14 (defined in ctron-sfps-vlan-mib)
Poll time one before the last poll time - vlan System Delta Poll Time
- vlanSystemDeltaPollTime 1.3.6.1.4.1.52.4.2.12.1.2.5.1.1.15 (defined in ctron-sfps-vlan-mib)
Time difference between last poll time and prior poll time - Cisco CDS-TV ISA Config Service Poll Time
- cdstvISAConfigServicePollTime 1.3.6.1.4.1.9.9.755.1.1.8 (defined in CISCO-CDSTV-ISA-MIB)
This object specifies the time interval (seconds) between polling for orphan sessions. - Cisco CMTS Remote Query Cmts Cable Modem Poll Time
- cdrqCmtsCmPollTime 1.3.6.1.4.1.9.10.59.1.2.1.1.6 (defined in CISCO-DOCS-REMOTE-QUERY-MIB)
The value of sysUpTime when this CM entry was polled. If this value is larger than the cdrqCmtsCmPollerStopTime, either by receiving it from the cdrqCmtsCmRQDoneNotification or by polling the object itself, it indicates that the status has already been overwritten by a new polling cycle. To avoid this to happen, the NMS can increase the cdrqCmtsCmPollInterval so that the cdrqCmtsCmPollTime would fall in between the cdrqCmtsCmPollerStartTime and the cdrqCmtsCmPollerStopTime.